Technical specifications for PR6422-013-041

  • Manufacturer:
    Emerson
  • Part Number:
    PR6422-013-041
  • Product Family:
    Epro
  • Product Type:
    5 mm Armored Eddy Current Sensor
  • Stock:
    1
  • Case thread:
    M6×0.5
  • Cable armor:
    Yes
  • Sleeve length:
    50 mm
  • Total sensor length:
    55.3 mm
  • Total cable length:
    10 m
  • Nominal static range:
    ±0.5 mm
  • Recommended dynamic range:
    25 to 250 µm
  • Sensitivity:
    16 V/mm
  • Nominal center gap:
    Approximately 0.8 mm
  • Reference target:
    42CrMo4 / SAE 4140 steel
  • Minimum shaft diameter:
    ≥20 mm
  • Operating temperature:
    -35 to +180°C; up to +200°C short-term
  • Protection class:
    IP66
  • Cable minimum bend radius:
    35 mm with metal protection
  • Tariff Code:
    9031809090
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Mechanical Fit Measuring Chain Cable Practice Application
  • Confirm the calibrated sensor and converter belong to the same measuring chain
  • Protect the armored 10 m cable and adapter connection from strain and contamination
  • Set the working gap only after verifying the actual shaft material and geometry

Emerson PR6422-013-041 is a compact 5 mm eddy current probe for non-contact shaft displacement, position and vibration measurement.

The official PR6422/013-041 order code defines M6×0.5 mounting, cable armor, a 50 mm sleeve, adapter plug, 10 m total cable and an open cable end.

Before installation or replacement, verify the matching converter and serial-number pairing, target material, shaft diameter, initial gap, cable armor route, bend radius, terminal wiring and hazardous-area documentation.

Availability, condition, price, and shipping time for PR6422-013-041 are confirmed during quotation.

Emerson PR6422-013-041 Manuals, Datasheets, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • Use the M6×0.5 mounting thread and documented 50 mm sleeve reach
  • Provide a stiff holder and keep the probe axis within the published angular tolerance
  • Confirm shaft diameter and free metal clearance around the 5 mm head
  • Match the sensor type and serial number to the selected converter
  • Use the documented target material or a verified material-specific calibration
  • Keep the measurement inside the selected static or dynamic range
  • Respect the 35 mm minimum bend radius for the armored lead
  • Protect the adapter plug and open cable end from moisture and tensile load
  • Route the signal cable away from switching conductors and bond the shield as documented
  • Radial shaft vibration measurement on compact turbomachinery locations
  • Axial displacement, position or eccentricity monitoring with the matched converter
  • Speed or key-related measurement where the verified target and electronics support the application
Description
Emerson PR6422-013-041 is a compact 5 mm eddy current probe for non-contact shaft displacement, position and vibration measurement.

The official PR6422/013-041 order code defines M6×0.5 mounting, cable armor, a 50 mm sleeve, adapter plug, 10 m total cable and an open cable end.

Before installation or replacement, verify the matching converter and serial-number pairing, target material, shaft diameter, initial gap, cable armor route, bend radius, terminal wiring and hazardous-area documentation.
Alternative Names
PR6422-013-041 PR6422/013-041 PR 6422-013-041 PR 6422/013-041 Emerson PR6422-013-041 Emerson PR6422/013-041 Emerson Epro PR6422-013-041 Emerson Epro PR6422/013-041 Epro PR6422-013-041 Epro PR6422/013-041
Technical notes
PR6422-013-041 forms a calibrated measuring chain with an approved CON011, CON021, CON031, CON041 or supported integrated converter. Preserve the exact order code, target material and sensor-to-converter pairing.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Is Emerson PR6422-013-041 suitable when mounting space around the shaft is limited?
Its 5 mm probe head is intended for compact measuring locations, but the shaft must still exceed the documented minimum diameter and the bracket must remain stiff and vibration-free.
Can Emerson PR6422-013-041 be connected to any PR642x converter?
Do not assume interchangeability. Match the converter type and the sensor serial number shown on the calibrated measuring-chain label, or complete Emerson's approved calibration procedure.
What must be checked before reusing the existing 10 m cable route with Emerson PR6422-013-041?
Confirm the armor is undamaged, the adapter joint is protected, the 35 mm minimum armored-cable bend radius is respected, and the open-end conductors match the receiving circuit and shield plan.
Why can Emerson PR6422-013-041 show a different gap after an apparently correct replacement?
A changed target alloy, curved target, bracket position, probe angle, converter pairing or initial mechanical clearance can shift the electrical gap even when the thread fits.
Can two Emerson PR6422-013-041 probes be mounted close together?
Only after checking the official spacing and oscillator-frequency guidance. Nearby eddy current probes can interact and create unstable or biased readings.
What should be inspected if Emerson PR6422-013-041 output becomes noisy?
Inspect bracket rigidity, target surface, gap, cable and adapter condition, shielding, grounding, nearby high-current wiring, converter supply and possible probe-to-probe interference.
How should Emerson PR6422-013-041 be accepted after installation?
Perform a controlled gap check against the actual target, confirm signal direction and linear operation in the required range, compare the monitor value with a known reference and verify alarm behavior without exposing the machine to risk.