Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Discontinued / Obsolete by OEM
    Apter Power maintains a reliable inventory of legacy Honeywell CC-GDIL01 digital input module, providing industrial facilities with dependable replacement parts to support ongoing maintenance and prevent unexpected line downtime.

CC-GDIL01 51306317-175

/ 4.9
1001 reviews | Need a Specific Revision?
The Honeywell CC-GDIL01 51306317-175 is an advanced 32-channel high-density Series C digital input expansion termination assembly engineered to provide stable, uninterrupted hardware routing and double-power bus redundancy for high-availability distributed control systems.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for CC-GDIL01 51306317-175
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for CC-GDIL01 51306317-175

  • Manufacturer:
    Honeywell
  • Part Number:
    CC-GDIL01 51306317-175
  • Product Family:
    Honeywell Experion PKS ( C200, C300 )
  • Product Type:
    Digital Input High-Density Redundant Expansion
  • Stock:
    1
  • Input Channels:
    32 Channels
  • Physical Dimensions:
    12-inch Nom. Width (304 mm) Series C Footprint
  • Galvanic Isolation:
    1500 VAC RMS or ±1500 VDC (Executed via Plugged IOM)
  • Isolation Technique:
    Optical Isolation (Embedded in mating I/O Module)
  • DI Power Range:
    18 to 30 VDC
  • ON State Threshold:
    13 VDC minimum / 3 mA minimum
  • OFF State Threshold:
    5 VDC maximum / 1.2 mA maximum
  • Input Impedance:
    4.2 KΩ
  • Absolute Delay:
    5 ms ± 20% across input filter and isolation
  • Cabinet External Temperature:
    0°C to 50°C (32°F to 122°F) Operative Ambient Limits
  • Cabinet Internal Air Temperature:
    0°C to 60°C (32°F to 140°F) Maximum Inside Enclosure Air
  • Storage Temperature:
    -40°C to 85°C (-40°F to 185°F)
  • Relative Humidity:
    5% to 95% Non-Condensing (Strict Platform Rating)
  • Weight:
    0.46 kg
  • Estimated shipping dimensions:
    29.5x24x5.5cm
  • Tariff Code:
    8538900000
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Applications Monitoring & Control Performance & Efficiency

Features:

  • High-Density Redundant Power Bus Routing
  • Transferred 1500V Optical Isolation Defense
  • Support for Proactive Open-Wire
The Honeywell CC-GDIL01 51306317-175 utilizes a ruggedized 12-inch chassis footprint layout capable of channeling 32 distinct digital input loops safely while directly interlocking with the integrated Series C redundant power bus to completely eliminate single-point control failure liabilities.

Engineered to pass data seamlessly to companion modules, the Honeywell CC-GDIL01 51306317-175 architecture utilizes high-level 1500 VAC RMS or ±1500 VDC optical isolation techniques to prevent ground loops and high-voltage spikes from propagating into critical backplane controllers.

DiagnosticsDesigned to optimize loop transparency, the Honeywell CC-GDIL01 51306317-175 fully maps and routes real-time line monitoring signals, ensuring the host controller immediately marks compromised field cables with an "invalid" PV status before bad data induces false plant-wide tripping.

The CC-GDIL01 51306317-175 Honeywell Digital Input High-Density Redundant Expansion may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Honeywell CC-GDIL01 51306317-175 Digital Input High-Density Redundant Expansion Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Honeywell CC-GDIL01 51306317-175 Digital Input High-Density Redundant Expansion

