GEC Industrial Controls 8177-4002 is a GEM 80 110 V AC input module with sixteen front-panel channel indicators numbered 0 through 15.
In Stock
Ships by Saturday, November 14
Fast Shipping Available
Get a quick price for 8177-4002
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 8177-4002

  • Manufacturer:
    GEC Industrial Controls
  • Part Number:
    8177-4002
  • Product Family:
    GEM80 Series
  • Product Type:
    GEM 80 110 V AC 16-Point Input Module
  • Stock:
    1
  • Input voltage marking:
    110 V AC
  • Input points:
    16
  • Channel indicator labels:
    0 through 15
  • Weight:
    0.58 kg
  • Estimated shipping dimensions:
    2.8 x 23.3 x 23.3 cm
  • Tariff Code:
    8537101190
  • Country of origin:
    United Kingdom
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Input Channels Module Construction Commissioning Checks Applications

Features:

  • 110 V AC input: The front panel is explicitly marked AC INPUT 110V.
  • Sixteen channels: Indicators numbered 0 through 15 provide visible channel status.
  • GEM 80 construction: Uses a full-size plug-in board with front faceplate and rack connector.
Safety decision: Isolate and prove dead all 110 V AC field circuits before module work.

Wiring decision: Document each channel and connector position before disconnection.

Startup decision: Test every documented input through both field wiring and control logic.

Apter Power supports GEC Industrial Controls 8177-4002 quotations, available technical documents and GEM 80 I/O guidance.
GEC Industrial Controls 8177-4002 GEM 80 110 V AC 16-Point Input Module Manuals,Datasheets,Link Important Notice: Manuals, software, cables, calibration data and accessories are included only when listed in the quotation.
  • Channel count: Sixteen front indicators are numbered 0 through 15.
  • Input marking: The faceplate states AC INPUT 110V.
  • Local status: Each numbered indicator provides a visible channel state.
  • Circuit mapping: Use the cabinet drawing to associate each number with its field signal.
  • Board format: Uses a full-size plug-in PCB for GEM 80 racks.
  • Front faceplate: Carries the input designation, channel indicators and module number.
  • Rack connector: A multipin edge interface connects the module to the installed rack.
  • Manufacturer marking: The faceplate states CEGELEC Industrial Controls, Kidsgrove England.
  • Field isolation: Prove every 110 V AC circuit dead before wiring work.
  • Channel wiring: Verify wire designations against the cabinet I/O drawing.
  • Indicator response: Check the corresponding front indication during controlled tests.
  • Logic response: Confirm each documented signal is processed correctly by the system.
  • Discrete AC inputs: Receives documented 110 V AC field states in GEM 80 systems.
  • Cabinet monitoring: Provides sixteen visible channel indications for installed I/O points.
  • Legacy I/O service: Supports maintenance of racks carrying the exact module type.
Description
The 8177-4002 is a CEGELEC Industrial Controls GEM 80 input module whose front panel is marked AC INPUT 110V. Sixteen visible indicators numbered 0 through 15 provide channel-level status on the installed rack.

The visible construction of 8177-4002 includes a full-size plug-in PCB, front faceplate and rack edge connector. The faceplate also carries CEGELEC INDUSTRIAL CONTROLS and KIDSGROVE ENGLAND markings, supporting the United Kingdom origin entry used on this page.

Before work on 8177-4002, isolate and prove dead every 110 V AC field circuit, document the channel wiring and indicators, and use ESD-controlled handling. Apter Power can provide quotations, available technical documents and GEM 80 I/O guidance.
Alternative Names
8177 4002 81774002 GEC 8177-4002 Cegelec 8177-4002 GEM 80 8177-4002 GEM80 8177 4002 8177-4002 AC Input Module GEC Industrial Controls 8177-4002
Technical notes
User-supplied product photographs confirm the exact 8177-4002 marking, CEGELEC Industrial Controls and Kidsgrove England labels, AC INPUT 110V designation, and sixteen indicators numbered 0 through 15. No manufacturer-authored exact-model manual was located, so input current, isolation, frequency, response time and connector pinout are intentionally omitted.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What should be checked when one channel indicator on 8177-4002 stays off?
Verify that the corresponding 110 V AC field signal is present under the approved test procedure, then check field wiring, terminals, rack seating and the control-system input state.
How should the field circuits be isolated before 8177-4002 is removed?
Apply the site lockout procedure, isolate every 110 V AC source, prove the circuits dead with approved equipment and document the channel wiring before touching the module.
What should be recorded before 8177-4002 is moved within a GEM 80 rack?
Record the rack slot, channel wire designations, connector orientation, indicator state, front-panel marking and the applicable I/O drawing.
What should be checked if all sixteen indicators on 8177-4002 remain dark?
Check rack power, module seating, shared field-supply conditions, connector engagement and the approved system diagnostics before removing another component.
How should wiring work on 8177-4002 be tested before restart?
Perform continuity and insulation checks required by the site procedure, verify channel assignments, restore power in a controlled sequence and test each documented input.
Why should both the field circuit and control logic be checked when troubleshooting 8177-4002?
The channel indication shows a local input state, while the cabinet logic and system diagnostics determine how that state is processed by the installed application.