    Apter Power can quote DS200TCRAG1A and supply the applicable GE technical file for procurement review.

DS200TCRAG1A

/ 4.9
1001 reviews | Need a Specific Revision?
General Electric DS200TCRAG1A is a Mark V LM relay output board that receives contact-output commands from the digital I/O path and switches field circuits through DTBC or DTBD terminal boards.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for DS200TCRAG1A
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for DS200TCRAG1A

  • Manufacturer:
    General Electric
  • Part Number:
    DS200TCRAG1A
  • Product Family:
    GE Mark V/VI Driver Board
  • Product Type:
    Relay Output Board
  • Stock:
    1
  • Board Type:
    Relay output board
  • Relay Capacity:
    Up to 30 relays, K1-K30
  • Command Input:
    JO from TCDA or application-specific TCQE
  • Field Output:
    JS1-JS5 to DTBC/DTBD
  • Tariff Code:
    8537109090
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Relay Layout Command Paths Output Wiring Output Limits

Features:

  • Converts Mark V LM digital output commands into isolated relay contacts for field circuits.
  • Uses a 30-relay standard population with a distinct four-relay Q11 location-four arrangement.
  • Routes command input through JO and switched outputs through JS1 to JS5.
The board separates the command side from the terminal-board side, allowing a missing instruction and a failed field path to be traced from different connection points.

Two TCRA positions in each digital core divide the available contact outputs, so the physical slot determines which numbered circuits are present on one board.

Wetted power on J19 and J20 belongs only to particular location-five arrangements and should not be assumed on every relay-output position.

Apter Power supports post-EOL purchasing enquiries for General Electric DS200TCRAG1A Relay Output Board and can provide the applicable technical file.
General Electric DS200TCRAG1A Relay Output Board Manuals, Datasheets, Links Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

DS200TCRAG1A Population by Position

  • Standard population: A full board carries relays K1 through K30 for grouped contact outputs.
  • Core quantity: Each Mark V LM digital I/O core uses two TCRA board positions.
  • Q11 exception: Location four in the Q11 core contains four relays rather than the normal thirty.
  • Position identity: Relay count and assigned output numbers must be matched to the original core and slot.

Command Sources Reaching DS200TCRAG1A

  • TCDA source: Normal digital-core positions receive relay open and close commands from TCDA through JO.
  • TCQE source: The four-relay Q11 location-four board receives its JO commands from TCQE.
  • Input check: A missing command at JO belongs upstream of the relay board and its terminal connections.
  • Relay response: A valid JO command with no contact change narrows the fault to the selected relay or board-side output path.

Field Connections from DS200TCRAG1A

  • JS groups: JS1 through JS5 divide the switched relay outputs into terminal-board cable groups.
  • DTBC route: Selected board positions deliver their contact outputs to a DTBC terminal board.
  • DTBD route: Other positions use DTBD, including the location-five wetted-output arrangement.
  • AC feed: J19 and J20 can provide 120/240 V AC to outputs 47 and 48 in the supported Q11 or Q51 location-five positions.

Position-Dependent Output Boundaries

  • Solenoid sourcing: Permission to use relay groups as solenoid power sources depends on the installed core and board position.
  • Q21 restriction: The first 18 DS200TCRAG1A outputs in the Q21 core cannot use the solenoid-source arrangement.
  • Wetted contacts: J19 and J20 apply only to location five in the Q11 or Q51 core, not to every TCRA board.
  • Circuit assignment: Outputs 47 and 48 may feed ignition transformers where the cabinet design assigns that duty.
Description
General Electric DS200TCRAG1A is the TCRA relay output board used in the Mark V LM digital I/O cores. A fully populated position carries relays K1 through K30, and two TCRA boards serve each digital core.

One installation departs from that full population: the location-four DS200TCRAG1A in the Q11 core uses four relays and receives its commands from TCQE for the gas-manifold blow-off circuit.

At the other positions, TCDA sends relay open and close commands through JO, and DS200TCRAG1A returns the switched outputs through JS1 to JS5 toward DTBC or DTBD. Whether a relay group may source solenoid power depends on its core and board position; the first 18 outputs in Q21 are excluded from that arrangement.

Location five in the Q11 or Q51 core adds a separate wetted-contact option. On DS200TCRAG1A, J19 and J20 can supply 120/240 V AC to contact outputs 47 and 48 through DTBD, where those paths are commonly assigned to ignition transformers.
Alternative Names
DS200-TCRA-G1A DS200 TCRA G1A GE DS200TCRAG1A GE Mark V DS200TCRAG1A DS200TCRA G1A DS2O0TCRAG1A DS200TCRAGIA DS200TCRAG1A-GE
Technical notes
DS200TCRAG1A behavior depends on digital-core position: record JO source, JS1-JS5 destinations, relay population, and any J19/J20 wetted-output feed.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why can several DS200TCRAG1A contact outputs fail together?
DS200TCRAG1A receives grouped commands on JO and sends relay contacts through JS1-JS5, so a shared command cable or one terminal-board connection can affect multiple outputs.
Why does one DS200TCRAG1A in the Q11 core have only four relays?
The location-four DS200TCRAG1A in the Q11 core is a four-relay arrangement connected to TCQE for gas-manifold blow-off valve control.
Can every DS200TCRAG1A relay group be configured as a solenoid power source?
No. DS200TCRAG1A solenoid-source options depend on core and board position, and the first 18 outputs in Q21 are specifically excluded.
What should be checked when DS200TCRAG1A outputs 47 or 48 do not energize?
For a location-five DS200TCRAG1A in Q11 or Q51, verify the J19/J20 ac feed, DTBD path, and the assigned ignition-transformer circuit.
Why must the DS200TCRAG1A slot and core be recorded before replacement?
DS200TCRAG1A relay count, command source, terminal-board destination, and permitted solenoid-power arrangement change with the installed core and location.
How can a DS200TCRAG1A command problem be separated from a field-wiring problem?
Compare the intended command at the DS200TCRAG1A JO input with the corresponding relay state, then trace the selected JS1-JS5 output through DTBC or DTBD.
What confirms correct DS200TCRAG1A reconnection?
Each commanded DS200TCRAG1A relay should switch the documented DTBC/DTBD field circuit, with J19/J20 power present only where the site drawing assigns wetted outputs.