IC697MDL653

/ 4.9
1001 reviews | Need a Specific Revision?
General Electric IC697MDL653 is a Series 90-70 discrete input module that accepts thirty-two 24 VDC field signals in positive- or negative-logic wiring arrangements.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for IC697MDL653
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for IC697MDL653

  • Manufacturer:
    General Electric
  • Part Number:
    IC697MDL653
  • Product Family:
    GE 90-70 Series PLC
  • Product Type:
    24 VDC Positive/Negative Logic 32-Point Input Module
  • Stock:
    1
  • Input voltage:
    24 VDC
  • Input logic:
    Positive or negative logic
  • Input points:
    32
  • RX7i hardware requirement:
    Version B or higher
  • RX7i slot classification:
    Double-width module
  • Backplane current at +5 VDC:
    0.3 A
  • Backplane current at +12 VDC:
    None listed
  • Backplane current at -12 VDC:
    None listed
  • Tariff Code:
    8538901100
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Logic-Level Match 32-Point Indication Field Signal Paths RX7i Setup

Features:

  • Thirty-two 24 VDC inputs support positive- or negative-logic field circuits.
  • RX7i installations require IC697MDL653 hardware Version B or higher.
  • The module draws 0.3 A from the rack's +5 VDC backplane supply.
IC697MDL653 brings a dense set of discrete field signals into a Series 90-70 control system while retaining flexibility over sourcing and sinking conventions.

Its RX7i compatibility boundary helps maintenance teams distinguish an acceptable spare from an earlier hardware build before a shutdown window begins.

Rack-power and wiring checks can be separated cleanly: the backplane demand is concentrated on +5 VDC, while field behavior depends on the selected 24 VDC logic reference.

The General Electric IC697MDL653 24 VDC Positive/Negative Logic 32-Point Input Module may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
General Electric IC697MDL653 24 VDC Positive/Negative Logic 32-Point Input Module Manuals, Datasheets, LinksImportant Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Supported Switching Devices

  • Contact inputs: IC697MDL653 accepts signals from pushbuttons, limit switches, and selector switches used in 24 VDC control circuits.
  • Proximity sensors: Both two-wire and three-wire electronic proximity switches are covered, with each device evaluated against the module's ON-state and OFF-state limits.
  • PLC outputs: A voltage-compatible IC697 output module can drive an input directly, allowing controller outputs to be returned as monitored logic states.
  • Leakage check: OFF-state compatibility requires the switch leakage to remain below 2 mA when the module input voltage is 5 V or less.

How Signal Changes Reach the Controller

  • Status display: Thirty-two LEDs at the top of IC697MDL653 show the ON or OFF state seen on the PLC side of each input circuit.
  • Input path: Each field signal passes through an opto-isolator and selectable filter before the system interface reports its state across the backplane.
  • Filter timing: The complete module can use a 1 ms or 10 ms input filter; the selected time applies to every point rather than to individual channels.
  • Interrupt response: Point A1 can interrupt an IC697 CPU on either a rising or falling transition, and its interrupt response is not changed by the filter-time selection.

Four Isolated Input Groups

  • Group layout: IC697MDL653 divides its thirty-two inputs into four isolated banks of eight, separating the A, B, C, and D field groups.
  • Individual feeds: Terminals 10, 20, 30, and 40 supply the respective banks because the four group power inputs are not connected inside the module.
  • Logic direction: Each input may sink or source current between the field device and its user common, supporting positive- or negative-logic circuits.
  • Two-wire behavior: Because a two-wire proximity switch powers itself through the signal pair, its voltage drop and leakage must both fall within the published compatibility region.

Software Settings and Slot Identity

  • Reference assignment: I/O references are configured in the programming software, so the module requires no addressing jumpers or DIP switches.
  • Programming access: The documented configuration path supports Ethernet TCP/IP or the SNP port from the applicable IC697 programming environment.
  • Module options: Configuration selects the common filter time and, with an IC697 CPU, enables point A1 as a rising-edge or falling-edge interrupt source.
  • Replacement control: A mechanical key remains on the backplane center rail after extraction and restricts the slot to an identical module type.
Description
General Electric IC697MDL653 is a Series 90-70 32-point input module for receiving 24 VDC discrete signals with either positive- or negative-logic field wiring. It provides a high-density interface between switches, contacts or sensors and the controller input table.

The logic convention is determined by the field reference arrangement rather than by a separate software personality. This allows the same module type to support sourcing or sinking practices, but the common connections and conductor polarity must agree with the selected circuit design.

In an RX7i installation, hardware Version B or later is required and the module occupies a double-width position. Its rack demand is concentrated on the +5 VDC rail, while point indicators provide a direct comparison between terminal activity and the input state seen by the controller.
Revisions

Revision Part #

Also known as

IC697MDL653H
IC697MDL653-H, Series H, Rev H
IC697MDL653G
IC697MDL653-G, Series G, Rev G
IC697MDL653F
IC697MDL653-F, Series F, Rev F
IC697MDL653E
IC697MDL653-E, Series E, Rev E
IC697MDL653D
IC697MDL653-D, Series D, Rev D
IC697MDL653C
IC697MDL653-C, Series C, Rev C
IC697MDL653B
IC697MDL653-B, Series B, Rev B
IC697MDL653A
IC697MDL653-A, Series A, Rev A
Alternative Names
General Electric IC697MDL653 GE Fanuc IC697MDL653 GE IC697MDL653 IC 697 MDL 653 IC697-MDL653 IC697MDL-653 IC697MDL6S3 IC697 MDL653
Technical notes
IC697MDL653 requires Version B or higher in an RX7i rack; its 0.3 A backplane demand is confined to the +5 VDC rail.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
For IC697MDL653, why can an input LED remain off when 24 VDC is present at the field device?
Check whether IC697MDL653 is wired for the intended positive- or negative-logic convention, then measure the voltage at the module terminal relative to the correct common. A reversed reference or open return path can leave the input inactive even when the field device itself is energized.
On IC697MDL653, what should be checked when several adjacent inputs fail together?
Trace the shared field supply and common before replacing IC697MDL653. Multiple channels failing as a group more often points to a missing common, blown protective device, disconnected terminal assembly, or loss of the associated 24 VDC distribution.
When working with IC697MDL653, can an early hardware version be installed in an RX7i rack?
The RX7i supported-module table requires IC697MDL653 Version B or higher. Record the suffix on the physical module and compare it with the rack documentation before moving an older spare into an RX7i installation.
During IC697MDL653 troubleshooting, how should intermittent input changes be investigated?
During IC697MDL653 troubleshooting, observe the channel indication while measuring the terminal voltage, then inspect loose conductors, contact bounce, cable shielding, and the stability of the 24 VDC source. Compare the field transition with the controller input table to distinguish wiring noise from a configuration issue.
Before servicing IC697MDL653, what rack-power allowance is required for this module?
IC697MDL653 is listed with a 0.3 A load on the +5 VDC backplane rail and no listed load on either 12 V rail. Include that 5 V demand in the total for every module installed in the rack.
With IC697MDL653 installed, what information should be recorded before replacing the module?
For an installed IC697MDL653, capture the complete catalog number and suffix, rack and slot, terminal assignments, logic convention, common arrangement, controller configuration, and the observed fault pattern. These details allow the replacement to be commissioned without guessing how the field circuits were referenced.
For a IC697MDL653 installation, how is the replacement checked before returning the process to service?
Before returning IC697MDL653 to service, with controlled power restored, confirm normal rack diagnostics and compare each required channel indication with its actual field state. Exercise representative sourcing and sinking circuits only under the approved site test procedure, then document the final input-table response.