  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Discontinued / Obsolete by OEM
    Apter Power specializes in distributing certified, surplus Honeywell FC-TCNT11 modules, providing critical process facilities with an essential backup supply line for obsolete ESD safety components.

FC-TCNT11

/ 4.9
1001 reviews | Need a Specific Revision?
The FC-TCNT11 is a Honeywell redundant IOTA controller module for SC S300 Safety Manager systems, enabling seamless failover between primary and backup controllers for SIL3 safety applications.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for FC-TCNT11
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for FC-TCNT11

  • Manufacturer:
    Honeywell
  • Part Number:
    FC-TCNT11
  • Product Family:
    Honeywell Safety Systems
  • Product Type:
    Controller Module
  • Stock:
    1
  • Input Power:
    24V DC nominal
  • Power Consumption:
    40 W
  • Operating Temperature:
    -20°C to +70°C
  • Certifications:
    CE, UL, TÜV
  • Storage Temperature:
    -40°C to +85°C
  • Maximum Output Current:
    2 A
  • Number of I/O Points/Channels:
    32 channels
  • Accuracy:
    ±0.05% full scale
  • Analog Output:
    4-20mA standard
  • Weight:
    0.45 kg
  • Estimated shipping dimensions:
    36.8x12x5cm
  • Tariff Code:
    8517795000
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Application Communication Safety and Compliance

Features:

  • Provides seamless, bumpless switchover between primary and backup controllers with real-time memory, I/O, and logic state synchronization; zero data loss during transitions
  • TÜV-certified for IEC 61508 SIL3 safety integrity level; suitable for Emergency Shutdown (ESD), Fire & Gas (F&G), and Burner Management Systems (BMS)
  • Supports online replacement without system shutdown; built-in advanced diagnostics monitor module health, communication status, and fault conditions for proactive maintenance
The FC-TCNT11 is engineered for high-availability safety systems where controller failure cannot be tolerated. It enables dual redundant configurations where a primary and backup controller operate in synchrony. The module continuously monitors the health of both controllers and manages automatic failover. When the primary controller fails, the backup takes over instantaneously (bumpless switchover) without any interruption to the safety logic execution. Real-time synchronization ensures that memory contents, I/O states, and logic execution are perfectly aligned between the two controllers at all times.

The FC-TCNT11 is TÜV-certified for IEC 61508 Safety Integrity Level 3 (SIL3), the highest rating for industrial safety systems. This certification confirms that the module meets stringent requirements for systematic capability, architectural constraints, and random failure mitigation. Safety Instrumented Systems (SIS) built with FC-TCNT11 modules can claim SIL3 capability for entire safety loops. Typical applications include Emergency Shutdown (ESD) systems that isolate hazardous processes, Fire & Gas (F&G) detection systems that trigger alarms and suppression, and Burner Management Systems (BMS) that control boiler startups and shutdowns.

The FC-TCNT11 is designed for maintainability in 24/7 operations. Its hot-swappable construction allows a technician to remove and replace a module without powering down the system or interrupting safety functions. This is crucial in continuous processes where shutdowns are prohibitively expensive (e.g., ethylene crackers, LNG plants). The module also features comprehensive onboard diagnostics: status LEDs indicate power, communication activity, network health, and fault conditions. Advanced diagnostics continuously verify critical functions including memory integrity, communication link status, and internal voltage rails.

The FC-TCNT11 Honeywell Controller Module may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL)by the manufacturer (OEM).

