Features:
- Accepts sixteen 115 VAC input points for a Series Three controller.
- Maintains one continuous reference block for the discrete AC states handled by the module.
- Requires 170 mA from the +5 V rail with no assigned +12 V load.
IC630MDL325 transfers sixteen alternating-current field states into one Series Three rack position.
Each field circuit must stay aligned with its assigned controller reference so a missing input can be isolated without disturbing the other fifteen points.
IC630MDL325A adds seventeen +5 V load units, and the receiving slot must preserve both the sixteen-point address block and 115 VAC wiring arrangement.
The General Electric IC630MDL325 AC Input Module may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
General Electric IC630MDL325 115 VAC Input Module Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
How the module fits the Series Three input path
- Signal class: IC630MDL325 is identified for 115 VAC discrete input service.
- Point capacity: Sixteen field states are presented through one module position.
- Controller result: Each physical condition is represented by its assigned discrete reference.
- Identity check: IC630MDL325A is the complete manufacturer-listed catalog number.
Preserving the sixteen-point assignment
- Reference group: Keep all sixteen IC630MDL325 points in one documented controller block.
- Slot relationship: Match the block to the actual Series Three rack position of IC630MDL325.
- Field record: Identify the 115 VAC circuit represented by each reference.
- Program check: Compare the expected and observed state before altering control logic.
Separating field, mapping, and rack issues
- Single missing point: Trace its 115 VAC field condition and assigned IC630MDL325 reference together.
- Wrong address: Reconcile the sixteen-point program block with the physical slot.
- Module-wide loss: Check seating and shared rack conditions before treating every field circuit as failed.
- Recorded baseline: Retain the known circuit-to-reference map for comparison after service work.
Series Three power-budget facts
- +5 V load: IC630MDL325A is assigned seventeen load units.
- Calculated current: At 10 mA per unit, the +5 V demand is 170 mA.
- +12 V rail: The manufacturer table lists no +12 V demand.
- Calculation basis: The published value uses the worst-case condition with all inputs and outputs on.