Features:
- Combines an 8 mm M10 x 1 probe with a matched CON021 signal converter.
- Provides a 2 mm linear range and 8 V/mm incremental scale factor.
- Uses armoured construction with a 5.0 m total cable and Lemo termination.
The ordered system includes the specified probe configuration, cable components and converter as one measurement chain. The 25 mm sleeve and armour define the mechanical installation.
Changes in shaft position alter the probe field, and the converter conditions this non-contact signal for vibration or displacement monitoring. The standard response extends from static measurement to 20 kHz.
Maintain the approved gap, target material, cable length and armour bend radius. Converter supply, output range and monitor scaling must be checked before the channel is placed in protection service.
Availability is confirmed after the complete suffix, converter range and installed monitor interface are reviewed.
Verified resources for Emerson EPRO PR6423/010-010 CON021:
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Measures radial shaft vibration on rotating machinery without mechanical contact.
- Provides static shaft position or gap information to machinery-monitoring channels.
- Supports condition and protection systems requiring a compact high-temperature proximity probe.
- The standard measuring range is 2 mm with an 8 V/mm incremental scale factor.
- Linearity deviation is specified at +/-0.025 mm from 0 to 45 deg C.
- The converter frequency response extends from 0 to 20 kHz at the -3 dB point.
- Converter output represents the changing distance between the probe tip and ferromagnetic shaft surface.
- Static gap and dynamic vibration components can be used by the connected machinery monitor.
- Channel scaling must correspond to the selected converter output range before alarms are enabled.
- The M10 x 1 body and 25 mm sleeve must be positioned to maintain the required measurement gap.
- Armoured cable requires a minimum 35 mm bend radius and strain relief near each connection.
- Probe, cable and converter identities should remain together as the calibrated measurement set.