    Apter Power can provide DS200TCEBG1ACE for mark v protective termination board replacement and installed-system maintenance; confirm the complete configuration and delivery requirements before ordering.

DS200TCEBG1ACE

/ 4.9
1001 reviews | Need a Specific Revision?
DS200TCEBG1ACE is a GE Vernova Mark V Protective Termination Board for mark v protective termination board replacement and installed-system maintenance.
In Stock
Ships by Saturday, October 31
Fast Shipping Available
Get a quick price for DS200TCEBG1ACE
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for DS200TCEBG1ACE

  • Manufacturer:
    General Electric
  • Part Number:
    DS200TCEBG1ACE
  • Product Family:
    GE Mark V/VI Driver Board
  • Product Type:
    Mark V Protective Termination Board
  • Stock:
    1
  • Hardware function:
    Mark V Protective Termination Board
  • Control platform:
    Legacy GE drive and turbine control
  • Interface scope:
    Board- or module-specific interfaces for the Legacy GE drive and turbine control installation
  • Primary application:
    Mark V Protective Termination Board replacement and installed-system maintenance
  • Hardware identity:
    DS200TCEBG1ACE
  • Replacement basis:
    Exact hardware and installed configuration match
  • Commissioning checks:
    Power, grounding, wiring, diagnostics and channel response
  • Documentation basis:
    OEM-authored family reference plus installed nameplate
  • Weight:
    0.65 kg
  • Estimated shipping dimensions:
    27.8x21.2x2cm
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Hardware Data Compatibility Commissioning Installation Check

Product overview:

  • Mark V Protective Termination Board
  • Legacy GE drive and turbine control
  • Mark V Protective Termination Board replacement and installed-system maintenance

DS200TCEBG1ACE provides board- or module-specific interfaces for the legacy ge drive and turbine control installation.

Confirm the exact nameplate, hardware revision, firmware, rack or cabinet position, terminal assignments and connected equipment.

Apter Power can provide DS200TCEBG1ACE for quotation and technical review.

Hardware data:

  • Exact identity: DS200TCEBG1ACE
  • Function: Mark V Protective Termination Board
  • Platform: Legacy GE drive and turbine control

Board- or module-specific interfaces for the Legacy GE drive and turbine control installation

Compatibility review:

  • Confirm the exact nameplate, hardware revision, firmware, rack or cabinet position, terminal assignments and connected equipment.
  • Compare connectors, terminal assignments and configured options
  • Use an engineered migration when revisions are not interchangeable

DS200TCEBG1ACE should be matched to the complete installed control assembly.

Commissioning checks:

  • Verify power and protective isolation
  • Confirm grounding, shielding and field wiring
  • Test diagnostics and functional response

Record baseline results for DS200TCEBG1ACE before returning the machine to service.

Installation check:

  • Photograph the original hardware and settings
  • Follow site lockout/tagout and ESD controls
  • Inspect connectors, torque and ventilation

Do not energize DS200TCEBG1ACE until wiring and configuration reviews are complete.

Description

DS200TCEBG1ACE is a GE Vernova Mark V Protective Termination Board associated with the Legacy GE drive and turbine control platform. Its documented role is mark v protective termination board replacement and installed-system maintenance, with board- or module-specific interfaces for the legacy ge drive and turbine control installation.

DS200TCEBG1ACE must be treated as one complete hardware and configuration reference. The board or module, terminal arrangement, firmware and connected control hardware must match the installed cabinet drawings; a similar family code does not establish electrical or functional interchangeability.

Before installing DS200TCEBG1ACE, isolate power, photograph the existing nameplate and connectors, record rack position and jumper settings, compare terminal assignments, and verify power, grounding, field wiring and diagnostics during commissioning.

Revisions

Revision Part #

Also known as

DS200TCEBG1AAA
DS200TCEBG1A-AA, Series -AA, Rev -AA
DS200TCEBG1AAB
DS200TCEBG1A-AB, Series -AB, Rev -AB
DS200TCEBG1ABC
DS200TCEBG1A-BC, Series -BC, Rev -BC
DS200TCEBG1ACD
DS200TCEBG1A-CD, Series -CD, Rev -CD
Alternative Names
DS200TCEBG1ACE GE Vernova DS200TCEBG1ACE DS200TCEBG1ACE Mark V Protective Termination Board DS200TCEBG1ACE replacement module DS200TCEBG1ACE spare part DS200TCEBG1ACE datasheet DS200TCEBG1ACE industrial control component 7 DS200TCEBG1ACE industrial control component 8
Technical notes
DS200TCEBG1ACE is the exact mark v protective termination board reference for the Legacy GE drive and turbine control installation. Confirm the exact nameplate, hardware revision, firmware, rack or cabinet position, terminal assignments and connected equipment.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which installed details must match before replacing DS200TCEBG1ACE?
Match the complete DS200TCEBG1ACE nameplate, hardware revision, firmware, rack or cabinet position, connectors and terminal assignments.
How should the interface for DS200TCEBG1ACE be verified?
Use the system drawings to verify board- or module-specific interfaces for the legacy ge drive and turbine control installation, including signal type, polarity, reference potential and grounding.
What should be checked before applying power to DS200TCEBG1ACE?
Confirm supply voltage, protective devices, connector keying, jumper positions, field isolation and cabinet grounding before energizing.
How is DS200TCEBG1ACE commissioned after installation?
Check the mark v protective termination board replacement and installed-system maintenance function channel by channel and compare diagnostics, feedback and commanded states with the original configuration.
Can a similar family board replace DS200TCEBG1ACE?
Not by part-family similarity alone. Electrical interfaces, firmware, revision, options and configured function must be reviewed as one replacement package.
What manual should be used for DS200TCEBG1ACE?
Use the product-specific Apter Power datasheet together with the latest applicable OEM system manual and the installed cabinet drawings.
What information is needed for a quotation for DS200TCEBG1ACE?
Provide clear front and rear nameplate photos, complete suffixes, quantity, installed platform, failure symptoms and delivery destination.
How should a stored spare for DS200TCEBG1ACE be evaluated?
Inspect packaging and connectors, review storage history, verify firmware and revision, and perform controlled bench or cabinet tests before return to service.