Emerson VE5109 is a DeltaV M-series DC to DC system power supply accepting either 12 VDC or 24 VDC bulk power.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for VE5109
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for VE5109

  • Manufacturer:
    Emerson
  • Part Number:
    VE5109
  • Product Family:
    DeltaV
  • Product Type:
    M-series DC to DC System Power Supply
  • Stock:
    1
  • Bulk Power Input:
    12 VDC (-4%/+5%) at 14.8 A; 24 VDC ±20% at 6.1 A
  • Output at -40°C to +60°C:
    +12 VDC at 13 A with 12 V input or 8 A with 24 V input
  • Output at +60°C to +70°C:
    +12 VDC at 10 A with 12 V input or 6 A with 24 V input
  • Auxiliary Outputs:
    +5 VDC at 2 A; +3.3 VDC at 2 A; 10 W combined
  • Input Protection:
    Internally fused, non-replaceable
  • Overvoltage Protection:
    110% to 120%
  • Hold-up Time:
    5 ms at full load and minimum input voltage
  • Relative Humidity:
    5% to 95%, non-condensing
  • Airborne Contaminants:
    ISA-S71.04-1985 Class G3; conformal coating
  • Alarm Contact:
    Normally open relay, 2 A at 30 VDC or 2 A at 250 VAC
  • Estimated shipping dimensions:
    4.18 x 13.91 x 16.06 cm
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Source & Load Plan Mounting and Signals Fault Recovery Product Applications

Features:

  • Dual bulk-power inputs: Accepts either 12 VDC or 24 VDC plant power.
  • Multi-rail output: Supplies +12 VDC, +5 VDC and +3.3 VDC for DeltaV system electronics.
  • Integrated supervision: Provides status LEDs and a normally open alarm relay.
VE5109 is the ordered M-series DC to DC system power supply used to feed a DeltaV controller and I/O-interface power buses.

Its carrier connection keeps the power path modular while the specified input and output ranges let engineers calculate capacity for the actual bulk-power source.

Visible indicators and the alarm contact separate incoming-power and output-tolerance checks from broader controller diagnostics.

For Emerson VE5109 M-series DC to DC System Power Supply sourcing, Apter Power can help confirm carrier, load and quotation requirements.
Emerson VE5109 M-series DC to DC System Power Supply Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Bulk-source choice: Match VE5109 to either the documented 12 VDC or 24 VDC source and size upstream capacity for that selected input mode.
  • Main-rail capacity: Available +12 VDC current changes with bulk-input choice and enclosure temperature, so use the applicable load row.
  • Auxiliary budget: Treat +5 VDC and +3.3 VDC as one shared 10 W allowance instead of budgeting each rail independently.
  • System-power role: Use the regulated rails for the documented DeltaV controller and I/O-interface demand, not as an unspecified field-power source.
  • Two-wide carrier: Mounts in either slot of a two-wide power/controller carrier.
  • VerticalPlus carrier: Mounts in the power slot of a VerticalPlus four-wide carrier.
  • Four-wide power carrier: May occupy any slot of that carrier.
  • Status interfaces: Green DC Power, red Error and a normally open alarm relay support cabinet diagnostics.
  • Fuse response: The internal fuse is non-replaceable, so correct the external cause before treating the supply as a complete replaceable module.
  • Overvoltage boundary: The 110%–120% protection band is a protective response range, not a normal output-setting allowance.
  • Ride-through limit: The 5 ms hold-up rating covers only a brief input interruption and must not be treated as backup power.
  • Thermal recovery: Above +60°C the available output is derated; reduce the load or improve the enclosure condition before continuing.
  • DeltaV controller power: Supplies the controller through a supported power/controller carrier.
  • I/O-interface power: Provides +12 VDC for DeltaV I/O-interface demand.
  • Redundant power layouts: Supports modular system-power arrangements described by Emerson for M-series carriers.
  • Plant 24 VDC systems: Converts a common 24 VDC bulk source while maintaining isolation between system and field power.
Description
VE5109 converts plant 12 VDC or 24 VDC bulk power into the system voltages required by a DeltaV controller and its I/O interfaces. The carrier-mounted architecture avoids separate internal cabling and lets the same supply serve controller power and I/O-interface demand within the published output limits.

VE5109 combines modular mounting, input and output supervision, relay alarm signaling and visible power/error indication. These functions give panel designers a defined path for power distribution while giving maintenance teams clear entry points for diagnosing an incoming-supply or output-tolerance problem.

VE5109 also provides isolation between system power and field power when both use the same 24 VDC bulk source. Temperature derating, carrier position and load calculations remain part of the engineering decision because available +12 VDC output changes with input voltage and enclosure temperature.
Alternative Names
VE5109 VE 5109 Emerson VE5109 DeltaV VE5109 Emerson DeltaV DC to DC System Power Supply
Technical notes
VE5109 changes its +12 VDC capacity above 60°C: the rated output falls from 13 A to 10 A on a 12 V input and from 8 A to 6 A on a 24 V input. Size the load at the highest enclosure temperature, and stop selection if the derated current is insufficient.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How should a panel designer choose between 12 VDC and 24 VDC input for VE5109?
Match VE5109 to the available bulk-power source and calculate current at that input. The supply accepts 12 VDC at 14.8 A within -4%/+5%, or 24 VDC at 6.1 A within ±20%.
What does the red Error indicator mean during VE5109 troubleshooting?
The red indicator shows that the +5 VDC and +3.3 VDC outputs are out of tolerance. Start diagnosis at the supply output and load rather than treating the light as a controller-application fault.
How can the VE5109 alarm contact be integrated into cabinet monitoring?
Use the normally open relay as a discrete alarm path; it closes when the +3.3 VDC and +5 VDC outputs are within ±4% of nominal. Keep the contact within 2 A at 30 VDC or 2 A at 250 VAC.
Can a technician replace the internal input fuse in VE5109?
No. The input protection is internally fused and non-replaceable. When that protection has operated, troubleshoot the external source and load, then handle the supply as a complete replaceable module.
Which carrier positions can accept VE5109?
Use either slot of a two-wide power/controller carrier, the power slot of a VerticalPlus four-wide carrier, or any slot of a four-wide power carrier. Do not generalize this list to unlisted carriers.
What cabinet space should be reserved for VE5109?
The published hardware envelope is 4.18 x 13.91 x 16.06 cm. Reserve additional clearance required by the selected carrier, wiring and cabinet thermal design instead of treating the product dimensions as the complete installation envelope.