Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail info@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power provides documentation, procurement support and integration guidance for General Electric IC200ALG263.

IC200ALG263

/ 4.9
1001 reviews | Need a Specific Revision?
General Electric IC200ALG263 is a 15-channel single-ended VersaMax voltage input module for high-density ±10 V signal acquisition.
In Stock
Ships by Thursday, October 1
Fast Shipping Available
Get a quick price for IC200ALG263
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for IC200ALG263

  • Manufacturer:
    General Electric
  • Part Number:
    IC200ALG263
  • Product Family:
    GE VersaMax
  • Product Type:
    Analog Input Module
  • Stock:
    1
  • Input Channels:
    15 single-ended voltage inputs
  • Input Range:
    -10 to +10 V
  • Resolution:
    15-bit; 0.3125 mV per count
  • Update Rate:
    7.5 ms
  • Input Impedance:
    100 kΩ minimum
  • Common Return:
    One shared group return
  • 5 V Backplane Current:
    150 mA maximum
  • Isolation:
    1500 VAC for 1 minute; 250 VAC continuous input-to-logic/frame
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Fault Response Common Return Data Handling Applications

Features:

  • Fifteen single-ended bipolar-voltage inputs
  • One common return for the complete input group
  • Internal A/D path checking with a defined stop-scan response
The General Electric IC200ALG263 part number identifies the fifteen-channel voltage option in the VersaMax analog input family.

A dense group of bipolar sources is converted into fifteen ordered words while a known-stimulus test checks the internal A/D path.

All source references must suit the shared A17 return, and shield connections follow the installed carrier style. The controller configuration also defines whether lost module data changes to a default value or retains the last reading.

The General Electric IC200ALG263 Voltage Input Module may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
General Electric IC200ALG263 Voltage Input Module Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

A/D Self-Test and Recovery

  • Known stimulus: The module checks its conversion path by applying an internal reference to the A/D converter.
  • Failure threshold: Three consecutive unexpected test results cause the module to stop scanning.
  • Local indication: The OK LED turns off when the self-test creates an Internal Hardware fault.
  • Recovery action: The manual directs a power cycle and module replacement if the same internal fault returns.

Shared Reference and Shield Connections

  • Signal reference: All fifteen voltage inputs measure their sources against the A17 common terminal.
  • Return expansion: An auxiliary terminal strip and shorting bar can provide additional common connection points.
  • Isolation boundary: The input group is isolated from logic and frame but not between its individual channels.
  • Shield routing: Cable shields connect according to the grounding arrangement shown for the installed carrier.

Word Mapping and Loss-State Behavior

  • Channel order: Fifteen returned words preserve the sequence of the fifteen physical voltage terminals.
  • Bipolar scale: Controller logic converts signed counts across the documented –10 to +10 V span.
  • Default response: A configured fallback value can replace channel data after the host loses the module.
  • Hold-last response: The alternative loss setting retains the most recent value instead of applying the default.
  • Stale-data flag: Application logic can use module status so a retained word is not treated as a new conversion.

Fifteen-Point Bipolar Voltage Groups

  • Conditioned sources: Up to fifteen –10 to +10 V devices can share one module position when their references are compatible.
  • Dense feedback: Drives, transducers and controllers can map their voltage outputs to individual host words.
  • Remote placement: VersaMax NIU operation locates the shared-return voltage group near its field wiring.
Description
Fifteen single-ended –10 to +10 V sources connect to the General Electric IC200ALG263 through individual signal terminals and the shared A17 return. Its 15-bit converter produces one signed input word per channel at a 7.5 ms module update rate.

A known internal stimulus lets General Electric IC200ALG263 verify the A/D path. Three consecutive unexpected results stop channel scanning, extinguish the OK LED and create an Internal Hardware fault rather than leaving doubtful values active.

Logic and frame isolation protects the complete input group of General Electric IC200ALG263, but the channels are not isolated from one another. Compatible source references, carrier-specific shield grounding and a chosen default-or-hold-last response are therefore part of the system design.
Revisions

Revision Part #

Also known as

IC200ALG263D
IC200ALG263-D, Series D, Rev D
IC200ALG263E
IC200ALG263-E, Series E, Rev E
IC200ALG263F
IC200ALG263-F, Series F, Rev F
IC200ALG263H
IC200ALG263-H, Series H, Rev H
IC200ALG263J
IC200ALG263-J, Series J, Rev J
Alternative Names
IC200-ALG263 IC200 ALG263 IC 200 ALG 263 GE IC200ALG263 GE Fanuc IC200ALG263 Emerson IC200ALG263 VersaMax IC200ALG263 Voltage Input 1C200ALG263
Technical notes
General Electric IC200ALG263 is a 15-channel, 15-bit single-ended ±10 V VersaMax input module with a shared common return. It supplies fifteen input words and updates the channel set in 7.5 ms.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why does General Electric IC200ALG263 stop updating and turn off its OK LED?
General Electric IC200ALG263 stops scanning after three consecutive unexpected A/D results. Power-cycle the station once after checking the carrier and wiring; if the condition returns, follow the manual's direction to replace the module.
Why do several General Electric IC200ALG263 channels shift when one field source is connected?
General Electric IC200ALG263 uses single-ended channels with one common return. Review source grounding and common wiring for circulating current or an unintended reference path, then reconnect shields using the documented method.
How should a controller behave if General Electric IC200ALG263 is removed or loses data?
The host configuration for General Electric IC200ALG263 can select a default value or hold the last value on module loss. Choose the response that places each process in a known safe state and make the application detect stale data.
Why is a General Electric IC200ALG263 reading pinned near the positive or negative limit?
General Electric IC200ALG263 converts only the documented bipolar voltage range. Measure the source against the shared return, check polarity and scaling, and verify that the input has not exceeded the module range.
Can General Electric IC200ALG263 accept field sources with unrelated grounds?
General Electric IC200ALG263 groups fifteen non-isolated, single-ended inputs around one common return. Sources with incompatible reference potentials require a wiring or signal-conditioning review rather than direct connection.
How can General Electric IC200ALG263 noise be reduced without hiding a wiring fault?
For General Electric IC200ALG263, first separate signal cable from high-energy conductors, check shield termination and stabilize the common reference. Apply controller filtering only after the physical wiring and source grounding are correct.

Product Browsing History