GE IC698ETM001
GE IC698ETM001
GE IC698ETM001
GE IC698ETM001
GE IC698ETM001
GE IC698ETM001
Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
How We Verify Your Order
Before dispatch, we confirm the exact model, revision, condition, inspection requirements and shipping documents for your order.
See a real on-site verification case >>
  • Lifecycle status

    Active Mature

IC698ETM001

/ 4.9
1001 reviews | Need a Specific Revision?
GE IC698ETM001 adds switched dual-port Ethernet connectivity to an RX7i main rack for controller data exchange, programming and network diagnostics.
In Stock
Ships by Saturday, November 14
Fast Shipping Available
Get a quick price for IC698ETM001
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for IC698ETM001

  • Manufacturer:
    General Electric
  • Part Number:
    IC698ETM001
  • Product Family:
    GE PACSystems RX7i
  • Product Type:
    Ethernet Interface Module
  • Stock:
    1
  • Network Ports:
    Two switched RJ45 ports
  • Port Speed:
    10/100 Mbit/s, auto-negotiating
  • Media:
    10Base-T or 100Base-TX copper Ethernet
  • Supported Services:
    EGD, SRTP, programming and station manager
  • Rack Position:
    RX7i main rack
  • Interfaces Per Rack:
    Three maximum
  • Topology:
    Tree or switched linear layout; ring connection prohibited
  • Backplane Demand:
    1.5 A at 5 VDC documented in installation data
  • Tariff Code:
    8517629990
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Address Record Topology Control Communication Proof Application
  • Two internally switched 10/100 Ethernet ports
  • Ethernet Global Data and SRTP support
  • Station Manager network diagnostics

IC698ETM001 is an RX7i Ethernet interface module that adds network connectivity for controller communications and industrial data exchange.

Its two internally switched ports support Ethernet Global Data, SRTP services and Station Manager diagnostic access.

Installation planning should verify the IP configuration, network topology, EGD exchange settings and switch connections to prevent address conflicts, communication loss or unintended network loops.

Availability, condition, price, and shipping time for IC698ETM001 are confirmed during quotation.

General Electric IC698ETM001 Ethernet Interface Module Manuals, Datasheets, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • Capture IP, subnet, gateway and station-manager data
  • Export every EGD producer and consumer definition
  • Record hardware, boot and firmware releases
  • Use a supported tree or switched path
  • Do not close the two ports into a ring
  • Verify switch and cable routes before reconnecting
  • Test programming and SRTP access
  • Validate each EGD exchange and status counter
  • Confirm recovery after a controlled path interruption
  • Additional RX7i Ethernet communications
  • Ethernet Global Data exchange networks
  • Revision-controlled IC698ETM001 interface replacement
Description
IC698ETM001 provides two auto-negotiating 10/100Base-TX ports connected through an internal switch. It supports Ethernet Global Data, SRTP communications, programming access and station-manager diagnostics.

Up to three interfaces can be installed in an RX7i main rack. The manufacturer specifies tree-style switched layouts and warns that the two ports must not be used to form a network ring.

Network addresses, exchange definitions and the complete release suffix must be preserved during replacement. Firmware and boot-code requirements vary across the documented hardware releases.
Revisions

Revision Part #

Also known as

IC698ETM001AA
IC698ETM001-AA, Series AA, Rev AA
IC698ETM001AB
IC698ETM001-AB, Series AB, Rev AB
IC698ETM001AC
IC698ETM001-AC, Series AC, Rev AC
IC698ETM001BC
IC698ETM001-BC, Series BC, Rev BC
IC698ETM001CD
IC698ETM001-CD, Series CD, Rev CD
IC698ETM001CE
IC698ETM001-CE, Series CE, Rev CE
IC698ETM001CF
IC698ETM001-CF, Series CF, Rev CF
IC698ETM001DG
IC698ETM001-DG, Series DG, Rev DG
IC698ETM001DH
IC698ETM001-DH, Series DH, Rev DH
IC698ETM001DJ
IC698ETM001-DJ, Series DJ, Rev DJ
IC698ETM001DK
IC698ETM001-DK, Series DK, Rev DK
IC698ETM001EK
IC698ETM001-EK, Series EK, Rev EK
IC698ETM001EL
IC698ETM001-EL, Series EL, Rev EL
IC698ETM001EM
IC698ETM001-EM, Series EM, Rev EM
IC698ETM001EN
IC698ETM001-EN, Series EN, Rev EN
IC698ETM001EP
IC698ETM001-EP, Series EP, Rev EP
IC698ETM001ER
IC698ETM001-ER, Series ER, Rev ER
IC698ETM001ES
IC698ETM001-ES, Series ES, Rev ES
IC698ETM001ET
IC698ETM001-ET, Series ET, Rev ET
IC698ETM001FT
IC698ETM001-FT, Series FT, Rev FT
IC698ETM001FU
IC698ETM001-FU, Series FU, Rev FU
Alternative Names
GE IC698ETM001 GE Fanuc IC698ETM001 IC 698 ETM 001 PACSystems RX7i IC698ETM001 IC698ETM001 Dual-Port Ethernet
Technical notes
IC698ETM001 must remain in a loop-free tree topology, retain its exact IP and EGD configuration, match supported firmware and release suffixes, and pass exchange recovery testing after installation.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Can GE IC698ETM001 ports be connected as an Ethernet ring?
No. The manufacturer warns against joining the two switched ports into a ring. Use a supported tree or switched topology and prevent unintended network loops.
What settings should be saved before replacing GE IC698ETM001?
Record the IP configuration, subnet and gateway, EGD exchanges, SRTP connections, station-manager data, switch path and the full hardware and firmware release.
How many GE IC698ETM001 modules can an RX7i rack use?
The manufacturer allows up to three in the main rack. Confirm slot allocation, rack power and controller firmware before changing the installed count.
Why can GE IC698ETM001 show link but exchange no controller data?
A physical link does not prove configuration. Check IP duplication, subnet, EGD producer and consumer definitions, exchange identifiers, controller ownership and partner status.
Can an early GE IC698ETM001 be upgraded to AC firmware?
GFK-2266B documents an upgrade path from AA or AB to AC. Confirm the installed suffix and follow the release-specific boot and firmware procedure without interruption.
How should GE IC698ETM001 network recovery be tested?
Prove programming access, each EGD exchange and SRTP connection, station-manager diagnostics and recovery after a controlled interruption on every connected path.
What should be checked when GE IC698ETM001 repeatedly resets?
Review rack power, module logs, firmware compatibility, duplicated addresses, excessive or looping traffic, connector condition and controller fault records before replacing the hardware.