Features:
- Dual bulk-power inputs: Accepts either 12 VDC or 24 VDC plant power.
- Multi-rail output: Supplies +12 VDC, +5 VDC and +3.3 VDC for DeltaV system electronics.
- Integrated supervision: Provides status LEDs and a normally open alarm relay.
VE5109 is the ordered M-series DC to DC system power supply used to feed a DeltaV controller and I/O-interface power buses.
Its carrier connection keeps the power path modular while the specified input and output ranges let engineers calculate capacity for the actual bulk-power source.
Visible indicators and the alarm contact separate incoming-power and output-tolerance checks from broader controller diagnostics.
For Emerson VE5109 M-series DC to DC System Power Supply sourcing, Apter Power can help confirm carrier, load and quotation requirements.
Emerson VE5109 M-series DC to DC System Power Supply Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Bulk-source choice: Match VE5109 to either the documented 12 VDC or 24 VDC source and size upstream capacity for that selected input mode.
- Main-rail capacity: Available +12 VDC current changes with bulk-input choice and enclosure temperature, so use the applicable load row.
- Auxiliary budget: Treat +5 VDC and +3.3 VDC as one shared 10 W allowance instead of budgeting each rail independently.
- System-power role: Use the regulated rails for the documented DeltaV controller and I/O-interface demand, not as an unspecified field-power source.
- Two-wide carrier: Mounts in either slot of a two-wide power/controller carrier.
- VerticalPlus carrier: Mounts in the power slot of a VerticalPlus four-wide carrier.
- Four-wide power carrier: May occupy any slot of that carrier.
- Status interfaces: Green DC Power, red Error and a normally open alarm relay support cabinet diagnostics.
- Fuse response: The internal fuse is non-replaceable, so correct the external cause before treating the supply as a complete replaceable module.
- Overvoltage boundary: The 110%–120% protection band is a protective response range, not a normal output-setting allowance.
- Ride-through limit: The 5 ms hold-up rating covers only a brief input interruption and must not be treated as backup power.
- Thermal recovery: Above +60°C the available output is derated; reduce the load or improve the enclosure condition before continuing.
- DeltaV controller power: Supplies the controller through a supported power/controller carrier.
- I/O-interface power: Provides +12 VDC for DeltaV I/O-interface demand.
- Redundant power layouts: Supports modular system-power arrangements described by Emerson for M-series carriers.
- Plant 24 VDC systems: Converts a common 24 VDC bulk source while maintaining isolation between system and field power.