Features:
- Physical Barrier Between the Trusted TMR Chassis Slot and External Contaminants
- Integrates Environmental Shielding with Single-Width Slot Compatibility
- Functions Alongside Trusted I/O and Communication Modules
The ICS TRIPLEX T8191 serves as the Single Slot Width Shield in a Trusted TMR chassis, providing reliable physical protection to all modules within the system. It continuously blocks dust, moisture, dirt, and other industrial contaminants from entering the module slot, maintaining a clean internal environment across the rack to support steady-state operation of all monitors and modules. Seamless physical coverage is standard with the T8191, however using it in conjunction with active Trusted modules will ensure complete environmental isolation across the entire chassis configuration. The T8191 has been designed to meet rigorous functional safety standards in addition to incorporating single-width slot compatibility within the Trusted TMR rack.
The T8191 provides essential shielding functions common to the entire rack, and is a critical component of the physical protection path, directly affecting the proper, normal operation of the overall monitor system. One or more T8191 shields are required per rack depending on the number of vacant single-width slots. The T8191 occupies only a single-width slot in the rack and can be installed in any available slot position adjacent to active modules or in empty positions.
For complete chassis protection applications, the Trusted System requires T8191 shield modules installed in all unoccupied single-width slots. In addition to standard adjacent module protection, the shield configuration also performs continuous physical isolation. The Trusted TMR chassis executes environmental protection using the robust metal construction specified in the shield design. Using this method, the shield system continually blocks contaminants from entering the chassis. If the system configuration leaves a slot unoccupied or requires additional protection, installing the T8191 will automatically seal the opening and maintain the required environmental integrity without placing any load on the system power or data bus.
The T8191 ICS TRIPLEX Single Slot Width Shield may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
ICS TRIPLEX T8191 Single Slot Width Shield Module Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ICS TRIPLEX T8191 Single Slot Width Shield Module Specs
General
- Manufacturer ICS TRIPLEX
- Model T8191
- Condition New Original ready stock
- Product Family T8193,T8170,T8151
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Slot Blanking: Fills empty single-width spaces in a T8100 controller chassis.
- Airflow Optimization: Directs cooling air across active safety-critical modules.
- EMI Protection: Blocks electromagnetic interference from entering open slots.
- System Integrity: Keeps Safety Instrumented Systems running without disruption.
- Hot Swappable: Inserts safely while the controller remains powered.
- Vertical Mounting: Designed for chassis installed in standard vertical orientations.
- Toolless Fitting: Slides into any empty standard single-width slot.
- Physical Alignment: Locks securely into place to resist heavy industrial vibrations.
- Operating Temperature: Ranges from -25°C to +70°C (-13°F to +158°F).
- Storage Temperature: Ranges from -40°C to +85°C (-40°F to +185°F).
- Relative Humidity: Sustains 5% to 95% non-condensing environments.
- Harsh Conditions: Resists corrosive gas when ordered with conformal coating.