  • Lifecycle status

    Active / Available from OEM
    Apter Power supports quotations, technical documentation and LLMux configuration review for MU-TLPA02 51309204-125.

MU-TLPA02 51309204-125

/ 4.9
1001 reviews | Need a Specific Revision?
Honeywell MU-TLPA02 51309204-125 is a CE-compliant two-unit power adapter for HPM low-level analog input multiplexer assemblies.
In Stock
Ships by Saturday, November 14
Fast Shipping Available
Get a quick price for MU-TLPA02 51309204-125
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for MU-TLPA02 51309204-125

  • Manufacturer:
    Honeywell
  • Part Number:
    MU-TLPA02 51309204-125
  • Product Family:
    Honeywell TDC 3000
  • Product Type:
    Low-Level Multiplexer Power Adapter
  • Stock:
    1
  • System role:
    LLMux power adapter
  • Connected FTA units:
    2
  • LLMux channel capacity:
    32 total with two 16-channel FTAs
  • Compatible IOP:
    MU-PLAM02
  • Assembly current:
    360 mA at 24 Vdc
  • Compliance version:
    CE compliant
  • Family boundary:
    LLMux only; not RHMUX
  • Weight:
    0.3 kg
  • Estimated shipping dimensions:
    15.1x12x5cm
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals LLMux Pairing Sensor Bank Design CE Signal Path Product Applications

Features:

  • Two-unit HPM LLMux power adapter
  • Supports RTD and thermocouple LLMux FTA combinations
  • CE-compliant material number for the nonconformal version
The adapter sits between the MU-PLAM02 LLMux IOP and two low-level analog FTAs.

Two sixteen-channel FTAs create the thirty-two-point LLMux input arrangement.

The architecture remains inside the LLMux family and does not extend to RHMUX assemblies.

Apter Power supports Honeywell MU-TLPA02 51309204-125 Low-Level Multiplexer Power Adapter with technical documents, quotations and application review.
Honeywell MU-TLPA02 51309204-125 Low-Level Multiplexer Power Adapter Manuals,Datasheets,Link Important Notice: Confirm the complete model, hardware revision and installed-system arrangement before use.
  • Architecture boundary: MU-TLPA02 belongs to the LLMux chain with MU-PLAM02 and is not compatible with the separate RHMUX architecture.
  • Two-FTA arrangement: One adapter connects two sixteen-channel LLMux FTAs, creating the documented thirty-two-point input assembly.
  • Mixed sensor banks: The two connected FTAs may be the same type or a combination of RTD and thermocouple assemblies.
  • Power allocation: The adapter contributes 360 mA to the 24 Vdc cabinet calculation before the remaining LLMux assemblies are added.
  • RTD bank: MU-TAMR03 accepts resistance-temperature inputs for one sixteen-channel LLMux section.
  • Local-reference thermocouples: MU-TAMT03 supports thermocouple inputs with its local cold-junction reference arrangement.
  • Remote-reference thermocouples: MU-TAMT13 supports a remote CJR when the reference junction must be located away from the FTA.
  • Flexible pairing: RTD and thermocouple banks can share the adapter, allowing one HPM LLMux point set to serve two temperature-measurement strategies.
  • Approved card file: CE use depends on the compliant card-file configuration rather than the adapter material number alone.
  • IOP connection: MU-KFTAxx serves the documented internal cable route, while MU-KFTSxx is used for the external IOP-to-FTA route.
  • FTA distance: Honeywell documents an external adapter-to-FTA path up to 305 m when the specified cable family is used.
  • CJR location: The remote-CJR thermocouple arrangement supports a reference-junction location up to 50 m from its FTA with the approved cabling.
  • Mixed temperature units: Combine an RTD FTA and a thermocouple FTA on one HPM LLMux adapter for a thirty-two-point process-temperature station.
  • Distributed thermocouple measurement: Use MU-TAMT13 when the cold-junction reference must be located remotely from the cabinet FTA.
  • Dense RTD monitoring: Connect two MU-TAMR03 banks for multi-point vessel, reactor or heat-exchanger temperature acquisition.
  • Long-distance temperature banks: Use the approved external LLMux cable path for remote sensor banks located away from the HPM cabinet.
Description
Two low-level analog FTAs share one Honeywell MU-TLPA02 51309204-125 power adapter on the way to an HPM LLMux I/O processor.

With MU-TLPA02 51309204-125 between the FTAs and MU-PLAM02, a pair of sixteen-channel RTD or thermocouple assemblies creates the thirty-two-point LLMux arrangement; the two FTAs may be the same type or different types.

CE operation gives MU-TLPA02 51309204-125 a wider architectural role than power alone because the compliant card file and the applicable MU-KFTAxx internal or MU-KFTSxx external cable complete the approved connection path.
Alternative Names
MU-TLPA02 51309204-125 MU TLPA02 51309204125 Honeywell MU-TLPA02 MU-TLPA02 LLMux power adapter HPM MU-TLPA02 MU TLPA02 51309204 125
Technical notes
MU-TLPA02 51309204-125 belongs only to the Honeywell LLMux architecture; Honeywell explicitly excludes RHMUX compatibility. A valid CE arrangement also uses the approved card file and either an MU-KFTAxx internal or MU-KFTSxx external IOP-to-FTA cable, according to the installation layout.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Can a temperature retrofit combine an RTD bank and a thermocouple bank on one MU-TLPA02 51309204-125?
Yes. One adapter can serve two supported sixteen-channel LLMux FTAs, and Honeywell allows the pair to use different RTD and thermocouple FTA types.
Which cable route should a CE cabinet designer choose for MU-TLPA02 51309204-125?
Use the MU-KFTAxx family for the documented internal route and MU-KFTSxx for the documented external route. The compliant card file remains part of the CE arrangement.
Should MU-TLPA02 51309204-125 be selected for an RHMUX modernization project?
No. Honeywell assigns this adapter to the LLMux architecture with MU-PLAM02 and keeps RHMUX as a separate system, so an RHMUX project needs its own approved hardware path.
How many low-level points can be planned when two supported FTAs are connected through MU-TLPA02 51309204-125?
The documented arrangement provides thirty-two points because each connected LLMux FTA supplies sixteen channels. This capacity depends on using the supported two-FTA architecture.
What cabinet-load allowance is needed before adding MU-TLPA02 51309204-125 to an existing 24 Vdc supply?
Reserve the documented 360 mA adapter demand and then add the MU-PLAM02, connected FTAs and remaining field loads. Using the adapter current alone would understate the complete LLMux load.