Features:
- Provides a 65 mm forward sleeve with an M10 × 1 mounting thread.
- Uses a 5 m unarmoured cable with open-end termination.
- Pairs with a DIN-rail CON041 for 8 V/mm signal conditioning.
The 004 suffix defines a longer forward-sleeve geometry than the reverse 00R construction, even though both can use CON041 electronics.
Non-contact eddy-current sensing lets the channel observe fast shaft movement without a mechanical linkage or wear surface.
Measure the required insertion depth and cable-exit clearance before ordering. The final gap should be set only after the 65 mm body and its locknuts are stable.
PR6423/004-111 CON041 is matched by sleeve length, termination and converter execution.
Verified resources for Emerson PR6423/004-111 CON041:
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Reach a recessed shaft target through a longer threaded mounting bracket.
- Measure axial or radial movement with a forward-body 8 mm probe arrangement.
- Connect an open-ended field lead to existing DIN-rail conditioning electronics.
- Keep the exposed cable route clear of oil pooling, sharp edges and elevated surface temperatures.
- Mounting structure must resist vibration that is unrelated to the shaft measurement.
- The converter enclosure should remain dry, accessible and within its specified conditions.
- The 2 mm measurement span follows distance changes around the established operating point.
- A stable 8 V/mm response depends on the target and complete sensor-converter combination.
- Trend the baseline after installation so later mechanical movement can be distinguished from wiring drift.
- Retain the /004-111 suffix in inspection records and spare inventories.
- Apply the probe's IP66 rating only when the mechanical installation preserves its sealing conditions.
- Channel acceptance should follow the site's calibrated machinery-monitoring procedure.