IC600PM500

/ 4.9
1001 reviews | Need a Specific Revision?
General Electric IC600PM500 is a Series Six CPU/DPU wide-range AC power supply that delivers regulated +5, +12, and -12 VDC to the rack backplane.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for IC600PM500
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for IC600PM500

  • Manufacturer:
    General Electric
  • Part Number:
    IC600PM500
  • Product Family:
    GE Series Six Plus
  • Product Type:
    Wide-Range AC CPU/DPU Power Supply Module
  • Stock:
    1
  • Rack use:
    CPU or DPU rack
  • Input voltage:
    95 to 260 VAC
  • Input frequency:
    47 to 63 Hz
  • Maximum input power:
    250 VA
  • +5 VDC output:
    16.5 A maximum
  • +12 VDC output:
    1.5 A maximum
  • -12 VDC output:
    1.0 A maximum
  • Total output power:
    Less than 90 W across all outputs
  • Auxiliary battery input:
    8 to 28 VDC
  • Allowable interruption:
    33 ms minimum at 115 VAC
  • Power indicator:
    On when all three DC outputs are within tolerance
  • Processor control:
    CPU RUN/STOP keyswitch
  • Memory control:
    MEMORY PROTECT/WRITE keyswitch
  • Main disconnect:
    Power switch and fuse
  • Alarm contacts:
    Two isolated NO/NC relay sets
  • Alarm contact load:
    Resistive, maximum 1 A at 115 VAC or 28 VDC
  • Normal alarm state:
    Relays energized
  • Rack location:
    Extreme right side of CPU/DPU rack
  • Operating temperature:
    0 to 60 degrees C
  • Storage temperature:
    -20 to 80 degrees C
  • Humidity:
    5 to 95% non-condensing
  • Noise immunity:
    NEMA ICS 2-230 and ANSI C37.90A
  • Estimated shipping dimensions:
    317 x 229 x 70 mm (12.46 x 9.00 x 2.75 in)
  • Tariff Code:
    8504409999
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Input Outputs Controls Alarms

Features:

  • IC600PM500 accepts 95–260 VAC at 47–63 Hz.
  • Three regulated rails deliver +5, +12, and -12 VDC.
  • Front controls combine processor mode and memory protection.
The supply powers either a Series Six CPU rack or a Data Processor Unit rack from a wide-range AC source.

Its POWER indicator confirms that all three DC output rails are operating within tolerance.

Two isolated alarm relay sets and an optional auxiliary-battery input support monitored and backed installations.

Quotation support for the General Electric IC600PM500 Wide-Range AC CPU/DPU Power Supply is available from Apter Power together with relevant manufacturer manuals or product documentation.
General Electric IC600PM500 Wide-Range AC CPU/DPU Power Supply Manuals, Datasheets, Links Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Wide-range AC input and interruption tolerance

  • Voltage: IC600PM500 accepts 95 to 260 VAC.
  • Frequency: The documented operating range is 47 to 63 Hz.
  • Input demand: Maximum input power is 250 VA.
  • Ride-through: Allowable interruption is at least 33 ms at 115 VAC.

Regulated backplane output rails

  • +5 VDC: The main logic rail supplies up to 16.5 A.
  • +12 VDC: The positive auxiliary rail supplies up to 1.5 A.
  • -12 VDC: The negative auxiliary rail supplies up to 1.0 A.
  • Total: Combined output remains below 90 W.

Front-panel operating controls

  • Main power: A front switch and fuse control the incoming AC supply.
  • Processor mode: The CPU RUN/STOP keyswitch sets processor operation.
  • Memory access: The MEMORY PROTECT/WRITE keyswitch controls program changes.
  • Status: POWER is lit when all three DC rails are within tolerance.

Alarm contacts and auxiliary backup

  • Contact sets: Two isolated relays provide NO and NC outputs.
  • Normal state: Both alarm relays are energized during normal operation.
  • Contact rating: A resistive load may be up to 1 A at 115 VAC or 28 VDC.
  • Backup input: An isolated 8 to 28 VDC source can feed the auxiliary-battery circuit.
Description
The General Electric IC600PM500 CPU/DPU Power Supply accepts 95–260 VAC at 47–63 Hz and supplies regulated rack power for a Series Six CPU or Data Processor Unit.

Three regulated outputs give IC600PM500 up to 16.5 A at +5 VDC, 1.5 A at +12 VDC, and 1.0 A at -12 VDC, with combined output power held below 90 W.

Front-panel controls on IC600PM500 combine the main power switch and fuse with CPU RUN/STOP and MEMORY PROTECT/WRITE key switches. The POWER indicator confirms that all three DC rails are within tolerance.

Two isolated alarm-contact sets and an 8–28 VDC auxiliary-battery input extend IC600PM500 for monitored installations and backed operation. The module occupies the extreme right position of a CPU or DPU rack.
Revisions

Revision Part #

Also known as

IC600PM500B
IC600PM500-B, Series B, Rev B
Alternative Names
IC600 PM500 IC600-PM500 IC-600-PM-500 GE IC600PM500 General Electric IC600PM500 Series Six CPU/DPU Power Supply IC600PM50O IC600PMS00
Technical notes
Keep the IC600PM500 auxiliary-battery circuit isolated from the rest of the system; otherwise the backup source can be short-circuited.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why can IC600PM500 remain dark even when AC wiring is present?
IC600PM500 needs 95-260 VAC at 47-63 Hz, and its POWER light stays off if any regulated output remains below tolerance.
How does IC600PM500 separate a rack-power alarm from normal operation?
IC600PM500 energizes its isolated alarm relays in the normal state; a supply fault changes the NO/NC contact states for external monitoring.
What can short the IC600PM500 auxiliary backup source during service?
The IC600PM500 auxiliary-battery circuit must stay isolated from the rest of the system, or an unintended common can short the backup source.
Why must field devices use a separate supply from IC600PM500?
IC600PM500 powers the Series Six rack backplane; input and output field devices still require their own correctly rated external power.
What rack-load problem can cause unstable IC600PM500 outputs?
An IC600PM500 rack must remain within 16.5 A at +5 VDC, 1.5 A at +12 VDC, 1.0 A at -12 VDC, and 90 W total.
Where should IC600PM500 be fitted during a power-supply replacement?
IC600PM500 mounts at the extreme right of the Series Six CPU or DPU rack, with internal and front-panel connections restored before restart.
How much interruption can IC600PM500 ride through at 115 VAC?
IC600PM500 maintains operation through at least a 33 ms interruption at 115 VAC, so longer input loss can drop the regulated rails.