Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power provides exact-part review, quotations, technical documents, and DeltaV integration guidance.

KC3011X1-BA1 12P6749X042

/ 4.9
1001 reviews | Need a Specific Revision?
Emerson KC3011X1-BA1 12P6749X042 is a DeltaV AO Plus module providing 16 channels of 4–20 mA HART output.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for KC3011X1-BA1 12P6749X042
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for KC3011X1-BA1 12P6749X042

  • Manufacturer:
    Emerson
  • Part Number:
    KC3011X1-BA1 12P6749X042
  • Product Family:
    DeltaV
  • Product Type:
    DeltaV AO Plus 16-Channel 4–20 mA HART Module
  • Stock:
    1
  • Product role:
    AO Plus 16-channel 4–20 mA HART
  • Local bus power:
    12 VDC at 160 mA
  • Field power:
    24 VDC at 400 mA
  • Field circuit:
    17 VDC at 23 mA per channel
  • Terminal-block key:
    A5
  • Ambient temperature:
    -40 to +70 °C
  • Weight:
    0.18 kg
  • Estimated shipping dimensions:
    4.1x12.5x10.4cm
  • Tariff Code:
    8538900000
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Signal Scope Power Entries Environment and Keying Product Applications

Features:

  • Output role: Delivers DeltaV AO Plus 4–20 mA HART commands through sixteen channels.
  • Power relationship: Both local-bus and field-power arrangements affect installation.
  • Terminal match: The A5 keying and full KC/12P identity govern module selection.
The module converts assigned DeltaV outputs into documented field-current loops.

Local-bus and field-power requirements must both be satisfied.

Full KC and 12P identity controls sourcing and receiving inspection.

Apter Power can support quotations and technical-document requests for the Emerson KC3011X1-BA1 12P6749X042 DeltaV AO Plus Module.
Emerson KC3011X1-BA1 12P6749X042 DeltaV AO Plus Module Manuals,Datasheets,LinkImportant Notice: Terminal blocks, field power supplies, loop wiring and HART instruments are excluded unless quoted.
  • Output function: Sixteen current-loop channels carry assigned DeltaV commands to field devices.
  • HART path: The documented output circuits support HART communication as part of the loop design.
  • Circuit planning: Emerson power specifications should be compared with each field load.
  • Project mapping: Channel scaling and assignments must agree with the deployed DeltaV configuration.
  • Local bus: The card draws 12 VDC at 160 mA from the documented bus supply.
  • Field supply: The 24 VDC at 400 mA requirement belongs to the output-side power design.
  • Loop margin: Field-circuit capability should be checked against connected device requirements before commissioning.
  • Mismatch response: A supply discrepancy calls for engineering review before the output loops are energized.
  • Terminal pairing: The A5 key position helps prevent a mismatched terminal block from being fitted.
  • Operating setting: The documented ambient range should be considered with cabinet temperature.
  • Hazardous-area handling: Emerson states this card must not be removed or inserted while system power is energized.
  • Installation reference: The applicable DeltaV Zone 2 instruction sheet governs the approved handling procedure.
  • DeltaV process-control analog outputs.
  • 4–20 mA actuator and positioner command loops.
  • HART-capable output-channel maintenance.
  • Exact-part replacement in keyed DeltaV carriers.
Description
Emerson identifies KC3011X1-BA1 12P6749X042 as a DeltaV AO Plus card for sixteen 4–20 mA HART output channels. It translates assigned controller outputs into field current loops through the approved terminal arrangement.

The A5 key position and separate local-bus and field-power requirements of KC3011X1-BA1 12P6749X042 are practical selection checks. They connect the exact card to its carrier, terminal block and installed loop-power design, beyond matching the front label alone.

For hazardous-area work, Emerson states that KC3011X1-BA1 12P6749X042 must not be inserted or removed while system power is energized. Apter Power can help source the exact assembly and provide the instruction sheet for a site-approved maintenance plan.
Alternative Names
Emerson KC3011X1-BA1 12P6749X042 KC3011X1-BA1 12P6749X042 KC3011X1BA1 12P6749X042 KC3O11X1-BA1 12P6749X042 KC301IX1-BA1 12P6749X042 KC3011X1-BAI 12P6749X042 KC3011X1-BA1 12P6749X04Z
Technical notes
KC3011X1-BA1 12P6749X042 is keyed for the documented AO Plus 16-channel 4–20 mA HART application. Check A5 terminal-block keying, 12 VDC local-bus power, 24 VDC field power and every loop assignment before installation. Do not insert or remove it energized in a hazardous area.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which terminal-block key should match KC3011X1-BA1 12P6749X042?
Emerson specifies A5 keying for this AO Plus card. Please compare the installed terminal block and carrier before selecting a replacement.
Can KC3011X1-BA1 12P6749X042 replace a standard analog output card?
Not on channel count alone. HART capability, keying, power arrangements and the DeltaV project should all be compared first.
What supplies should be checked for KC3011X1-BA1 12P6749X042?
Emerson documents separate local-bus and field-power requirements. Our team can help locate the instruction sheet for a review against your cabinet supply design.
May KC3011X1-BA1 12P6749X042 be inserted with system power on?
Emerson states this unit cannot be removed or inserted while system power is energized. Plan the exchange under the applicable site and Zone 2 procedures.
How can I confirm the loops after fitting KC3011X1-BA1 12P6749X042?
Verify the intended channel assignment, output current and HART communication where used, then confirm the final control response under the approved test plan.
What details should accompany an enquiry for KC3011X1-BA1 12P6749X042?
Send both KC and 12P markings, a terminal-block photo and the installed carrier information so Apter Power can review exact-part fit and quote accurately.

Product Browsing History