Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Discontinued / Obsolete by OEM
    Apter Power supports IC660BBA106 quotation requests and applicable official GE Fanuc documentation for legacy current-source input sourcing requirements.

IC660BBA106

/ 4.9
1001 reviews | Need a Specific Revision?
General Electric IC660BBA106 is a 115 VAC/125 VDC Current-source Analog 6 Input Block for Genius distributed I/O and interfaces six isolated 4-20 mA transmitters using AC or DC block power.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for IC660BBA106
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for IC660BBA106

  • Manufacturer:
    General Electric
  • Part Number:
    IC660BBA106
  • Product Family:
    GE Genius I/O
  • Product Type:
    115 VAC/125 VDC Current-source Analog 6 Input Block
  • Stock:
    1
  • Input Circuits:
    6 analog inputs
  • Signal Range:
    4-20 mA
  • Input Accuracy:
    0.1% of full scale at 25°C
  • Input Resolution:
    1 µA
  • Conversion Time:
    16.6-400 ms selectable
  • Channel Isolation:
    1500 V RMS
  • Excitation:
    24 VDC per input
  • Diagnostics:
    High/low alarm, overrange, underrange, open wire
  • Control Power:
    93-132 VAC or 105-145 VDC
  • Weight:
    4 lbs (1.8 kg)
  • Estimated shipping dimensions:
    22.44 x 8.89 x 10.00 cm
  • Tariff Code:
    8538900000
  • Country of origin:
    United States
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Excitation Acquisition Diagnostics

Features:

  • Acquires six isolated 4-20 mA inputs with individual 24 VDC loop excitation.
  • Accepts either 115 VAC or 125 VDC block power without changing the analog channel functions.
  • Combines selectable conversion timing, engineering-unit scaling, alarms, and low-current detection.
Six isolated loop supplies can deliver transmitter excitation without sharing channel current paths.

A short-circuit current below 75 mA and the documented loop-impedance limits define the usable field circuit for each input.

IC660BBA106 communicates with later compatible Genius bus controllers and provides an output for the IC660BSM021 in redundant-bus service.

Legacy sourcing remains possible through Apter Power for the General Electric IC660BBA106 115 VAC/125 VDC Current-source Analog 6 Input Block following OEM EOL.
General Electric IC660BBA106 115 VAC/125 VDC Current-source Analog 6 Input Block Manuals, Datasheets, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

General Electric IC660BBA106 115 VAC/125 VDC Current-source Analog 6 Input Block Specs

General

  • ManufacturerGeneral Electric
  • ModelIC660BBA106
  • ConditionNew Original ready stock
  • Product FamilyGE Genius I/O

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Transmitter Loop Supply

  • Loop Power: Each input provides 24 VDC excitation.
  • Isolation: Every channel is isolated from the other circuits.
  • Impedance: Input impedance is 100 ohms ±5%.
  • Capacity: Loop impedance can reach 1000 ohms below 20 mA.

Current Measurement Control

  • Resolution: Measures in 1 µA increments.
  • Accuracy: Rated at 0.1% of full scale at 25°C.
  • Conversion: Selectable input time ranges from 16.6 to 400 ms.
  • Scaling: Converts raw current to configured engineering units.

Process Loop Status

  • Low Signal: Detects current below 2 mA.
  • High/Low Alarm: Supports separate process alarm limits.
  • Overrange: Reports current beyond the configured range.
  • Underrange: Identifies current below the configured range.
  • Per-channel Reporting: Fault reporting is selectable for each input.
Description
The controller receives IC660BBA106 measurements with 1 µA resolution and 0.1% full-scale accuracy at 25°C after the configured linear scaling is applied.

A selectable 16.6-400 ms conversion period lets IC660BBA106 trade faster acquisition for additional filtering according to the behavior of the connected transmitters.

Input 1 on IC660BBA106 shares a common with the Bus Switching Module output, whereas the remaining five current channels stay isolated from that auxiliary circuit.

The IC660BBA106 supports CPU redundancy and per-channel fault reporting when used with the later Genius controllers and software levels specified for this block family.
Alternative Names
General Electric IC660BBA106 GE Fanuc IC660BBA106 GE IC660BBA106 IC-660-BBA-106 IC660 BBA 106 IC660BBA106 Genius I/O Block IC660BBA106 Datasheet IC660BBA106 Technical Manual
Technical notes
IC660BBA106 requires IC660HHM501H version 4.5 or later; older IC660CBB900 and IC660CBB901 bus controllers are not supported.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which control power can IC660BBA106 use?
IC660BBA106 operates from either 93-132 VAC or 105-145 VDC while maintaining the same six current-input functions.
What transmitter loop power is available from IC660BBA106?
Every IC660BBA106 input provides 24 VDC excitation with the documented loop-current and impedance limits.
Why does IC660BBA106 Input 1 share a common?
Input 1 on IC660BBA106 shares a common with the Bus Switching Module output used in supported redundant-bus arrangements.
What controller restriction applies to IC660BBA106?
IC660BBA106 does not support IC660CBB900 or IC660CBB901 bus controllers and requires the later controller and software levels listed for the block.
How can IC660BBA106 detect an abnormal low loop current?
IC660BBA106 identifies input current below 2 mA separately from configured underrange and high or low process alarms.
Which details should be included in an IC660BBA106 quotation request?
Provide the full IC660BBA106 model, quantity, destination, AC or DC supply choice, and any installed station or nameplate information.
Where can the official IC660BBA106 block data be read?
The IC660BBA106 Manuals tab links to the General Electric user-manual excerpt covering the six-input current-source blocks.

Product Browsing History