General

  • Manufacturer Honeywell
  • Model CC-GDIL01 51306317-175
  • Condition New Original ready stock
  • Product Family CC-TCF901 51308301-175,CC-PCNT01 51405046-175,CC-PDOB01 51405043-175
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Deployed inside upstream oil and gas production hubs to safely collect discrete process metrics across standard, clean industrial control room environments.
  • Utilized across heavy chemical processing assets to cleanly route multi-channel safety interlocks and critical valve position limit feedbacks.
  • Integrated into power generation turbine control layouts to efficiently link high-speed Sequence of Events (SOE) tracking loops to central controllers.
  • Embedded within offshore platforms where high vertical packing density, zero footprint waste, and rigid structural reliability are operational imperatives.
  • Delivers organized, clean physical termination routing for up to 32 independent digital input field signal streams.
  • Accommodates advanced line-monitoring pathways to accurately pass diagnostic cable-break indicators straight to the supervisor interface.
  • Relays critical board connection and component health status tags directly back to the host system data blocks for real-time visualization.
  • Provides highly stable terminal wiring continuity to safeguard loop fidelity under highly fluctuating ambient or electromagnetic load conditions.
  • Decreases unscheduled plant shutdowns via immediate loop fault notification and systemic bad PV suppression safeguards.
  • Automatically benefits from tilted hardware styling that increases vertical cabinet dissipation efficiency, allowing the 32-channel layout to maintain strict 60°C internal enclosure compliance.
  • Lowers ongoing operational and maintenance labor costs by facilitating straightforward module replacement without touching underlying field terminations.
  • Boosts discrete monitoring uptime and system bandwidth to keep processing assets executing at optimized commercial capacity.
Description
The Honeywell CC-GDIL01 51306317-175 represents a premier, field-proven Input Output Termination Assembly (IOTA) purpose-built for the Honeywell Experion PKS Series C architecture. Acting as a dedicated high-density redundant expansion platform, this hardware provides the robust mechanical and electrical infrastructure necessary to bridge demanding plant floor operations with centralized automation system controllers. Its innovative, compact form factor minimizes total footprint while shielding critical communication trunks from devastating industrial noise.

Engineered to operate seamlessly alongside high-density 24VDC digital input cards, the Honeywell CC-GDIL01 51306317-175 facilitates uncompromised discrete data acquisition. While field wiring terminates directly onto the heavy-duty detachable terminal blocks of this IOTA, the host system relies on the plugged-in input modules' optical circuits to execute 1500 VAC RMS galvanic isolation. This layered architecture effectively isolates field anomalies and ground loops, optimizing signal integrity across complex process loops.

By utilizing an intelligent 12-inch profile layout, the Honeywell CC-GDIL01 51306317-175 satisfaction-guarantees plant continuity by utilizing dual-power bus integration that eliminates single points of failure. It serves as a passive routing network that seamlessly delivers advanced channel-level diagnostics, such as real-time open-wire detection, directly to host controllers when populated with diagnostics-capable IOMs. This lets operators mitigate unpredicted process trips and streamline preventative loop maintenance.
Alternative Names
CC-GDIL01 CC-GDILO1 51306317-175 CC-GD1L01 51306317-175 CC-GDIL0I 51306317-175 CC-GDIL01-51306317-175 CC-TCF901 51308301-175 CC-PCNT01 51405046-175 CC-PDOB01 51405043-175
Technical notes
The Honeywell CC-GDIL01 51306317-175 requires rigid mounting onto authorized Series C power carriers and must be physically secured to the system busbar to establish redundant 24VDC power routing. Plant technicians must verify field wire routing conforms to local loop-resistance guidelines to ensure proper functionality of module-driven open-wire check algorithms.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which controller modules and input cards are compatible with the Honeywell CC-GDIL01 51306317-175?
The Honeywell CC-GDIL01 51306317-175 is engineered exclusively for the Experion PKS Series C platform, interfacing directly with C300 controllers via 32-channel high-density modules including the standard CC-PDIL01 input module and the CC-PDIS01 Sequence of Events (SOE) module.
How does the Honeywell CC-GDIL01 51306317-175 handle field signal isolation and prevent electrical noise?
The loop containing the Honeywell CC-GDIL01 51306317-175 delivers 1500 VAC RMS or ±1500 VDC galvanic isolation by bridging field inputs with the plugged module's internal optical isolation components, entirely blocking common-mode noise and ground loops.
What diagnostic capabilities are supported through the Honeywell CC-GDIL01 51306317-175 hardware framework?
The Honeywell CC-GDIL01 51306317-175 fully routes line-monitoring communication, enabling advanced open-wire bad PV detection to force an "invalid" status flag in the control logic whenever field cable degradation is sensed.
How are parameter numbers and part configurations structured for the Honeywell CC-GDIL01 51306317-175 in engineering software?
Inside Honeywell Experion Control Builder, the Honeywell CC-GDIL01 51306317-175 is mapped via its unique hardware profile assignment string, linking the 32-channel high-density redundant slot allocation directly to the corresponding IOM driver database.
What physical installation steps are required when mounting the Honeywell CC-GDIL01 51306317-175 in a Series C cabinet?
Installing the Honeywell CC-GDIL01 51306317-175 requires securing the 12-inch IOTA board onto the bussed carrier channel using specialized board screws, verifying grounding-rail connection, and firmly snapping the mating digital input card onto the termination seat.

Product Browsing History