    Apter Power can quote and source IC630PWR324 as a high-capacity 24 VDC power supply for a Series Three remote I/O base.

IC630PWR324

/ 4.9
1001 reviews | Need a Specific Revision?
General Electric IC630PWR324 is the high-capacity 24 VDC power supply assigned to a Series Three remote I/O base.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for IC630PWR324
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for IC630PWR324

  • Manufacturer:
    General Electric
  • Part Number:
    IC630PWR324
  • Product Family:
    GE Intelligent Platforms
  • Product Type:
    High-Capacity 24 VDC Remote I/O Power Supply
  • Stock:
    1
  • Power-source assignment:
    Remote I/O base
  • Controller family:
    GE Series Three
  • Applicable base sizes:
    4, 6, or 8 module positions
  • Input source:
    24 VDC
  • Capacity class:
    High-capacity
  • +5 V load allocation:
    300 load units
  • +12 V load allocation:
    200 load units
  • Load-unit basis:
    10 mA per load unit
  • Power-supply position:
    Dedicated base supply position
  • Base requirement:
    One power supply for the configured base
  • Source wiring:
    Correct positive and negative DC connections
  • Status indication:
    RUN and FAULT operating states
  • Relay monitoring:
    Separate RUN and FAULT contacts
  • Commissioning load:
    Evaluate with remote interface and I/O installed
  • Load calculation scope:
    Remote I/O interface and installed I/O modules
  • Tariff Code:
    8504409999
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Remote DC Station Power Polarity Load Check

Features:

  • Feeds a Series Three remote I/O base from a 24 VDC source.
  • Places power at the remote station instead of extending the CPU-base supply across the system.
  • Provides separate backplane capacity for the two internal voltage rails.
IC630PWR324 combines the remote-base assignment with direct-current input; the corresponding 24 VDC supply for the processor base is IC630PWR314.

The positive and return conductors establish the DC input condition, making polarity the key line-side connection check.

Each remote station is evaluated from the I/O modules installed in that base, with rail demand kept independent.

The General Electric IC630PWR324 24 VDC remote I/O base power supply remains in the active OEM lifecycle category, and Apter Power can assist with quotation requests.
General Electric IC630PWR324 High-Capacity Remote I/O Base Power Supply Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Defining the remote DC supply role

  • Station type: IC630PWR324 is assigned to a Series Three remote I/O base.
  • Source type: The supply receives 24 VDC at the remote cabinet.
  • CPU distinction: IC630PWR314 is the DC counterpart for the local processor base.
  • Base ownership: The remote station uses the supply fitted to its own base rather than drawing backplane power from another rack.

Keeping power local to the I/O station

  • Separate base: Each remote I/O base forms its own powered station in the expanded system.
  • Dedicated position: IC630PWR324 occupies the supply location beside the remote base module positions.
  • Installed modules: The station load follows the I/O and interface hardware actually present in that base.
  • Expansion effect: Adding a base changes the system power arrangement because the added station also requires a suitable supply.

Establishing the 24 VDC connection

  • Positive lead: The positive conductor must enter the designated DC input terminal.
  • Return lead: The return path completes the intended 24 VDC source connection.
  • No AC selection: IC630PWR324 does not use the 115/230 VAC terminal choice of the remote AC model.
  • Backplane feed: Correct DC input allows the supply to energize the remote Series Three backplane.

Checking the remote base before service

  • Rail separation: Calculate +5 V and +12 V demand as two independent totals.
  • Module entries: Use the published load contribution for every module installed at the station.
  • Unused capacity: Spare capability on one rail does not compensate for an excess on the other.
  • Final comparison: Compare both completed totals with the IC630PWR324 capacity rather than judging by free module positions.
Description
Using a direct-current feeder at a remote Series Three station, the General Electric IC630PWR324 supplies the I/O base from 24 VDC.

The unit is cataloged for the remote-base position rather than the rack that contains the processor. This makes the power boundary follow the physical station boundary in a multi-base Series Three arrangement.

Positive and return connections determine the condition presented to the DC input. Unlike the remote AC model, there is no 115/230 V terminal selection; correct polarity is the defining line-side check.

The remote module set draws from separate +5 V and +12 V backplane allowances. Evaluating the actual I/O population keeps the station power decision tied to its electrical demand instead of only to the number of available positions.
Revisions

Revision Part #

Also known as

IC630PWR324A
IC630PWR324-A, Series A, Rev A
Alternative Names
IC630 PWR324 IC630-PWR324 IC-630-PWR-324 GE IC630PWR324 General Electric IC630PWR324 Series Three PWR324 IC630PWR3Z4 IC63OPWR324
Technical notes
IC630PWR324 requires correct 24 VDC polarity before it can energize the remote I/O backplane.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why is IC630PWR324 assigned to a remote I/O base instead of the local CPU base?
IC630PWR324 supplies a Series Three remote I/O base from 24 VDC, while IC630PWR314 serves the corresponding local CPU base.
Which loads must be included when checking IC630PWR324 capacity?
The IC630PWR324 assessment includes the remote I/O interface and all installed I/O modules on their respective +5 V and +12 V rails.
Why must both rail totals be calculated separately for IC630PWR324?
IC630PWR324 provides independent 300-unit +5 V and 200-unit +12 V allowances, so unused capacity on one rail does not increase the other.
What wiring check is required before IC630PWR324 is energized?
IC630PWR324 uses a polarity-sensitive 24 VDC input, requiring the positive and negative conductors to match the marked terminals.
What current is represented by the load-unit ratings of IC630PWR324?
For IC630PWR324, one load unit equals 10 mA, making the published rail allowances equivalent to 3.0 A at +5 V and 2.0 A at +12 V.
Where is IC630PWR324 installed within a Series Three base?
IC630PWR324 occupies the dedicated left-side power-supply position of the configured remote I/O base.
Does an expansion cable let IC630PWR324 power the next base?
No. An IC630PWR324 installation requires a compatible supply for each Series Three base, even when the bases share expansion connections.