Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Discontinued / Obsolete by OEM
    Apter Power can assist with HE800DNM650 quotation requests and access to official Horner SmartStack metal documentation for installed systems.

HE800DNM650

/ 4.9
1001 reviews | Need a Specific Revision?
Horner HE800DNM650 is a SmartStack metal DeviceNet Master Communications Module for compatible Classic OCS, RCS, RX, and Metal FOX controller platforms.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for HE800DNM650
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for HE800DNM650

  • Manufacturer:
    HORNER
  • Part Number:
    HE800DNM650
  • Product Family:
    HORNER
  • Product Type:
    DeviceNet Master Communications Module
  • Stock:
    1
  • DeviceNet Services:
    Poll, bit-strobe, cyclic, change-of-state, Class 2 explicit
  • UCMM:
    Groups 1, 2, and 3 fragmented messages
  • DeviceNet Nodes:
    Up to 63 slaves
  • Maximum Baud Rate:
    500 kBaud
  • I/O Data per Slave:
    Up to 256 B input / 256 B output
  • Configuration:
    RS232 serial port; Cbreeze or Cscape
  • Operating Temperature:
    0–55 °C
  • Relative Humidity:
    5–95%, non-condensing
  • Tariff Code:
    8538900000
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Compatibility DeviceNet Configuration Applications

Features:

  • DeviceNet master interface for SmartStack metal controller systems
  • Support for up to 63 DeviceNet slaves
  • Up to 256 bytes of input and output data per slave
The listed SmartStack metal configuration adds the Horner HE800DNM650 DeviceNet master interface to compatible Classic OCS, RCS, RX, and Metal FOX controller platforms.

DeviceNet operation supports poll, bit-strobe, cyclic, change-of-state, and Class 2 explicit messaging, with UCMM capability through Groups 1, 2, and 3 fragmented messages.

Confirm controller compatibility, the metal SmartStack I/O arrangement, DeviceNet wiring, and the required communication method before installation.

Apter Power assists with pricing and access to official manufacturer documentation for Horner HE800DNM650 DeviceNet Master Communications Module.
Horner HE800DNM650 DeviceNet Master Communications Module Manuals, Datasheets, Links Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Platform fit: Horner lists HE800DNM650 for compatible Classic OCS, RCS, RX, and Metal FOX controller platforms.
  • Stack arrangement: Confirm the installed system uses the metal SmartStack I/O arrangement before selecting the module.
  • Integration review: Match the controller platform and intended DeviceNet role before installation.
  • Network exchange: Select poll, bit-strobe, cyclic, change-of-state, or Class 2 explicit messaging according to the DeviceNet devices in the system.
  • Message handling: UCMM capability supports Groups 1, 2, and 3 fragmented messages when the application requires those services.
  • Network planning: Allow for up to 63 DeviceNet slaves when defining the system node layout.
  • Commissioning path: Configure the module through the RS232 serial port or with Cbreeze or Cscape software.
  • Network setup: Confirm the selected DeviceNet service and connected slave devices before startup.
  • Data planning: Each slave can use up to 256 bytes of input data and 256 bytes of output data, so map the required data before commissioning.
  • Controller extension: Use the module when a compatible metal SmartStack controller requires a dedicated DeviceNet master interface.
  • Distributed I/O planning: The module can coordinate communication with up to 63 DeviceNet slaves in a controller-based system.
  • Installation preparation: Verify the controller platform, 5-pin DeviceNet connection, and selected communication method before installation.
Description
Designed for compatible Classic OCS, RCS, RX, and Metal FOX controller platforms using metal SmartStack I/O, the Horner HE800DNM650 provides a dedicated DeviceNet master interface for controller systems that require DeviceNet communication.

For network operation, the Horner HE800DNM650 supports poll, bit-strobe, cyclic, change-of-state, and Class 2 explicit messaging, with UCMM capability through Groups 1, 2, and 3 fragmented messages. It supports up to 63 DeviceNet slaves and provides up to 256 bytes of input data and 256 bytes of output data for each slave.

During commissioning, the Horner HE800DNM650 uses a 5-pin screw terminal for DeviceNet connection and supports a maximum baud rate of 500 kBaud. Configuration is available through the RS232 serial port or with Cbreeze or Cscape software; confirm controller compatibility, wiring, and the selected communication method before startup.
Alternative Names
HE800-DNM650 HE800 DNM650 HE800DNM 650 Horner HE800DNM650 Horner APG HE800DNM650 DNM650 HORNER-HE800DNM650 Horner HE800-DNM650
Technical notes
For system expansion, review the installed controller’s metal SmartStack I/O arrangement before selecting Horner HE800DNM650. Plan the required DeviceNet data exchange before commissioning.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How does the Horner HE800DNM650 fit into an existing controller system?
Before installation, compare the controller with the supported Classic OCS, RCS, RX, or Metal FOX platforms and confirm that the installed I/O is the metal SmartStack type. The Horner HE800DNM650 then provides the DeviceNet master interface for that arrangement.
Which DeviceNet communication methods can the Horner HE800DNM650 use?
Choose the messaging method to suit the connected DeviceNet devices: poll, bit-strobe, cyclic, change-of-state, or Class 2 explicit. Where UCMM is required, the Horner HE800DNM650 supports Groups 1, 2, and 3 fragmented messages.
How can I plan DeviceNet node capacity with the Horner HE800DNM650?
Plan node count and data mapping together. A Horner HE800DNM650 can support up to 63 DeviceNet slaves, with up to 256 bytes of input and 256 bytes of output data per slave.
What connection should I prepare for the Horner HE800DNM650?
Prepare the DeviceNet cable and the module’s 5-pin screw-terminal connection, then verify the pin assignment against the applicable documentation. Inspect cable condition before connecting the Horner HE800DNM650 to the network.
How is the Horner HE800DNM650 configured during commissioning?
Commission the module from the RS232 serial port or use Cbreeze or Cscape software. Before startup, align the Horner HE800DNM650 settings with the intended nodes and messaging service.
What site conditions should be checked before installing the Horner HE800DNM650?
Check the enclosure and installation conditions first: 0–55 °C and 5–95% non-condensing relative humidity. Keeping the Horner HE800DNM650 within these stated limits supports suitable installation planning.