    For IC655PWR501 quotation and availability enquiries, Apter Power can help locate a matching 12 amp rack supply.

IC655PWR501

/ 4.9
1001 reviews | Need a Specific Revision?
General Electric IC655PWR501 is a 115/230 VAC Input, 12 Amp Power Supply Module that provides high-capacity +5 VDC backplane power for a Series Five CPU or I/O expansion base.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for IC655PWR501
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for IC655PWR501

  • Manufacturer:
    General Electric
  • Part Number:
    IC655PWR501
  • Product Family:
    GE Intelligent Platforms
  • Product Type:
    115/230 VAC Input, 12 Amp Power Supply Module
  • Stock:
    1
  • Product family:
    Series Five PLC
  • AC input:
    115 or 230 VAC, ±15%
  • Input frequency:
    48 to 63 Hz
  • Maximum load:
    170 VA
  • Backplane output:
    5.1 VDC, ±0.204 VDC
  • Output current:
    0.1 to 12 A
  • Inrush current:
    13 A typical at 4 ms; 50 A maximum at 8 ms
  • Fuse:
    3.15 A, 250 V, normal blow
  • RUN relay:
    250 VAC, 5 A resistive load
  • Weight:
    2.65 lbs (1.2 kg)
  • Estimated shipping dimensions:
    3.8 × 25.4 × 12.7 cm
  • Tariff Code:
    8504409999
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals 12 A Rack Demand Heat Load Alarm Reading Branch Safeguards

Features:

  • A twelve-amp regulated output supports Series Five racks with heavier internal module demand.
  • The AC input range is selected by a visible terminal jumper rather than an internal adjustment.
  • Separate PWR and RUN indications distinguish supply availability from processor operating state.
IC655PWR501 is primarily a rack-capacity decision: its twelve-amp output provides margin for module combinations that exceed the smaller AC supply, but unused current capacity does not change individual module requirements.

Upstream protection must account for the supply's input burden and startup surge as well as the steady backplane total, especially where several control racks share one cabinet branch.

Separate power and run indications help distinguish an energized supply from a processor that is actually executing, preventing a healthy input feed from being mistaken for a healthy control state.

General Electric IC655PWR501 115/230 VAC Input, 12 Amp Power Supply Module may be available for purchase and support from Apter Power.
General Electric IC655PWR501 115/230 VAC Input, 12 Amp Power Supply Module Manuals, Datasheets, Links Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Positioning the twelve-amp supply in a Series Five base

  • Dedicated location: IC655PWR501 mounts at the far left, where its rear connector feeds the base-unit power conductors.
  • CPU base: Processor and local I/O demand are totaled against this supply when the base is configured as the controller rack.
  • Expansion base: A separate IC655PWR501 may serve an added I/O base whose installed modules require the higher current capacity.
  • Growth decision: If the calculated demand exceeds the available twelve amps, the design must distribute modules among additional powered bases rather than overload one rack.

Maintaining airflow around a higher-load rack supply

  • Intake limit: Air entering the modules must remain at or below 60 °C throughout operation.
  • Natural cooling: The base dissipates heat by convection, so blocked openings can undermine cooling even though no fan is required.
  • Vertical clearance: Leaving 50 mm above and below the base gives warm air a path away from the supply and adjacent modules.
  • Rack spacing: Multiple horizontal bases need separation and clear sides so heat removal does not conflict with module access.

Separating power health from controller operation

  • PWR on: A lit green indicator confirms that incoming AC is present and the regulated +5 VDC output has reached its usable level.
  • PWR off: An extinguished lamp can reflect loss of the branch source or a low internal output, so both sides of the conversion path require attention.
  • RUN transition: The relay contacts change only with processor RUN state, providing a status channel independent of the front power lamp.
  • External visibility: Connecting a rated annunciator to those isolated contacts lets operators recognize a stopped CPU from outside the enclosure.

Protecting the high-capacity AC input path

  • Branch design: Upstream protection must carry the normal input load while riding through the brief starting current specified for IC655PWR501.
  • Internal fuse: The approved 3.15 A, 250 V normal-blow device protects this twelve-amp version and must not be confused with the smaller supply's rating.
  • Voltage choice: Energization is safe only after the bottom-terminal jumper arrangement agrees with the actual 115 or 230 VAC source.
  • Terminal access: De-energize the branch before removing the cover because hazardous voltage can remain on the hot, neutral, and selection connections.
Description
General Electric IC655PWR501 is a 12 A Series Five power-supply module for CPU and I/O expansion bases supplied from 115 or 230 VAC. It provides the higher-capacity AC option for racks whose calculated +5 VDC demand exceeds the capability of the six-amp supply.

Input-voltage selection is made at the field terminals, while the upstream branch must accommodate both normal input burden and the short startup surge. The additional output capacity supports denser rack populations but does not remove individual module or environmental limits.

Separate PWR and RUN indications distinguish regulated backplane power from processor operating state. This separation is useful when a rack is energized but the controller is stopped, because the two conditions require different checks and should not be represented by one combined status signal.
Alternative Names
IC 655 PWR 501 IC-655-PWR-501 GE IC655PWR501 GE Fanuc IC655PWR501 Series Five IC655PWR501 IC655PWR5O1 1C655PWR501 IC655 PWR501
Technical notes
IC655PWR501 can impose a 50 A maximum startup surge; upstream protection must tolerate this transient while preserving the approved branch-circuit rating.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
When is IC655PWR501 preferable to the lower-capacity AC supply?
Choose IC655PWR501 when the combined maximum backplane demand of the Series Five processor and installed modules is above six amps but does not exceed twelve amps.
The branch breaker trips while IC655PWR501 starts. What should be reviewed?
IC655PWR501 can draw a brief 50 A maximum inrush. Review the upstream protective device, conductor rating, and available source without increasing protection beyond the approved circuit design.
Does IC655PWR501 use the same jumper position for both AC ranges?
No. IC655PWR501 requires the bottom-terminal jumper for a 115 VAC source; the jumper is left off for a 230 VAC source.
How can a technician tell whether IC655PWR501 is delivering usable backplane power?
The green PWR lamp on IC655PWR501 remains on while the input is present and the regulated +5 VDC output is at its operating level.
Can the RUN contacts on IC655PWR501 switch an alarm circuit?
Yes. IC655PWR501 provides normally open RUN contacts rated for a resistive load up to 250 VAC and 5 A, allowing a suitably designed external indicator circuit.
What ground arrangement is required when several bases use IC655PWR501?
With IC655PWR501 installed across multiple bases, bond C to G only at the first CPU base and interconnect corresponding grounds between the remaining bases.
Why should the terminal cover be refitted on IC655PWR501 after service?
Refitting the cover on IC655PWR501 shields the line-voltage terminal block from accidental contact during normal access to the Series Five rack.