    Apter Power can provide IC695CMM004 pricing, quotation assistance, and access to the applicable official General Electric technical documentation.

IC695CMM004

/ 4.9
1001 reviews | Need a Specific Revision?
General Electric IC695CMM004 is a PACSystems RX3i Four-Port Serial Communications Module for adding four isolated serial channels to an RX3i rack.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for IC695CMM004
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for IC695CMM004

  • Manufacturer:
    General Electric
  • Part Number:
    IC695CMM004
  • Product Family:
    GE PACSystems RX3i
  • Product Type:
    PACSystems RX3i Four-Port Serial Communications Module
  • Stock:
    1
  • Ports:
    4 independent isolated serial ports
  • Interfaces:
    RS-232 or RS-485/422, software selected
  • Protocols:
    Modbus Master/Slave, CCM Slave, DNP3 Master/Slave, Serial I/O
  • Baud Rates:
    1200 to 115200 bit/s
  • Handshaking:
    RTS/CTS and RFR/CTS for RS-232
  • Main Rack Capacity:
    Up to 6 modules
  • Remote Rack Capacity:
    Up to 4 per PNS-managed rack; 1 per CEP node
  • Configuration Software:
    PAC Machine Edition
  • Mounting:
    RX3i Universal Backplane
  • Diagnostics:
    Watchdog, RAM, flash, identity, status and LEDs
  • Isolation:
    Port-to-port and port-to-backplane
  • Approvals:
    CE, UL/CUL 508 and 1604, ATEX
  • Tariff Code:
    8537101190
  • Country of origin:
    United States
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Channel Setup Protocol Rules Remote Use Status Tools

Features:

  • Consolidates four independently isolated serial ports into one RX3i slot.
  • Supports software-selected RS-232 and RS-485/422 electrical modes.
  • Combines configurable industrial protocols with status and fault diagnostics.
Four channels reduce slot usage in applications with several meters, drives, RTUs, or other serial devices.

Each port has its own communication settings, while DNP3 use imposes a same-module DNP3 protocol restriction.

Supported remote placement expands serial connectivity near field equipment while limiting those remote ports to Modbus roles.

General Electric IC695CMM004 PACSystems RX3i Four-Port Serial Communications Module is available for Apter Power quotation and official-documentation support.
General Electric IC695CMM004 PACSystems RX3i Four-Port Serial Communications Module Manuals, Datasheets, Links
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

IC695CMM004 Four-Channel Setup

  • Independent ports: Every channel has its own protocol and line settings.
  • Electrical standard: RS-232 or RS-485/422 is selected in software.
  • Rate range: Baud rates extend from 1200 through 115200 bit/s.
  • Handshake lines: RS-232 supports RTS/CTS and RFR/CTS control.

IC695CMM004 Protocol Coordination

  • Modbus: Master and Slave roles can coexist where allowed.
  • DNP3 restriction: Using DNP3 on one channel restricts the others to DNP3.
  • CCM Slave: Legacy CCM Slave devices are supported.
  • Serial I/O: Custom application exchanges use the Serial I/O mode.

IC695CMM004 Remote-Rack Operation

  • PNS placement: A scanner-managed rack accepts up to four serial modules.
  • CEP placement: A CEP remote node accepts one serial module.
  • Remote protocols: Only Modbus Master and Slave are supported remotely.
  • PME requirement: Current supported PAC Machine Edition is used for configuration.

IC695CMM004 Diagnostics and Maintenance

  • LED feedback: Front indicators show module and communication state.
  • Fault reporting: Watchdog, RAM, and flash failures reach the controller.
  • Hot service: Qualified personnel may use the qualified RX3i hot-insertion procedure.
  • Firmware: Onboard flash supports manufacturer-authorized updates.
Description
IC695CMM004 places four independent isolated serial interfaces in a single PACSystems RX3i Universal Backplane slot for dense legacy-device integration.

The four channels on IC695CMM004 can each select RS-232 or RS-485/422 and use Modbus, CCM Slave, DNP3, or Serial I/O protocols under PAC Machine Edition configuration.

Port isolation, configurable handshaking, rates through 115.2 kbit/s, status LEDs, and module-level fault reporting allow IC695CMM004 to consolidate serial connectivity without sacrificing diagnostics.

Placement rules distinguish the main backplane from scanner-managed or CEP-managed remote locations. Low-temperature and conformal-coated variants are separate order configurations, not base-model revisions.
Revisions

Revision Part #

Also known as

IC695CMM004EJ
IC695CMM004-EJ, Series EJ, Rev EJ
IC695CMM004EH
IC695CMM004-EH, Series EH, Rev EH
IC695CMM004EG
IC695CMM004-EG, Series EG, Rev EG
IC695CMM004DF
IC695CMM004-DF, Series DF, Rev DF
IC695CMM004CF
IC695CMM004-CF, Series CF, Rev CF
IC695CMM004BF
IC695CMM004-BF, Series BF, Rev BF
IC695CMM004AF
IC695CMM004-AF, Series AF, Rev AF
IC695CMM004AE
IC695CMM004-AE, Series AE, Rev AE
IC695CMM004AD
IC695CMM004-AD, Series AD, Rev AD
IC695CMM004AC
IC695CMM004-AC, Series AC, Rev AC
IC695CMM004AB
IC695CMM004-AB, Series AB, Rev AB
IC695CMM004AA
IC695CMM004-AA, Series AA, Rev AA
Alternative Names
IC695 CMM004 IC695-CMM004 IC695CMM-004 GE IC695CMM004 GE Fanuc IC695CMM004 General Electric IC695CMM004 PACSystems RX3i IC695CMM004 Four-Port Serial Module IC695CMM004
Technical notes
IC695CMM004 places four isolated channels in one slot, but a DNP3 assignment restricts every remaining port on that module to DNP3.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why are ports 3 and 4 unavailable after replacing a two-port module with IC695CMM004?
Update the PAC Machine Edition hardware configuration to IC695CMM004 and download it so all four physical channels are instantiated.
Can the four IC695CMM004 ports use different electrical standards?
For IC695CMM004, yes. Configure RS-232 or RS-485/422 independently for each channel, then match the cable and duplex setting to that port.
Why does a remote-rack IC695CMM004 reject a configured DNP3 or CCM channel?
For IC695CMM004, remote PNS- or CEP-managed use is limited to supported Modbus Master or Slave roles; place other protocol channels in the supported main-rack arrangement.
What should be checked when only one IC695CMM004 channel stops communicating?
For IC695CMM004, compare that port’s LED state, electrical mode, baud rate, parity, stop bits, duplex setting, handshaking, and cable pinout with the connected device.
Can IC695CMM004 mix DNP3 and non-DNP3 protocols on one module?
For IC695CMM004, no. If any port is configured for DNP3 Master or Slave, the remaining ports on that module must also use a DNP3 role.
How many IC695CMM004 modules can a main RX3i rack accept?
For IC695CMM004, the main-rack limit is six serial communications modules; also verify slot availability and the complete rack power budget.
What changes when an IC695CMM004 RS-485 port is changed to half duplex?
For IC695CMM004, select two-wire operation and verify the shared transmit/receive pair, polarity, termination, and turnaround timing against the attached device.