    Apter Power supports quotations, technical documentation and HPM pulse-input configuration review for MU-TPIX12 51304084-100.

MU-TPIX12 51304084-100

/ 4.9
1001 reviews | Need a Specific Revision?
Honeywell MU-TPIX12 51304084-100 is a nonconformally coated non-CE 8-channel pulse input FTA with compression terminals.
In Stock
Ships by Saturday, November 14
Fast Shipping Available
Get a quick price for MU-TPIX12 51304084-100
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for MU-TPIX12 51304084-100

  • Manufacturer:
    Honeywell
  • Part Number:
    MU-TPIX12 51304084-100
  • Product Family:
    Honeywell TDC 3000
  • Product Type:
    8-Channel Pulse Input Field Termination Assembly
  • Stock:
    1
  • Input type:
    Pulse input
  • Channels:
    8
  • Terminal type:
    Compression
  • Mounting size:
    B
  • Assembly current:
    136 mA at 24 Vdc
  • Coating:
    Nonconformal
  • Compliance version:
    Non-CE
  • Weight:
    0.72 kg
  • Estimated shipping dimensions:
    30.7x12x6.8cm
  • Tariff Code:
    8537109090
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Pulse Acquisition Hazardous-Area Use Cabinet Integration Product Applications

Features:

  • Eight-channel HPM pulse-input FTA
  • Compression terminals in a B-size format
  • Non-CE nonconformal material-number configuration
The FTA terminates pulse-input field signals for the HPM I/O architecture.

Its 136 mA assembly current contributes to cabinet 24 Vdc power demand.

The exact -100 material suffix distinguishes the non-CE assembly from the -125 CE variant.

Apter Power supports Honeywell MU-TPIX12 51304084-100 8-Channel Pulse Input Field Termination Assembly with technical documents, quotations and application review.
Honeywell MU-TPIX12 51304084-100 8-Channel Pulse Input Field Termination Assembly Manuals,Datasheets,Link Important Notice: Confirm the complete model, hardware revision and installed-system arrangement before use.
  • Eight-point intake: One FTA terminates eight field pulse signals for the HPM pulse-input processing path.
  • Counting continuity: Compression terminals provide the documented field interface for meter, counter or speed-pulse wiring already specified for the HPM channel design.
  • Cabinet demand: The 136 mA assembly current is included in the shared 24 Vdc load so pulse acquisition remains stable with the other I/O assemblies online.
  • Signal discipline: Shielding, grounding and pulse-level conditions follow the HPM channel design so counter noise is not mistaken for process events.
  • Division 2 scope: Honeywell lists MU-TPIX12 among the HPM assemblies approved for Division 2 installations.
  • Nonincendive circuits: Pulse-input wiring is covered only when the complete field circuit follows Honeywell's published nonincendive conditions.
  • Normal-operation basis: The nonincendive statement depends on the HPM remaining in its documented operating state and does not generalize to arbitrary wiring.
  • Field-circuit boundary: Compression-terminal wiring, approved field devices and the documented cabinet environment must remain inside the published installation basis.
  • B-size allocation: The pulse-input FTA occupies the standard B-size mounting position in the HPM cabinet.
  • Power coordination: Its 136 mA demand is added to the cabinet 24 Vdc load together with the connected pulse-input processor.
  • Terminal schedule: Channel assignment follows the installed HPM pulse-input drawings, preventing meter pulses from being landed on an adjacent input path.
  • Noise control: Pulse conductors are routed apart from switching outputs and other interference sources where the cabinet design requires separation.
  • Meter pulse collection: Bring pulse-output flow or production totalizers into an eight-point HPM pulse-input station.
  • Rotating-equipment counting: Terminate tachometer or speed-pickup pulse trains already engineered for the HPM pulse-input path.
  • Batch event accumulation: Collect discrete pulse counts from counters or dosing equipment through one B-size FTA.
  • Hazardous-area acquisition: Maintain approved Division 2 and nonincendive pulse circuits when the complete HPM wiring basis is preserved.
Description
Pulse and frequency signals enter the HPM through Honeywell MU-TPIX12 51304084-100, an eight-channel nonconformal FTA for the non-CE configuration.

Compression terminals and a B-size footprint define the field side of MU-TPIX12 51304084-100, while its 136 mA assembly demand becomes part of the cabinet 24 Vdc power calculation.

Division 2 and nonincendive listings give MU-TPIX12 51304084-100 a documented hazardous-location context when the complete HPM wiring and environmental conditions are retained.
Alternative Names
MU-TPIX12 51304084-100 MU TPIX12 51304084100 Honeywell MU-TPIX12 MU-TPIX12 pulse input FTA HPM MU-TPIX12 MU TPIX12 51304084 100
Technical notes
MU-TPIX12 51304084-100 is the non-CE pulse-input version; the related -125 material number is the CE configuration. The suffix therefore represents a compliance boundary rather than a cosmetic numbering change, and it should remain aligned with the cabinet approval basis.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Can MU-TPIX12 51304084-100 be fitted where the cabinet documentation calls for the CE -125 pulse-input assembly?
No. Honeywell defines the -100 configuration as non-CE, so using it in a position specified for the -125 CE version would change the cabinet compliance basis.
If existing field wires land on fixed screw terminals, is MU-TPIX12 51304084-100 the correct pulse-input FTA?
No. This model uses compression terminals; a fixed-screw installation points to the related TPIX52 form and should not be treated as the same field interface.
What supply margin should be reserved before adding MU-TPIX12 51304084-100 to an HPM cabinet?
Include the documented 136 mA assembly demand together with the pulse-input processor, other FTAs and shared cabinet loads. That total determines whether the existing 24 Vdc source has enough capacity.
What installation space must be available for MU-TPIX12 51304084-100?
The cabinet must provide the Honeywell B-size FTA position and the compression-terminal wiring access. A different footprint or terminal style is a stop signal for the installation.
When may MU-TPIX12 51304084-100 be used in a Division 2 or nonincendive circuit?
Only when the complete HPM cabinet, field wiring and environmental conditions follow Honeywell's published hazardous-location arrangement. The part number alone does not establish the approval.