Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail info@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power provides global sourcing, competitive quotes, full technical documentation, and spare parts supply for Triconex 4409.

4409

/ 4.9
1001 reviews | Need a Specific Revision?
The Triconex 4409 Safety Manager Module is a high-availability communication interface engineered to connect a Tricon safety controller directly to a Honeywell TDC-3000 Distributed Control System via the Universal Control Network.
In Stock
Ships by Wednesday, September 30
Fast Shipping Available
Get a quick price for 4409
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 4409

  • Manufacturer:
    Invensys
  • Part Number:
    4409
  • Product Family:
    Triconex
  • Product Type:
    Safety Manager Module
  • Stock:
    1
  • Module Type:
    Safety Manager Module (SMM)
  • UCN Ports:
    2 isolated (AC coupled) F-Connectors for Redundant UCN Ports
  • UCN Data Rate:
    5 MBytes per second
  • Power Module Load:
    < 20 watts
  • Isolation:
    500 VDC
  • Mounting:
    Standard Tricon Main/Expansion Chassis Slot
  • Connectors:
    2 x F-Connectors (Redundant UCN Ports), 1 x DB-25P Connector (RS-232 Debug Port, for Triconex & Honeywell factory use only)
  • Operating Temperature:
    0°C to +60°C (32°F to 140°F)
  • Status Indicators:
    PASS, FAULT, ACTIVE, LOW BATT, SPARE RDY, UCN A, UCN B, XMIT, and a 4-character alphanumeric STATUS display
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Applications Diagnostics & Protection Communication & Connectivity Integration

Features:

  • Serves as a dedicated safety node interface on the Honeywell Universal Control Network (UCN).
  • Supports full 5 MBytes per second network data transmission speed.
  • Features dual AC-coupled isolated UCN ports for physical communication redundancy.
The Triconex 4409 Safety Manager Module (SMM) is available in brand new original packaging, fully tested surplus, or certified reconditioned condition, supplied with factory documentation where available.

This module enables full bi-directional data exchange between Tricon safety controllers and Honeywell TDC-3000 Distributed Control Systems, handling I/O reporting, alarm routing, sequence of events tracking, and clock synchronization.

Ensure proper slot keying and power module backplane capacity (< 20W) before insertion, and verify that UCN physical coaxial cabling is connected via front panel F-connectors.

The Triconex 4409 is subject to local stock availability and lead times confirmed by the manufacturer (OEM).
Triconex 4409 Safety Manager Module Manuals, Datasheets, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Integration of Tricon safety systems into Honeywell TDC-3000 DCS environments.
  • Real-time transmission of emergency shutdown (ESD) alarms to DCS consoles.
  • Centralized plant sequence of events (SOE) data collection and recording.
  • Includes a 4-character alphanumeric display for active SMM diagnostic codes.
  • Features discrete status LEDs including PASS, FAULT, ACTIVE, LOW BATT, and SPARE RDY.
  • Incorporates hardware write protection to block unauthorized changes from DCS sources.
  • Equipped with 2 isolated AC-coupled UCN ports using front panel F-Connectors.
  • Provides a dedicated DB-25P connector for factory RS-232 debug access.
  • Supports peer-to-peer messaging across multiple UCN-connected Tricon controllers.
  • Installs directly into standard Tricon Main, Expansion, or RXM chassis slots with mechanical keying protection.
  • Requires less than 20 watts of power module backplane load during active network operations.
  • Connects to the Honeywell UCN physical coaxial network via front panel AC-coupled F-connectors.
Description
Triconex 4409 Safety Manager Module (SMM) acts as a high-speed communication bridge connecting a Tricon safety system directly to a Honeywell TDC-3000 Distributed Control System via the Universal Control Network. The Triconex 4409 module operates as a safety node on the UCN, transmitting aliased data, system variables, and diagnostic status at full network speed to operator workstations in familiar display formats. This seamless integration ensures real-time visibility into critical process parameters without sacrificing safety system independence.

Designed for high-reliability industrial automation environments, the Triconex 4409 SMM handles critical I/O points, processes controller alarms, and propagates them directly to designated DCS consoles and printers. The module supports Sequence of Events data transmission to Universal Stations or History Modules, assisting operators in identifying the root cause of plant trips and reducing operational downtime. Additionally, the Triconex 4409 module features write protection capabilities to lock out unauthorized changes to the controller from any DCS source.

The Triconex 4409 module incorporates dual AC-coupled isolated UCN ports with F-connectors, providing physical redundancy for uninterrupted network communication across Honeywell UCN topologies. Engineered for complex multi-controller architectures, the Triconex 4409 SMM supports peer-to-peer communication and hot-spare deployment options. Built-in front-panel diagnostic LEDs and a four-character alphanumeric display deliver instant visual status feedback regarding node assignment, battery integrity, and module health.
Alternative Names
4409 4409 SMM Tricon 4409 4409-Triconex Invensys 4409 Schneider Electric 4409 4409 Safety Manager Module
Technical notes
The Triconex 4409 Safety Manager Module utilizes dual isolated AC-coupled F-connectors for redundant coaxial physical connections, equipped with hardware write-protection logic and dedicated backplane interface circuits for hot-swap operations
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What is the primary function of the Triconex 4409 Safety Manager Module?
The Triconex 4409 Safety Manager Module (SMM) acts as a specialized communication interface between a Tricon safety controller and a Honeywell Universal Control Network (UCN) within a Honeywell TDC-3000 DCS.
What is the maximum network data rate supported by the Triconex 4409 module?
The UCN ports on the Triconex 4409 module support full network transmission speeds of up to 5 MBytes per second.
How does the Triconex 4409 module transfer data to Honeywell workstations?
The Triconex 4409 module functions as a safety node on the UCN, relaying aliased safety data and diagnostic status directly to operator consoles in standard Honeywell display formats.
How does the Triconex 4409 module protect safety logic against external DCS modifications?
The Triconex 4409 module features built-in write protection functionality designed to lock out unauthorized control changes or updates originating from Honeywell TDC-3000 sources.
Does the Triconex 4409 module support Sequence of Events (SOE) tracking?
Yes, the Triconex 4409 module forwards detailed Tricon controller event records to Honeywell Universal Stations or History Modules for root-cause analysis.
Can the Triconex 4409 module synchronize system time with the Honeywell DCS?
Yes, the Triconex 4409 module receives clock synchronization directly from the Honeywell DCS master clock.