Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power supports KL2002X1-BB1 capacity review, quotation and controller-scope sourcing.

KL2002X1-BB1

/ 4.9
1001 reviews | Need a Specific Revision?
Emerson KL2002X1-BB1 is the DeltaV PK300 controller, providing 300 DST capacity for standalone or integrated process control with native industrial Ethernet connectivity.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for KL2002X1-BB1
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for KL2002X1-BB1

  • Manufacturer:
    Emerson
  • Part Number:
    KL2002X1-BB1
  • Product Family:
    DeltaV
  • Product Type:
    DeltaV PK300 Controller
  • Stock:
    1
  • Controller Capacity:
    300 DST
  • Ethernet Devices on P01:
    32
  • PROFINET Devices:
    100 with v15.FP1/FP2; 250 with v15.FP3 or later
  • Standalone Batch Units:
    4
  • Module Execution Rates:
    25 ms to 60 s
  • Native Protocols:
    Modbus TCP, EtherNet/IP, PROFINET controller, OPC UA Server
  • Carrier Input:
    24 VDC ±10% at 350 mA maximum
  • Power Dissipation:
    7.5 W simplex; 15 W redundant
  • Ambient Temperature:
    -40°C to +60°C
  • Protection Rating:
    IP20, NEMA 12
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Controller Capacity Industrial Ethernet System Architecture Product Applications

Features:

  • PK300 capacity: Provides 300 DST and four standalone batch units for mid-sized control applications.
  • Native networking: Provides OPC UA and Modbus TCP server functions, with project-specific P01 client or scanner and integrated PROFINET options.
  • Flexible deployment: Operates as a standalone controller or an integrated DeltaV system node.
KL2002X1-BB1 executes DeltaV control logic from process signals received through local I/O, CHARMs, wireless I/O and Ethernet devices.

Its PK300 capacity creates a practical middle point between compact packaged-equipment control and larger plant nodes, with module execution rates available from 25 ms to 60 seconds.

Built-in industrial Ethernet services and support for simplex or redundant node designs let KL2002X1-BB1 scale from an independent skid to a distributed DeltaV architecture.

For KL2002X1-BB1 DeltaV PK300 Controller sourcing, Apter Power can help confirm the Emerson capacity, carrier, power and software scope.
Emerson KL2002X1-BB1 DeltaV PK300 Controller Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • DST limit: 300 device signal tags.
  • Ethernet devices: Up to 32 devices on port P01.
  • PROFINET scale: Up to 100 devices with v15.FP1/FP2 or 250 with v15.FP3 and later.
  • Standalone batching: Supports four standalone batch units.
  • Modbus TCP: Native server service is included; P01 can run the client when EtherNet/IP Scanner is not selected.
  • EtherNet/IP: P01 can run Scanner service instead of Modbus TCP Client, not at the same time.
  • PROFINET: Controller service requires integrated DeltaV operation with the applicable version and license.
  • OPC UA: Includes an OPC UA Server for real-time data access.
  • Standalone operation: Runs packaged or remote equipment without a separate DeltaV controller tier.
  • Integrated operation: Joins a wider DeltaV system as a controller node.
  • I/O expansion: Supports local traditional I/O carriers plus electronic and wireless marshalling options.
  • Node redundancy: A second adjacent controller can form a redundant node when the required hardware is installed.
  • Packaged process skids: Combines standalone control, batching and industrial Ethernet in one controller platform.
  • Remote process units: The environmental range and distributed I/O options support installation close to equipment.
  • DeltaV expansion: Adds a 300-DST controller node to plant-wide DeltaV architectures.
  • Mixed I/O projects: Coordinates traditional I/O, CHARMs, WirelessHART I/O and Ethernet devices within one control application.
Description
KL2002X1-BB1 is the PK300 member of the DeltaV PK Controller family, sized for 300 device signal tags and four standalone batch units. It gives skid builders and process-package suppliers enough controller capacity for a substantial local application while preserving a direct path into a wider DeltaV system.

KL2002X1-BB1 combines control execution with native OPC UA Server and Modbus TCP Server services. On P01, projects select either Modbus TCP Client or EtherNet/IP Scanner; PROFINET controller service is reserved for integrated DeltaV operation with the applicable version and license. Six built-in Ethernet ports help consolidate control and communications around distributed process equipment.

KL2002X1-BB1 can operate as a standalone controller or as an integrated DeltaV node, allowing the same controller platform to serve packaged equipment, remote process areas or plant-wide control expansion. G3 conformal coating and a -40°C to +60°C operating range support cabinet installation close to industrial equipment.
Alternative Names
KL2002X1-BB1 KL2002X1 BB1 KL2002X1BB1 Emerson KL2002X1-BB1 DeltaV PK300
Technical notes
KL2002X1-BB1 is the PK300 controller spare, not a complete assembly. It requires a PK carrier, dedicated bulk power, and PK Controller Engineering Software or DeltaV software. P01 can run Modbus TCP Client or EtherNet/IP Scanner—not both; PROFINET requires integrated DeltaV operation with the applicable version and license. Standalone system compatibility is DeltaV v15.LTS.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How much control capacity does KL2002X1-BB1 provide?
The PK300 controller supports 300 device signal tags and four standalone batch units. Use those limits together with module complexity and scan rates when sizing the application.
Can KL2002X1-BB1 run a packaged skid without a plant-wide DeltaV system?
Yes. It can operate as a standalone controller, and the same node can also be integrated into a wider DeltaV architecture when the project expands.
Which industrial Ethernet protocols are native to KL2002X1-BB1?
Native services include OPC UA Server and Modbus TCP Server. On P01, use either Modbus TCP Client or EtherNet/IP Scanner; they cannot run simultaneously. PROFINET controller service is unavailable in standalone operation and requires the applicable integrated DeltaV version and license.
What supporting hardware is required before installing KL2002X1-BB1?
Provide a PK Controller carrier and a dedicated system bulk power supply. Also confirm the required engineering software and whether the node is simplex or redundant.
How should a buyer distinguish KL2002X1-BB1 from the PK750 controller?
BB1 is the PK300 order code with 300 DST; BC1 is the PK750 order code with 750 DST. They are different Emerson order codes, so select by the required capacity and exact controller identity rather than treating the suffixes as aliases.
What installation environment suits KL2002X1-BB1?
The controller is specified for -40°C to +60°C, 5% to 95% non-condensing humidity and G3 airborne-contaminant service. Its published protection ratings are IP20 and NEMA 12.