Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power can provide IC695CMM002 pricing, quotation assistance, and access to the applicable official General Electric technical documentation.

IC695CMM002

/ 4.9
1001 reviews | Need a Specific Revision?
General Electric IC695CMM002 is a PACSystems RX3i Two-Port Serial Communications Module for adding two isolated serial channels to an RX3i rack.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for IC695CMM002
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for IC695CMM002

  • Manufacturer:
    General Electric
  • Part Number:
    IC695CMM002
  • Product Family:
    GE PACSystems RX3i
  • Product Type:
    PACSystems RX3i Two-Port Serial Communications Module
  • Stock:
    1
  • Ports:
    2 independent isolated serial ports
  • Interfaces:
    RS-232 or RS-485/422, software selected
  • Protocols:
    Modbus Master/Slave, CCM Slave, DNP3 Master/Slave, Serial I/O
  • Baud Rates:
    1200 to 115200 bit/s
  • Handshaking:
    RTS/CTS and RFR/CTS for RS-232
  • Main Rack Capacity:
    Up to 6 modules
  • Remote Rack Capacity:
    Up to 4 per PNS-managed rack; 1 per CEP node
  • Configuration Software:
    PAC Machine Edition
  • Mounting:
    RX3i Universal Backplane
  • Diagnostics:
    Watchdog, RAM, flash, identity, status and LEDs
  • Isolation:
    Port-to-port and port-to-backplane
  • Approvals:
    CE, UL/CUL 508 and 1604, ATEX
  • Tariff Code:
    8537101190
  • Country of origin:
    United States
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Port Setup Protocols Rack Placement Diagnostics

Features:

  • Provides two independent isolated serial ports in one RX3i slot.
  • Selects RS-232 or RS-485/422 operation independently by software.
  • Runs Modbus, CCM, DNP3, or Serial I/O protocols with diagnostic reporting.
Two isolated channels let legacy serial devices be integrated without consuming the CPU embedded ports.

Protocol selection, baud rate, duplex behavior, and handshaking are configured in PAC Machine Edition rather than by module jumpers.

Remote-rack operation is available through supported RX3i PROFINET scanners and CEP carriers with the supported Modbus restriction.

General Electric IC695CMM002 PACSystems RX3i Two-Port Serial Communications Module is available for Apter Power quotation and official-documentation support.
General Electric IC695CMM002 PACSystems RX3i Two-Port Serial Communications Module Manuals, Datasheets, Links
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

IC695CMM002 Port Configuration

  • Electrical mode: Each channel independently selects RS-232 or RS-485/422.
  • Baud rate: Eight rates are available from 1200 to 115200 bit/s.
  • Flow control: RS-232 supports RTS/CTS and RFR/CTS hardware handshaking.
  • Isolation: The ports are isolated from each other and from the backplane.

IC695CMM002 Supported Protocol Roles

  • Modbus: Either Master or Slave can be assigned per port.
  • DNP3: Master and Slave roles are supported with the same-module DNP3 restriction.
  • CCM: CCM Slave operation supports compatible legacy connections.
  • Serial I/O: Application-directed Serial I/O is available for custom exchanges.

IC695CMM002 Installation Limits

  • Main backplane: As many as six serial modules may be installed.
  • PNS rack: A supported scanner-managed rack accepts up to four modules.
  • CEP node: A carrier-managed remote node accepts one module.
  • Hot insertion: Apply the required RX3i hot-insertion sequence and site safety precautions.

IC695CMM002 Service Indicators

  • Module faults: Watchdog, RAM, and flash failures are reported.
  • Port activity: LEDs expose module and communications status.
  • Identity data: The controller can read module identity and status.
  • Upgrade path: Onboard flash supports qualified firmware updates.
Description
IC695CMM002 adds two independently configurable, electrically isolated serial ports to a PACSystems RX3i controller or supported remote I/O station.

Each port on IC695CMM002 selects RS-232 or RS-485/422 in software and supports Modbus Master, Modbus Slave, CCM Slave, DNP3 Master, DNP3 Slave, or Serial I/O operation.

Selectable rates from 1200 to 115.2 kbit/s, port-to-port isolation, hardware handshaking, status LEDs, and module fault reporting support commissioning and service work on IC695CMM002.

The module occupies an RX3i Universal Backplane slot and supports controlled hot insertion and removal when qualified personnel apply the required RX3i safety sequence. Main-rack and remote-rack placement limits must be respected.
Revisions

Revision Part #

Also known as

IC695CMM002EJ
IC695CMM002-EJ, Series EJ, Rev EJ
IC695CMM002EH
IC695CMM002-EH, Series EH, Rev EH
IC695CMM002EG
IC695CMM002-EG, Series EG, Rev EG
IC695CMM002DF
IC695CMM002-DF, Series DF, Rev DF
IC695CMM002CF
IC695CMM002-CF, Series CF, Rev CF
IC695CMM002BF
IC695CMM002-BF, Series BF, Rev BF
IC695CMM002AF
IC695CMM002-AF, Series AF, Rev AF
IC695CMM002AE
IC695CMM002-AE, Series AE, Rev AE
IC695CMM002AD
IC695CMM002-AD, Series AD, Rev AD
IC695CMM002AC
IC695CMM002-AC, Series AC, Rev AC
IC695CMM002AB
IC695CMM002-AB, Series AB, Rev AB
IC695CMM002AA
IC695CMM002-AA, Series AA, Rev AA
Alternative Names
IC695 CMM002 IC695-CMM002 IC695CMM-002 GE IC695CMM002 GE Fanuc IC695CMM002 General Electric IC695CMM002 PACSystems RX3i IC695CMM002 Two-Port Serial Module IC695CMM002
Technical notes
IC695CMM002 remote-rack operation supports Modbus Master or Slave only, even though the same hardware offers additional protocols in the main rack.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why does IC695CMM002 reject a mixed DNP3 and Modbus port setup?
When any IC695CMM002 port uses DNP3 Master or Slave, every other port on that module must also use a DNP3 role; separate the Modbus traffic onto another module.
What should be checked when an IC695CMM002 port has no traffic?
Confirm the IC695CMM002 port mode, software-selected RS-232 or RS-485/422 interface, baud rate, cable pinout, and matching peer settings before replacing hardware.
Can IC695CMM002 be installed in a remote PROFINET rack?
Yes. IC695CMM002 is supported behind an RX3i PROFINET scanner or CEP carrier, but remote operation is limited to Modbus Master or Modbus Slave.
Why does RTS/CTS behavior differ between two IC695CMM002 units?
IC695CMM002 hardware versions 1.34 and 2.0 use different flow-control behavior, so check the complete hardware and firmware revision.
How many IC695CMM002 modules can be placed in one main rack?
The RX3i main backplane supports up to six IC695CMM002 serial modules, subject to slot, power-budget, and CPU compatibility checks.
Can IC695CMM002 be inserted without shutting down the rack?
IC695CMM002 supports controlled hot insertion and removal when qualified personnel apply the required RX3i safety and maintenance sequence.
What software is needed to configure half-duplex flow control on IC695CMM002?
Half-duplex flow control on IC695CMM002 requires firmware 1.32 or later and PAC Machine Edition 5.90 SP1 SIM 6 or later.