Features:
- Redundant Profibus DP interface is the documented terminal role for KJ3243X1-EA1 as this redundant Profibus DP terminal block.
- KJ3243X1-EA1 operates within the documented -40 to 70 degrees C temperature range for this redundant Profibus DP terminal block.
- KJ3243X1-EA1 supports 5 to 95%, non-condensing relative humidity for the documented redundant Profibus DP terminal block.
The current ordering configuration is KJ3243X1-EA1, the DeltaV Redundant Profibus DP Terminal Block identified for the DeltaV M-series Profibus DP.
KJ3243X1-EA1 performs the documented redundant Profibus DP terminal block function within the DeltaV Profibus DP interface hardware architecture. Its operation follows the capabilities and limits assigned to this exact ordering configuration.
Before commissioning, match both Profibus cards, preserve bus termination and shield wiring, and remove power before terminal replacement.
Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Emerson KJ3243X1-EA1:
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Terminate the two interface cards used in a redundant DeltaV Profibus DP assembly.
- Provide the fieldbus wiring connection for a matched redundant Profibus DP interface configuration.
- Support high-availability Profibus DP device communication when installed with the specified interface cards and carrier.
- Match KJ3243X1-EA1 to the exact carrier, terminal, and I/O hardware documented for its DeltaV Profibus DP interface hardware installation.
- KJ3243X1-EA1 uses a Redundant terminal configuration redundancy arrangement for this redundant Profibus DP terminal block.
- Remove power before terminal replacement before placing KJ3243X1-EA1 in service.
- Install KJ3243X1-EA1 only with the carrier, terminal, and field-wiring components documented for this redundant Profibus DP terminal block.
- Verify keying, circuit ratings, and power isolation before connecting or removing KJ3243X1-EA1.
- Complete the documented wiring checks before placing the KJ3243X1-EA1 assembly in service.
- Apply the documented power-removal and hazardous-area precautions before servicing KJ3243X1-EA1.
- Verify field-circuit ratings and the defined safe-state behavior for this redundant Profibus DP terminal block.
- KJ3243X1-EA1 has a documented storage-temperature range of -40 to 85 degrees C for this redundant Profibus DP terminal block.