Features:
- One-meter carrier channel for Series C IOTA mounting
- Integrated 24 V DC and common-ground bus bars
- Dedicated shield-landing bus for field wiring
CC-MCAR01 is the channel assembly used to mount Series C input output terminal assemblies in an Experion PKS cabinet. Honeywell describes the carrier as approximately one meter or three feet long.
The assembly organizes the IOTA mounting supports together with a 24 V DC bus, a common and ground bus, and a field-wiring shield landing bar. This construction distributes cabinet services along the channel.
Before installing CC-MCAR01, confirm the cabinet width, rail support, number and spacing of IOTAs, power-feed arrangement, grounding scheme and field-cable routing. The carrier should be matched to the complete Series C mechanical layout.
The Honeywell CC-MCAR01 IOTA Carrier Channel Assembly is available for cabinet-layout review, quotation and sourcing support from Apter Power.
Honeywell CC-MCAR01 IOTA Carrier Channel Assembly Manuals, Datasheets, Links
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Honeywell CC-MCAR01 IOTA Carrier Channel Assembly Specs
General
- ManufacturerHoneywell
- ModelCC-MCAR01
- ConditionNew Original ready stock
- Product FamilyHoneywell Experion PKS ( C200, C300 )
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Carrier arrangement
- Channel length: The assembly is documented as one meter or three feet long.
- IOTA supports: Series C IOTAs mount along the carrier channel structure.
- Cabinet layout: Spacing must allow IOTA access and field-wire routing.
- Mechanical check: Confirm supports and available enclosure width before installation.
Integrated distribution bars
- Power bus: A 24 V DC bus runs along the channel.
- Common bus: The assembly includes 24 V DC common and grounding provision.
- Shield landing: A separate bus accepts field-cable shields.
- Continuity: Ground and shield bonding must follow the cabinet engineering drawings.
Cabinet integration review
- IOTA count: Determine the quantity and order of mounted IOTAs.
- Power feed: Size and connect the 24 V DC source for the installed hardware.
- Cable routing: Maintain access for field terminals and shield conductors.