IC200UEC008

/ 4.9
1001 reviews | Need a Specific Revision?
General Electric IC200UEC008 is an 8-point VersaMax Micro expansion unit that adds four 24 VDC inputs and four protected sourcing transistor outputs to a compatible Micro PLC.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for IC200UEC008
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for IC200UEC008

  • Manufacturer:
    General Electric
  • Part Number:
    IC200UEC008
  • Product Family:
    GE VersaMax
  • Product Type:
    VersaMax Micro 8-Point Protected I/O Expansion Unit
  • Stock:
    1
  • Input Points:
    4
  • Input Type:
    24 VDC positive/negative logic
  • Output Points:
    4
  • Output Type:
    24 VDC sourcing transistor with ESCP
  • Module Supply:
    24 VDC nominal; -20%/+25%
  • Output Load:
    0.7 A per point; 3 A per common
  • Output Response:
    0.05 ms maximum
  • Input Response:
    4 ms typical
  • Auxiliary 24 VDC:
    200 mA maximum
  • Isolation:
    1500 V RMS field-to-logic; 500 V RMS between groups
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Integration Diagnostics Output Protection Cabling

Features:

  • Adds four configurable 24 VDC inputs and four sourcing transistor outputs.
  • Protects each output group with electronic short-circuit protection.
  • Links into a VersaMax Micro expansion chain located up to two meters away.
The module expands mixed discrete I/O without adding another CPU or network adapter.

Power, OK and individual point LEDs give technicians a local indication before they open programming software or test field wiring.

Removable terminal blocks and plug-in ribbon cables separate field connections from the expansion link, helping reduce rewiring during service.

The General Electric IC200UEC008 VersaMax Micro 8-Point Expansion Unit may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
General Electric IC200UEC008 VersaMax Micro Expansion Manuals, Datasheets, Links Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Expansion Chain Design

  • Controller Range: The unit works with compatible 14- through 64-point VersaMax Micro PLCs.
  • Unit Count: A Micro PLC accepts up to four expansion units in any supported combination.
  • Left Connector: The incoming cable attaches from the PLC or previous expansion unit.
  • Right Connector: The outgoing socket continues the chain to the next expansion module.

Local Status Indicators

  • Power LED: The local indicator confirms that module supply is present.
  • OK LED: Module status is reported independently of individual point states.
  • Input LEDs: Four indicators mirror the electrical state of the input circuits.
  • Output LEDs: Four indicators show commanded point activity for wiring checks.

Protected Source Circuits

  • Electronic Limit: ESCP responds to an output short without requiring a point fuse.
  • Load Polarity: Each transistor output sources current from the positive field supply.
  • Inrush Support: The circuit accommodates compatible lamp and capacitive starting currents.
  • Inductive Loads: Negative pulse protection assists when coils are switched off.

Approved Interconnect Options

  • Included Lead: Each unit is supplied with a 0.1 m IC200CBL501 ribbon cable.
  • Medium Lead: IC200CBL505 provides a 0.5 m expansion connection.
  • Long Lead: IC200CBL510 provides a 1 m expansion connection.
  • Total Distance: The installed cable combination must stay within the two-meter chain limit.
Description
General Electric IC200UEC008 expands a compatible VersaMax Micro PLC with four 24 VDC input points and four sourcing transistor outputs. It joins the controller or preceding expansion unit through the left connector, while the right connector continues the chain to another unit.

The input circuits accept positive- or negative-logic field wiring, so common groups can be matched to the sensor convention used in the machine. Point LEDs provide direct visibility of input and output states, while separate Power and OK indicators help distinguish local supply problems from field-signal conditions.

Each output sources current to the load and includes electronic short-circuit protection, removing the need for individual output fuses under the stated configuration. An external 12/24 VDC output supply is still required, and load current, common-group capacity and inductive switching behavior must remain within the unit limits.
Alternative Names
IC200UEC008 IC200-UEC008 GE IC200UEC008 IC200 UEC008 VersaMax Expansion IC200UEC008 IC200 UEC 008 GE Fanuc IC200UEC008 IC200UEC00B
Technical notes
General Electric IC200UEC008 is an 8-point VersaMax Micro expansion unit with four DC inputs and four ESCP-protected sourcing outputs. Use a compatible expansion cable and external 12/24 VDC output supply.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How do the indicators on General Electric IC200UEC008 help locate a missing field signal?
Power and OK indicators on General Electric IC200UEC008 separate supply or module problems from point-level conditions. Four input and four output LEDs then show whether the expected electrical state is reaching each circuit.
Which expansion cables can be used with General Electric IC200UEC008?
General Electric IC200UEC008 supports the approved IC200CBL501, IC200CBL505 and IC200CBL510 leads in 0.1, 0.5 and 1 m lengths. Keep the complete chain within the two-meter expansion limit.
When is General Electric IC200UEC008 preferable to a sinking-output expansion unit?
Choose General Electric IC200UEC008 when the field load needs a sourcing transistor output that supplies current from the positive side of the external DC circuit. Confirm load polarity before connecting the common and output conductors.
What protection responds if a General Electric IC200UEC008 output is shorted?
Electronic short-circuit protection is built into the sourcing outputs of General Electric IC200UEC008. Remove the fault and verify the load and wiring before restoring operation, while still observing point and common current limits.
How is General Electric IC200UEC008 inserted into an existing Micro PLC station?
Connect the left expansion socket of General Electric IC200UEC008 to the controller or preceding unit; use the right socket only when the chain continues. The PLC supports up to four compatible expansion units in total.
Can General Electric IC200UEC008 work with both PNP and NPN-style input wiring?
The four inputs on General Electric IC200UEC008 support positive- or negative-logic arrangements. Select the matching common connection for the installed sensors and verify the field voltage before attaching the removable terminal block.