Features:
- Interface between the fieldbus network and CPV10 valve terminal backplane
- Integrates capability of 16 digital inputs and 8 outputs with CP string extension support
- Functions in conjunction with CPV10 series valve terminals and Festo pneumatic components
The FESTO CPV10-GE-DN2-8 525630 operates as the Electrical interface in a CPV10 valve terminal system, managing communication between fieldbus protocols and all valve slices within the assembly. It continuously processes 16 input signals and controls 8 outputs (supporting up to 16 valves) while distributing power and data through the CP string to ensure coordinated operation of the entire pneumatic manifold. Seamless communication is standard with the FESTO CPV10-GE-DN2-8 525630, however utilizing the CP string extension capability will allow system expansion with additional valve terminal modules while maintaining diagnostic visibility across the complete string. The FESTO CPV10-GE-DN2-8 525630 has made improvements in several areas over previous electrical interface designs in addition to incorporating universal fieldbus connectivity with multiple interface options within the CPV platform.
The FESTO CPV10-GE-DN2-8 525630 provides essential communication and control functions common to the entire valve terminal, and is a critical component of the pneumatic control path, directly affecting the proper, normal operation of the overall automation system. One FESTO CPV10-GE-DN2-8 525630 Electrical interface is required per CPV string depending on the desired I/O configuration. The FESTO CPV10-GE-DN2-8 525630 occupies the dedicated electrical interface position in the valve terminal and is always located at the fieldbus connection point (the communication gateway for the CP string).
For expanded valve terminal applications, the CPV system requires utilization of the CP string extension capability built into the FESTO CPV10-GE-DN2-8 525630. In addition to standard single-section operation, the extension configuration also performs automatic module detection. The CPV string extension executes communication handshaking using the internal circuitry specified in the electrical interface options. Using this method, the extension system continually monitors the presence of all connected modules. If the system detects that a module is missing from the CP string (outside configured communication parameters), it will automatically report the fault condition and place a Missing module in CP string event in the diagnostic register.
The CPV10-GE-DN2-8 525630 FESTO Electrical interface may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
FESTO CPV10-GE-DN2-8 525630 Electrical interface Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
FESTO CPV10-GE-DN2-8 525630 Electrical interface Specs
General
- Manufacturer FESTO
- Model CPV10-GE-DN2-8 525630
- Condition New Original ready stock
- Product Family CPV10-GE-PT-8,CPV10-GE-CO3-8,CPV10-GE-IB-8
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Electronic & Semiconductor: Chip packaging and PCB assembly equipment.
- Packaging & Logistics: Labeling machines, filling systems, and conveyor technology.
- Automotive: Assembly lines for small components and pneumatic fixtures..
- Medical: Laboratory centrifuge door locks and assembly of medical devices.
- Specific Use Case: Ideal for high-speed machines that require short pneumatic tubing by mounting valves close to the cylinders.
- Mounting Orientation: The mounting position is optional (any orientation).
- Mounting Methods: It can be mounted on a wall or a DIN rail inside a control cabinet.
- Direct Integration: Using a pneumatic multiple connector plate allows installation directly in a housing wall, keeping tubing external to the cabinet.
- Fieldbus: Connects via a 5-pin screw terminal strip or M12x1 A-coded socket.
- CP String Extension: Supports an additional CP installation string for expanding I/O modules up to 10 metres away.
- Power Supply: Requires a nominal 24 V DC operating voltage, with separate connections often used for electronics and valve load supply to maintain safety and isolation.
- Protection Class: IP65 (dust-tight and protected against water jets) when fully assembled with the required seals.
- Operating Temperature Range: -5 °C to +50 °C.
- Storage Temperature Range: -20 °C to +70 °C.
- Humidity: Up to 93%, non-condensing.
- Corrosion Resistance: Rated CRC 1 (low corrosion stress), suitable for protected indoor environments.