Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail info@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power provides documentation, procurement support and system-matching guidance for General Electric IC200UDR001.

IC200UDR001

/ 4.9
1001 reviews | Need a Specific Revision?
General Electric IC200UDR001 is a 14-point VersaMax Micro PLC with eight 24 VDC inputs, six relay outputs and a 120/240 VAC power supply.
In Stock
Ships by Tuesday, September 29
Fast Shipping Available
Get a quick price for IC200UDR001
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for IC200UDR001

  • Manufacturer:
    General Electric
  • Part Number:
    IC200UDR001
  • Product Family:
    GE VersaMax
  • Product Type:
    14-Point AC-Powered VersaMax Micro PLC
  • Stock:
    1
  • Integrated I/O:
    8 inputs / 6 outputs
  • Input Type:
    24 VDC positive or negative logic
  • Output Type:
    Normally open Form A relay
  • Relay Rating:
    2 A at 24 VDC or 240 VAC
  • Controller Supply:
    120/240 VAC nominal
  • AC Input Range:
    85-264 VAC
  • Supply Frequency:
    47.5-63 Hz
  • Power Rating:
    13 VA
  • High-Speed Counters:
    Up to four Type A or one Type A plus one Type B
  • Counter Frequency:
    10 kHz maximum
  • Auxiliary 24 VDC Output:
    200 mA maximum
  • Serial Port:
    RS-232, RJ-45
  • Program Memory:
    9K words
  • Register Memory:
    256 words
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals AC Supply Relay Loads Input Logic Applications

Features:

  • Operates from 120/240 VAC while supplying 24 VDC for input devices.
  • Switches compatible AC or DC loads through six normally open relay contacts.
  • Combines configurable sensor inputs, flash storage and an RS-232 programming port.
The AC power section lets General Electric IC200UDR001 start from common mains sources across an 85-264 VAC operating range. Its 24 VDC auxiliary output supplies up to 200 mA for input circuits and eligible field devices.

Six isolated Form A contacts control externally powered loads from 5-30 VDC or 5-250 VAC. This arrangement separates the controller power source from the voltage switched by motor starters, solenoids or indicators.

Two removable screw-down barrier-style terminal strips with covers carry field wiring, while the front Run/Stop switch, two analog potentiometers and RS-232 RJ-45 port provide local operating and setup access.

The General Electric IC200UDR001 14-Point AC-Powered VersaMax Micro PLC may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
General Electric IC200UDR001 14-Point AC-Powered VersaMax Micro PLC Manuals,Datasheets,LinkImportant Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Mains Input Planning

  • Voltage window: Provide 85-264 VAC to cover the nominal 120/240 VAC controller supply.
  • Frequency window: Keep the source within 47.5-63 Hz so the AC power section remains in range.
  • Ride-through: Allow for 10 ms hold-up at 85-100 VAC and 20 ms from 100-264 VAC.
  • Inrush allowance: Size upstream protection for the stated peak current during the two-millisecond energization interval.

Form A Output Use

  • Contact arrangement: Each output is a normally open, single-pole single-throw relay contact.
  • Field source: Supply external AC or DC power to the controlled device; the contact does not source load power.
  • Load selection: Use compatible motor starters, solenoids or indicators within the relay ratings.
  • Waveform limit: Do not assign these mechanical contacts to PWM or pulse-train operation.

Sensor and Counter Connections

  • Polarity choice: Wire the 24 VDC inputs for the positive- or negative-logic scheme selected in configuration.
  • Common devices: Connect suitable pushbuttons, limit switches or proximity sensors as standard inputs.
  • Fast counting: Allocate up to four Type A counters or one Type A plus one Type B at frequencies to 10 kHz.
  • Input supply budget: Keep combined input-circuit and user-device current within the 200 mA auxiliary rating.

Compact AC-Powered Controls

  • Starter panels: Relay contacts interface PLC logic with compatible motor-starter control circuits.
  • Solenoid sequencing: Six independent outputs switch externally powered valves or actuators.
  • Machine sensing: Eight configurable DC inputs collect events from switches and proximity devices.
  • Pulse measurement: Built-in counters process moderate-speed signals for flow, velocity or material-handling tasks.
Description
Control panels supplied from AC mains can use the General Electric IC200UDR001 without a separate 24 VDC controller supply. Its input stage accepts eight 24 VDC signals, while six normally open Form A relays switch compatible AC or DC field loads.

Sensor interfaces on the General Electric IC200UDR001 may be configured for positive or negative logic. Pushbuttons, limit switches and electronic proximity devices can share the integrated 200 mA auxiliary 24 VDC source when their combined demand remains within its rating.

Relay contacts make the General Electric IC200UDR001 suitable for motor starters, solenoids and indicators that cannot be driven directly from a transistor output. The field-load circuit still needs its own AC or DC source, and counter-output assignments do not provide pulse-train or PWM modes.

Programming and retention facilities in the General Electric IC200UDR001 include Ladder Diagram or Instruction List logic, 9K words of application memory, 256 register words and non-volatile flash storage. A configurable Run/Stop switch and removable covered terminal strips support local setup and wiring service.
Alternative Names
IC200 UDR001 General Electric IC200UDR001 IC 200 UDR 001 GE Fanuc IC200UDR001 IC200-UDR001 IC2OOUDR001 VersaMax Micro IC200UDR001 GE IC200UDR001
Technical notes
General Electric IC200UDR001 combines an 85-264 VAC controller supply with eight 24 VDC inputs and six 2 A relay outputs for compact mixed-voltage panels.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
A replacement panel has only AC control power; can General Electric IC200UDR001 operate from it?
General Electric IC200UDR001 accepts a 120/240 VAC nominal supply within its stated 85-264 VAC range, while its integrated auxiliary source powers eligible 24 VDC input circuits and user devices up to 200 mA.
When a relay load chatters on General Electric IC200UDR001, which circuits should be separated during diagnosis?
Check the field-load source, contact wiring and coil or lamp inrush independently from the controller supply on General Electric IC200UDR001; each relay circuit switches an external AC or DC source.
How can mixed sensor polarities be accommodated by General Electric IC200UDR001?
Configure each supported input group and common so the field devices follow the chosen positive- or negative-logic arrangement for General Electric IC200UDR001, then verify the 24 VDC ON threshold.
What causes a counter application to fail when relay outputs of General Electric IC200UDR001 are treated like pulse-train channels?
Relay outputs on General Electric IC200UDR001 can serve documented counter-output functions but do not support PWM or pulse-train modes; choose the appropriate controller family variant when those waveforms are essential.
Why should terminal assignments be reviewed before swapping another 14-point PLC for General Electric IC200UDR001?
General Electric IC200UDR001 combines AC controller power, 24 VDC inputs and Form A relay outputs, so matching only the point count can overlook supply, common, contact and serial-port differences.
Which programming checks help recover a General Electric IC200UDR001 after application memory is lost?
On General Electric IC200UDR001, verify whether configuration and logic are set to load from flash at startup, then confirm the Run/Stop switch role and restore the intended Ladder Diagram or Instruction List project.

Product Browsing History