Features:
- Selectable 115/230 V AC input operates at 50/60 Hz with the 1.5/0.75 A current draw.
- The regulated output is rated 5 V DC at 15 A for compatible information-system chassis.
- The exact label identifies Hirschmann / VOGT electronic part number 711 20 106 10.
The supplied assembly is the AC-input R execution, dated 25 January 2005 and marked for information-systems use.
Its conversion stage rectifies the selected mains source and maintains the low-voltage rail required by the host electronics.
Match connector coding, chassis airflow, mains selector and 5 V load budget before substituting another ENT 10515 variant.
Apter Power can support exact-model configuration review and quotation for Hirschmann ENT 10515-R AC.
Verified resources for Hirschmann ENT 10515-R AC:
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Compatible legacy information-system racks can obtain a centralized 5 V supply for logic and interface assemblies.
- Service replacement can restore a failed power slot when the chassis connector and mechanical code match exactly.
- Bench verification can confirm regulated output and load capability before the module is returned to a critical host.
- The conversion stage supplies regulated low-voltage power to information-system loads from the selected AC input.
- Input current is 1.5 A at 115 V AC or 0.75 A at 230 V AC under the specified operating conditions.
- The regulated 5 V DC output can deliver up to 15 A when cooling, wiring and total load remain within the rating.
- IEC 950, EN 60950 and UL 1950 define the information-technology equipment safety basis for this supply.
- Correct mains selection, connector coding and protective-earth continuity must be confirmed before the unit is energized.
- The supply converts selectable 115 or 230 V AC input power into a regulated 5 V DC source rated at 15 A.
- Selectable 115 or 230 V AC input allows connection to the intended mains system when the selector and wiring agree.
- The 50/60 Hz frequency range supports standard industrial supplies within the marked input-voltage configuration.
- A regulated 5 V DC, 15 A output must be matched to the load connector, conductor size and cooling arrangement.