Honeywell FC-TCNT11 Controller Module Manuals, Datasheets,Drivers,Link Important Notice:Other accessories,manuals,cables,calibration data,software,etc.are not included with this equipment unless listed in the above stock item description.All prices are shown in USD.
Honeywell FC-TCNT11 Controller Module Specs

General

  • Manufacturer Honeywell
  • Model FC-TCNT11
  • Condition New Original ready stock
  • Product Family FC-SCNT02,FC-TSRO-0824,FC-PSU-UNI2450U
Important Notice:Other accessories,manuals,cables,calibration data,software,etc.are not included with this equipment unless listed in the above stock item description.All prices are shown in USD.
  • Emergency Shutdown System (ESD): Ensures safe shutdown of factory equipment in the event of a hazardous situation.
  • Flame and Gas Monitoring System (F&G): Monitors for hazardous gas leaks or fires, triggering alarms and fire suppression interlocks.
  • Boiler Management System (BMS): Controls the ignition and operational safety of boilers or heaters.
  • Dual-Channel Redundancy Architecture: Provides dual communication paths. If the primary channel fails, the system immediately and seamlessly switches to the backup channel, ensuring uninterrupted control logic.
  • Network Connectivity: Communication ports directly connect to sensors, actuators, and other field devices.
  • System Integration: Seamless integration is possible through the Honeywell Experion PKS or Safety Builder platforms, supporting large-scale plant-wide communication.
  • Functional Safety Certification: TÜV certified, compliant with IEC 61508 / IEC 61511 standards, supporting applications up to SIL 3 (Safety Integrity Level 3).
  • ISASecure Certification: Compliant with ISASecure Level 1 and 2 certifications, ensuring device security throughout the development lifecycle, embedded functions, and communication robustness.
  • Communication Security: Supports IPsec encrypted communication, ensuring data security and integrity during data transmission.
Description
The FC-TCNT11 (part number 51307928-176) is a redundant IOTA (Input/Output Terminal Assembly) controller module engineered for Honeywell’s SC S300 Safety Manager and Experion PKS platforms. It serves as a critical communication bridge between redundant controllers and field I/O modules in Safety Instrumented Systems (SIS). 

When using the FC-TCNT11, engineers benefit from automatic, seamless failover between primary and backup controllers. The module maintains real-time memory, I/O, and logic state alignment across dual communication paths, ensuring zero data loss during redundancy transitions. Hot-swappable design allows replacement without system shutdown, significantly reducing maintenance downtime in critical processes. 

The FC-TCNT11 operates on 24V DC power and is designed for harsh industrial environments with an operating temperature range of -20°C to +70°C. For legacy Honeywell safety system expansions or repairs, the FC-TCNT11 provides a robust redundant controller solution. It seamlessly integrates with Honeywell Experion PKS and Safety Builder platforms. 
Alternative Names
FC-SCNT02 FC-TSRO-0824 FC-PSU-UNI2450U FC-TCNTII FCTCNT11 FC-TPSU-2430 FC-TSDI-1624
Technical notes
The FC-TCNT11 is a redundant IOTA (Input/Output Terminal Assembly) controller module, not a standalone processor. It works in conjunction with SC S300 processor modules to provide fault-tolerant controller redundancy for safety applications.The module features dual communication paths with automatic failover.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What redundancy feature does the FC-TCNT11 provide?
The FC-TCNT11 provides automatic, seamless failover between primary and backup controllers. If the primary fails, the backup takes over without any interruption. It maintains real-time synchronization of memory, I/O, and logic states, ensuring zero data loss during transition.
Is the FC-TCNT11 certified for safety applications?
Yes. The FC-TCNT11 is TÜV-certified for IEC 61508 SIL3 applications. It is designed for use in Safety Instrumented Systems (SIS) including Emergency Shutdown (ESD), Fire & Gas (F&G), and Burner Management Systems (BMS).
Can the FC-TCNT11 be replaced while the system is running?
Yes. The FC-TCNT11 supports hot-swapping, allowing replacement without system shutdown. This feature minimizes downtime during maintenance and ensures continuous operation of safety-critical processes.
Which Honeywell systems is the FC-TCNT11 compatible with?
The FC-TCNT11 integrates seamlessly with Honeywell Experion PKS, Safety Builder, and SC S300 Safety Manager platforms. It is specifically engineered for Honeywell’s Safety Instrumented System (SIS) architecture.