General Electric DS200DTBBG1A is a Mark V LM contact input expansion termination module that connects the last 46 field contact inputs in a digital core to the associated TCDA board.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for DS200DTBBG1A
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for DS200DTBBG1A

  • Manufacturer:
    General Electric
  • Part Number:
    DS200DTBBG1A
  • Product Family:
    GE Mark V/VI Driver Board
  • Product Type:
    Contact Input Expansion Termination Module
  • Stock:
    1
  • Control Platform:
    Mark V LM SPEEDTRONIC
  • Core Locations:
    , , and
  • Input Bank:
    Last 46 contact inputs
  • Controller Interface:
    JRR to TCDA
  • Contact Power Source:
    JY from DTBA
  • Test Isolation:
    BJ1 through BJ5
  • Normally Unused:
    JRS and JRT
  • Tariff Code:
    8538900000
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Input Expansion DTBA Link Test Groups Validation

Features:

  • Adds the last 46 contact inputs to the TCDA board in a Mark V LM digital core.
  • Receives contact power through JY from the companion DTBA module.
  • Uses JRR as the common expansion-bank signal connection to TCDA.
DS200DTBBG1A is the contact input expansion termination module for the Q11, Q21, and Q51 digital cores. It complements DTBA rather than duplicating the first input bank.

BJ1 through BJ5 isolate input groups from the 125 V DC source for testing. JRS and JRT are normally unused.

Contact-sense inversion is set in the TCDA I/O Configuration, allowing the logic state to follow the required failsafe convention.

Continued purchasing and documentation support for the General Electric DS200DTBBG1A Contact Input Expansion Termination Module remains available from Apter Power after manufacturer End-of-Life (EOL).
General Electric DS200DTBBG1A Contact Input Expansion Termination Module Manuals, Datasheets, Links Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Last 46 contact inputs

  • Expansion-bank assignment: DS200DTBBG1A carries the final 46 contact inputs associated with the TCDA board in the same digital core. These points follow the DTBA first bank in the controller input map.
  • JRR boundary: JRR is the shared signal connection for the expansion bank. A full-bank loss should therefore be separated from a single terminal failure by checking JRR first.
  • Channel alignment: Channel numbers, field conductors, and TCDA assignments must remain aligned when the expansion bank is reconnected.

JY contact-power source

  • Upstream supply: Unlike DTBA, DS200DTBBG1A does not receive its 125 V DC contact power directly from TCPD. Its JY connector receives that supply from the companion DTBA board.
  • Fault boundary: This arrangement creates a useful fault boundary: healthy DTBA points with a dead DTBB bank direct attention to the JY path and the DTBB side of the circuit.
  • JRS/JRT boundary: JRS and JRT are normally unused and do not replace the JY operating supply connection.

BJ jumper behavior

  • Expansion-bank isolation: BJ1 through BJ5 isolate groups of DTBB contact inputs from the 125 V DC source for testing. An open BJ group affects multiple points even when the field contacts and JRR cable are intact.
  • Return position: Record the initial jumper map before a test and restore every group to its recorded position afterward.
  • Residual point fault: If one point remains abnormal after the group supply is restored, test that field contact and conductor independently from the shared JRR path.

Separating wiring from configuration

  • Fault layers: A missing physical state can originate at the field contact, the landed terminal, JY power, JRR connectivity, or the TCDA assignment. The pattern of affected points narrows the search.
  • Logical reversal: An input that changes but appears logically reversed calls for review of the TCDA sense-inversion setting, not an immediate change to terminal polarity.
  • Acceptance check: Validation is complete when every disturbed field contact produces the intended state at its mapped TCDA channel.
Description
General Electric DS200DTBBG1A is the DTBB Contact Input Expansion Termination Module installed in the Mark V LM Q11, Q21, and Q51 digital cores. It adds the final 46 contact inputs for the TCDA board in the same core.

The expansion-bank signals leave DS200DTBBG1A through JRR. Its JY connector receives the 125 V DC contact-power source from the companion DTBA module, so the DTBA-to-DTBB link is part of the complete input path.

Five BJ jumpers on DS200DTBBG1A isolate defined contact-input groups from the 125 V DC source during testing. JRS and JRT are normally unused in this arrangement.

The TCDA I/O Configuration can invert the sense of individual DS200DTBBG1A inputs for the required failsafe behavior. This board provides the physical expansion termination layer while channel meaning remains tied to the installed wiring map and TCDA assignment.
Alternative Names
DS200-DTBB-G1A DS200 DTBB G1A GE DS200DTBBG1A GE Mark V DS200DTBBG1A DS200DTBB G1A DS2O0DTBBG1A DS200DTBBGIA DS200DTBBG1A-GE
Technical notes
DS200DTBBG1A terminates the last 46 contact inputs; JRR connects the bank to TCDA and JY receives its 125 V DC contact-power feed from DTBA.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why can all DTBB inputs be lost while DTBA inputs remain present?
DS200DTBBG1A receives its 125 V DC contact power through JY from DTBA. Verify that inter-board supply link before checking each expansion input separately.
What should be checked when the entire expansion bank is missing at TCDA?
Inspect JRR seating, orientation, and continuity. JRR is the common DS200DTBBG1A signal path to TCDA, so one connector problem can affect many channels.
Why does one field contact show the opposite state?
The TCDA channel may be configured with input-sense inversion for failsafe operation. Compare the I/O Configuration with the intended contact convention before moving conductors.
How should BJ1 through BJ5 be handled during testing?
Use only the group required by the documented test and record the original positions. Leaving a BJ group isolated removes its contact-power path and can resemble an input failure.
What does a single unstable DTBB input suggest?
Focus on the field contact, terminal pressure, conductor, and assigned channel. Shared JY or JRR faults usually affect a broader pattern than one point.
Why can several adjacent inputs fail after a cable was disturbed?
Adjacent losses can follow a common JRR cable group or connector seating problem. Compare the affected point pattern with the terminal map before replacing DS200DTBBG1A.
How can the last 46 inputs be validated after reconnection?
Exercise representative field contacts across the expansion bank, then confirm their assigned TCDA states and any configured inversion; test every disturbed point.