Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    A sourcing request for IC600CB526 may be paired with an Apter Power quotation and accessible original GE information for the Series Six CPU file.

IC600CB526

/ 4.9
1001 reviews | Need a Specific Revision?
General Electric IC600CB526 is an Expanded Logic Control Module that extends Series Six processing with broader I/O, register, floating-point, diagnostic, and communication functions.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for IC600CB526
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for IC600CB526

  • Manufacturer:
    General Electric
  • Part Number:
    IC600CB526
  • Product Family:
    GE Series Six Plus
  • Product Type:
    Expanded Logic Control Module
  • Stock:
    1
  • Function Set:
    Expanded
  • Core Circuits:
    System clock, microprogram sequencer and PROM
  • Processor Link:
    Ribbon cable to the Arithmetic Control Module
  • Inherited Functions:
    Advanced logic, signed arithmetic, data handling and user I/O control
  • Expanded Addressing:
    Extended I/O and register ranges
  • Additional Operations:
    Floating point and communication-control functions
  • Diagnostic Support:
    Genius I/O diagnostic functions
  • CPU Compatibility:
    Supported Series Six and Series Six Plus CPU racks
  • Backplane Supply:
    5 VDC
  • Current Draw:
    650 mA
  • Load Units:
    12 at +5 VDC
  • Operating Temperature:
    0 to 60 deg C
  • Storage Temperature:
    -20 to 70 deg C
  • Relative Humidity:
    5% to 95%, noncondensing
  • Estimated shipping dimensions:
    31.7x28.0x3.1cm
  • Tariff Code:
    8538900000
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Addressing Calculations Diagnostics CPU Link

Features:

  • Provides the Expanded Series Six CPU instruction set.
  • Adds broader I/O and register addressing with floating-point support.
  • Extends Genius diagnostic and communication-control capability.
IC600CB526 supplies the microprogram and timing controls required for expanded Series Six processing.

Its added functions affect the application, memory references, I/O architecture, and communication behavior as a connected system.

Commissioning must prove those paths, not only the CPU CHECK lamp.

For General Electric IC600CB526 Expanded Logic Control Module pricing and original manufacturer documentation support, contact Apter Power.
General Electric IC600CB526 Expanded Logic Control Module Manuals, Datasheets, Links Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Validate every expanded reference

  • Register handling: IC600CB526 permits larger I/O and register ranges than a basic processor build.
  • Program context: Export the channel map and inspect the ladder program for high references before hardware work.
  • Expanded range: Confirm that the memory configuration and installed I/O transmitters support the intended range.
  • Functional proof: Avoid assuming that a successful load proves all references are reachable.
  • Output control: Test representative points on each used channel before outputs return.

Exercise the instructions that distinguish the module

  • Expanded instructions: Floating-point and additional data-handling operations are part of the IC600CB526 Expanded set.
  • Operational effect: Identify where those results affect limits, sequencing, or communication.
  • Result comparison: After replacement, compare selected calculations with known process values and preserved reference data.
  • Release criterion: A difference should be investigated before automatic control resumes.

Keep Genius and communication paths in the test plan

  • Diagnostic result: IC600CB526 supports Genius I/O diagnostics and added communication-control functions.
  • Indicator meaning: Capture normal status words and request behavior from the installed application.
  • Remote logic: A fault in a remote path can appear only after the CPU reaches the related logic.
  • Operational effect: Run those sections deliberately during commissioning.
  • Commissioning record: Retain the final status record with the restored checksum.

Inspect the processing pair and ribbon

  • Ribbon connection: The module provides microprogram control to the Arithmetic Control board through a ribbon cable.
  • Operational effect: Remove power before disturbing either connection.
  • Connector fit: Check orientation, engagement, and strain, then compare both board suffixes with the approved CPU build.
  • Broader diagnosis: If execution remains unstable, diagnose power and memory along with IC600CB526 rather than exchanging multiple boards at once.
Description
General Electric IC600CB526 is the Expanded Logic Control Module for Series Six and Series Six Plus CPUs. Its clock, microprogram sequencer, and PROM provide the control and timing stream used throughout the processor.

The Expanded function set retains the Advanced capabilities while adding expanded I/O and register addressing, floating-point operations, Genius I/O diagnostic support, and additional communication-control instructions.

A ribbon cable carries microprogram instructions from IC600CB526 to the Arithmetic Control Module. Running the CPU without that connection can lead to unpredictable execution, so ribbon integrity belongs in every troubleshooting sequence.

A replacement must be checked against the program instructions, memory configuration, I/O addressing mode, and installed communication options. A successful power-up is not sufficient until expanded references and diagnostic paths have been exercised.
Alternative Names
IC600-CB526 IC600CB-526 IC 600 CB 526 GE IC600CB526 GE Fanuc IC600CB526 General Electric IC600CB526 Series Six IC600CB526 IC600CB526 Expanded Logic
Technical notes
Preserve IC600CB526 expanded references, Arithmetic Control pairing, ribbon state, memory build, program checksum, Genius diagnostics, and communication requests before replacement.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How can an engineer confirm that IC600CB526 is required?
Review the program for expanded I/O or register references, floating-point instructions, Genius diagnostics, and communication functions that depend on the IC600CB526 Expanded set.
What should be compared before swapping IC600CB526?
Compare the full IC600CB526 suffix, CPU rack, Arithmetic Control partner, ribbon cable, memory capacity, addressing mode, software tools, and all expanded instructions used.
Why may a CPU power up but still fail after IC600CB526 replacement?
IC600CB526 can pass an initial hardware check while an incompatible function set, memory arrangement, or expanded reference later fails during application execution.
How should the ribbon connection on IC600CB526 be serviced?
Remove rack power, inspect both ribbon connectors and orientation, seat the cable without strain, and do not operate IC600CB526 with the link disconnected.
What needs testing before enabling outputs with IC600CB526?
Exercise the IC600CB526 expanded I/O references, critical calculations, communication requests, Genius diagnostics, retained data, and stop-to-run sequence under controlled conditions.
Why is the saved I/O map important for IC600CB526?
The Expanded function set can address a larger I/O structure. The IC600CB526 installation must be validated against the actual channel and reference plan to prevent overlap.
What should accompany an IC600CB526 failure report?
Include the IC600CB526 suffix, rack and memory build, CPU indicators, instruction or reference at failure, checksum, software release, ribbon condition, and any diagnostic message.

Product Browsing History