Features:
- Measures close-clearance shaft motion without contacting the target.
- Provides an 8 V/mm nominal scale factor across a 2 mm linear range.
- Uses the exact M10 x 1 unarmored body and 45 mm sleeve execution.
The compact probe monitors radial or axial shaft motion, position, eccentricity and speed on turbines, compressors, gearboxes, pumps and fans.
An electromagnetic field at the probe tip induces eddy currents in the ferromagnetic target. Gap-dependent loading changes the converter response, producing a calibrated voltage related to shaft-to-probe distance.
Match the CON041 converter and cable execution, target material and set gap before commissioning. Do not mix probes or converters from separately calibrated systems without completing the manufacturer calibration procedure.
Availability is reviewed against the exact PR6423/002-121 CON041 order identity and requested supply condition; manufacturer lifecycle status: Active / Available from OEM.
Verified resources for Emerson EPRO PR6423/002-121 CON041:
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- The /002 portion identifies the M10 x 1 unarmored PR6423/00 body with a 45 mm sleeve code. The legacy -121 cable and termination identity must be retained exactly from the supplied label and calibration record.
- The 8 mm probe and two-millimetre linear range support close-clearance measurements on shafts from 25 mm diameter in critical rotating equipment.
- Requires preservation of the complete -121 cable identity and matched CON041 calibration.
- Measures shaft vibration, position, eccentricity, and speed on rotating equipment.
- Uses an 8 mm eddy-current probe for compact machine applications.
- M10 x 1 case thread identifies the unarmored base execution.
- The -121 suffix identifies the legacy cable and termination execution.
- Sensor and first cable metre operate from -35 to 180 deg C.
- Converter output follows calibrated gap response for ferromagnetic targets.
- IP66 protection supports demanding installed industrial environments.
- Order-matrix case option 2 corresponds to a 45 mm sleeve.
- Linear measurement range is 2 mm, equivalent to 80 mil.