  • Lifecycle status

    Active / Available from OEM
    Apter Power supports IS200ERBPG1A procurement while supplying accessible official documentation on request.

IS200ERBPG1A

/ 4.9
1001 reviews | Need a Specific Revision?
General Electric IS200ERBPG1A is an Exciter Regulator Backplane that provides the physical and electrical interconnect for EX2100 regulator boards.
In Stock
Ships by Saturday, November 14
Fast Shipping Available
Get a quick price for IS200ERBPG1A
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for IS200ERBPG1A

  • Manufacturer:
    General Electric
  • Part Number:
    IS200ERBPG1A
  • Product Family:
    GE Excitation Control
  • Product Type:
    Exciter Regulator Backplane
  • Stock:
    1
  • Control platform:
    GE EX2100 excitation control
  • Hardware role:
    Provides the physical and electrical interconnect for EX2100 regulator control boards
  • System placement:
    Seats the regulator cards in their assigned rack positions
  • Primary interface:
    Distributes control power through the regulator assembly
  • Signal or power function:
    Routes signals between installed control and interface boards
  • Associated hardware:
    Belongs to the EX2100 regulator hardware platform
  • Service consideration:
    Depends on cabinet cooling and grounding provisions
  • Verification point:
    Must be matched to the existing regulator chassis layout
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Card Slots Signal Paths Power & Ground Inspection

Features:

  • Seats the regulator cards in their assigned rack positions.
  • Distributes control power through the regulator assembly.
  • Routes signals between installed control and interface boards.
Within a simplex EX2100 regulator-control rack, IS200ERBPG1A provides the backplane position used by the ACLE module and its surrounding regulator hardware.

The keyed connectors on IS200ERBPG1A preserve assigned board locations while carrying signal and control-power paths across the regulator assembly.

Because IS200ERBPG1A is the common passive interconnect, a damaged mating contact can disturb more than one regulator-board function.

For regulator-backplane purchasing and available manufacturer literature, Apter Power supports the General Electric IS200ERBPG1A Exciter Regulator Backplane used in GE excitation-control service.
General Electric IS200ERBPG1A Exciter Regulator Backplane Manuals, Datasheets, LinksImportant Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Card-Slot Layout for IS200ERBPG1A

  • Source: Preserves fixed connector relationships within the rack.
  • Processing: Supports field cabling through backplane-mounted interfaces.
  • Destination: Keeps controller wiring organized as a replaceable assembly.
  • Verification: Belongs to the EX2100 regulator hardware platform.

Backplane Signal Paths for IS200ERBPG1A

  • Purpose: Keeps controller wiring organized as a replaceable assembly.
  • Connection: Belongs to the EX2100 regulator hardware platform.
  • Behavior: Uses keyed board positions to limit incorrect insertion.
  • Boundary: Requires inspection of mating connectors before reuse.

Power & Grounding for IS200ERBPG1A

  • Input path: Uses keyed board positions to limit incorrect insertion.
  • Output path: Requires inspection of mating connectors before reuse.
  • System effect: Depends on cabinet cooling and grounding provisions.
  • Check: Carries no standalone software configuration.

Replacement Inspection for IS200ERBPG1A

  • Placement: Depends on cabinet cooling and grounding provisions.
  • Interface: Carries no standalone software configuration.
  • Operation: Must be matched to the existing regulator chassis layout.
  • Service point: Seats the regulator cards in their assigned rack positions.
Description
Designed for GE EX2100 excitation control, the General Electric IS200ERBPG1A Exciter Regulator Backplane provides the physical and electrical interconnect for EX2100 regulator control boards. It seats the regulator cards in their assigned rack positions.

One operating responsibility of IS200ERBPG1A is that it routes signals between installed control and interface boards. It also supports field cabling through backplane-mounted interfaces.

System coordination matters because IS200ERBPG1A belongs to the EX2100 regulator hardware platform. It uses keyed board positions to limit incorrect insertion.

A controlled restart after installing IS200ERBPG1A should confirm the assigned path rather than only board power. The board carries no standalone software configuration. It must be matched to the existing regulator chassis layout.
Alternative Names
IS200ERBP G1A GE IS200ERBPG1A General Electric IS200ERBPG1A I5200ERBPG1A IS200 ERBPG1A IS200 ERBP G1A IS 200ERBPG1A IS-200-ERBPG-1A
Technical notes
IS200ERBPG1A is a passive interconnect assembly; bent contacts or an incorrect slot relationship can disrupt multiple regulator functions at once.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why might an ACLE fail to start after work on IS200ERBPG1A?
Check that the ACLE is squarely seated on IS200ERBPG1A and that rack power is present before investigating software.
How can IS200ERBPG1A be distinguished from a redundant regulator backplane?
IS200ERBPG1A serves the simplex regulator-control rack; redundant regulator racks use the ERRB backplane.
What should be recorded before moving boards or cables on IS200ERBPG1A?
Label each board position and front-panel cable before IS200ERBPG1A service so every connection returns to the correct slot.
Can IS200ERBPG1A be serviced while the simplex regulator remains energized?
No. De-energize and verify the IS200ERBPG1A rack before touching boards or connected circuits.
If ACLE communication disappears after IS200ERBPG1A service, what should be checked?
Recheck the ACLE backplane seating plus its Ethernet and serial cables; IS200ERBPG1A work can disturb either connection path.
Why should replacement boards be tightened evenly against IS200ERBPG1A?
Even tightening seats a module squarely into IS200ERBPG1A and reduces the risk of an incomplete backplane connection.
What proves the IS200ERBPG1A rack is ready for restart?
Confirm IS200ERBPG1A board seating, cable restoration, rack power indicators, and normal ACLE status before returning control.