IC754VBI06MTD

/ 4.9
1001 reviews | Need a Specific Revision?
General Electric IC754VBI06MTD is a QuickPanel View Intermediate 6-inch monochrome touch HMI with a blank bezel for machine visualization and operator input.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for IC754VBI06MTD
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for IC754VBI06MTD

  • Manufacturer:
    General Electric
  • Part Number:
    IC754VBI06MTD
  • Product Family:
    GE QuickPanel
  • Product Type:
    QuickPanel View Intermediate 6-Inch Monochrome Touch HMI with Blank Bezel
  • Stock:
    1
  • Display:
    5.75-inch monochrome FSTN
  • Resolution:
    320 x 240 pixels
  • Gray Levels:
    256
  • Touchscreen:
    12-bit resistive, 320 x 240 calibrated cells
  • Processor:
    Intel XScale PXA255, 300 MHz
  • Operating System:
    Microsoft Windows CE.NET
  • DRAM:
    32 MB
  • Flash Memory:
    32 MB
  • Retentive Memory:
    512 KB battery-backed SRAM
  • Ethernet:
    IEEE 802.3 10/100BaseT, RJ45
  • Serial Port:
    COM1 EIA232C/EIA485, 300 to 115200 bps
  • CompactFlash:
    One Type 2 slot
  • Expansion Bus:
    One slot
  • Input Voltage:
    10.8 to 30 VDC
  • Power Consumption:
    12 W
  • Operating Temperature:
    -10 to 60 °C
  • Storage Temperature:
    -20 to 70 °C
  • Panel Rating:
    NEMA 4, 4X, and 12; IP65 equivalent
  • Backup Battery:
    CR2032, 3 V, 190 mAh
  • Weight:
    2.5 lbs (1.16 kg)
  • Estimated shipping dimensions:
    158 x 126 x 70 mm
  • Tariff Code:
    8537109170
  • Country of origin:
    United States
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Connectivity Memory Maintenance Installation

Features:

  • Presents a compact monochrome operator interface with a customer-brandable blank bezel.
  • Runs the Intermediate Machine Edition View environment on an embedded Windows CE.NET platform.
  • Combines Ethernet, selectable serial communication, CompactFlash, and fieldbus expansion in one panel unit.
The passive monochrome display provides 256 gray levels at 320 x 240 resolution, allowing status screens, trends, alarms, and operator controls to share the same touch surface.

Its memory architecture separates temporary program execution from nonvolatile application storage and retained process data, reducing the risk that a normal restart erases essential runtime information.

Front power and programmable status indicators, a replaceable communications fuse, and a low-battery warning help maintenance personnel distinguish common hardware conditions before opening the enclosure.

General Electric IC754VBI06MTD QuickPanel View Intermediate 6-Inch Monochrome Touch HMI with Blank Bezel is available for Apter Power quotation and official-documentation support.
General Electric IC754VBI06MTD QuickPanel View Intermediate 6-Inch Monochrome Touch HMI with Blank Bezel Manuals, Datasheets, Links

IC754VBI06MTD Communication Paths

  • Ethernet wiring: Use a crossover cable for a direct workstation link and straight-through Category 5 cabling through a network hub.
  • Serial selection: COM1 supports EIA232C or EIA485 operation and can serve a direct, dial-up, or application-created connection.
  • EIA485 termination: At the final network node, link the documented termination pins and use twisted-pair cable.
  • Fieldbus options: The rear bus accepts supported Genius, DeviceNet Slave, or PROFIBUS Slave interfaces.

IC754VBI06MTD Memory Handling

  • Flash storage: The operating image and deployed project reside in nonvolatile flash.
  • Retentive files: Battery-backed SRAM is available for data that must remain after main power is removed.
  • Program workspace: DRAM is divided between running programs and temporary object storage.
  • Expansion: A Type 2 CompactFlash card can add removable file capacity.

IC754VBI06MTD Service Checks

  • Touch drift: Run Stylus calibration with a blunt stylus and save the result with Backup.
  • Low battery: A taskbar warning indicates that the CR2032 backup cell requires attention.
  • Backlight state: An amber power indicator identifies a failed display backlight.
  • Safe access: Disconnect power and observe electrostatic precautions before opening the rear cover.

IC754VBI06MTD Panel Requirements

  • Cutout: Prepare a 156 x 123.5 mm panel opening with the specified positive tolerance.
  • Panel thickness: Use a mounting surface from 1.6 to 5 mm thick.
  • Clamp torque: Tighten the four bracket screws within 0.3 to 0.5 N·m.
  • Seal: Keep the bezel gasket seated and undamaged to preserve the front rating.
Description
IC754VBI06MTD combines a 5.75-inch FSTN screen and calibrated resistive touch layer in the compact 6-inch QuickPanel View enclosure. The blank bezel supports machine builders that apply their own equipment identity around the operator display.

The communication layout on IC754VBI06MTD provides a 10/100BaseT Ethernet port and a configurable EIA232C/EIA485 serial channel. CompactFlash and the rear expansion bus extend storage or add a supported fieldbus interface without enlarging the panel opening.

Retained machine data can be placed in battery-backed SRAM on IC754VBI06MTD. The separate backup utility commits registry and desktop changes to flash so calibrated touch settings and network configuration survive a power cycle.

Inside IC754VBI06MTD, the PXA255 processor runs the Windows CE.NET platform and the Intermediate Machine Edition View runtime. Programs execute from DRAM, while the flash file system retains the operating image and deployed visualization project.
Alternative Names
IC754 VBI06 MTD IC754-VBI06-MTD IC754 VBI-06MTD GE IC754VBI06MTD GE Fanuc IC754VBI06MTD QuickPanel View IC754VBI06MTD 1C754VBI06MTD IC754VBIO6MTD
Technical notes
IC754VBI06MTD uses a CR2032 cell for retained SRAM; loss of retained data after shutdown indicates battery service rather than flash-memory failure.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How should touch drift be corrected on IC754VBI06MTD?
Open Stylus on IC754VBI06MTD, run Recalibrate with a blunt stylus, accept the crosshair sequence, and complete Backup before cycling power.
Why does IC754VBI06MTD lose a changed network address after restart?
Registry changes on IC754VBI06MTD are not persistent until the Backup utility finishes; save the setting and wait for completion before removing power.
What cable is needed for a direct IC754VBI06MTD-to-PC Ethernet connection?
Use a crossover Ethernet cable between IC754VBI06MTD and a workstation; use straight-through cabling when a hub or switch is between them.
What should be checked when IC754VBI06MTD cannot save new runtime files?
Check free flash and CompactFlash capacity on IC754VBI06MTD, then confirm that storage memory in System Properties has not been allocated too low.
How is the EIA485 end node terminated on IC754VBI06MTD?
Use twisted-pair wiring and enable the documented receive termination at the last IC754VBI06MTD node by linking the specified COM1 pins.
Why is the IC754VBI06MTD power LED amber although the HMI still starts?
On IC754VBI06MTD, an amber power-status indication points to a failed backlight; check the display and plan service before relying on operator visibility.
What must be removed before mounting IC754VBI06MTD through the cutout?
Disconnect the power plug, communication leads, and CompactFlash card from IC754VBI06MTD so they are not damaged as the enclosure passes through the panel.