Features:
- Allows precise control of vibrator amplitude and frequency; 0.01 Hz steps for fine tuning.
- Disconnects output on overcurrent, short circuit, derating, or open circuit; protects both the controller and connected vibrator.
- Dust‑tight and protected against water jets; suitable for harsh industrial environments; protection class I (grounded); operating temperature 0‑50°C.
The 107230 allows independent adjustment of these two parameters. Output voltage (15‑30 Vss) controls the amplitude – higher voltage gives stronger vibration and faster material movement. Output frequency (10‑99.99 Hz) controls the rate of vibration – lower frequencies are used for coarse, heavy materials, while higher frequencies suit fine or sticky materials. The frequency can be set with 0.01 Hz resolution, allowing extremely fine tuning to avoid resonance or optimize flow.
Electromagnetic vibrators are inductive loads that can generate back‑EMF and draw high inrush currents. Connecting a vibrator without proper protection risks burning out the coil or damaging the controller. The 107230 includes multiple protection features. Overcurrent protection trips if the output current exceeds the safe limit, disconnecting the output. Short‑circuit protection immediately shuts down the output if a short occurs between output wires. Derating protection prevents operation if the unit overheats.
Industrial vibration applications are often found in dusty, wet, or washdown environments. A flour mill, food processing plant, or mining conveyor can expose electronic controllers to fine dust, water spray, or cleaning chemicals. The 107230 has an IP65 protection rating, meaning it is completely dust‑tight (first digit 6) and protected against low‑pressure water jets from any direction (second digit 5). However, this rating is only achieved when the connecting lines are screwed in place using proper cable glands.
The 107230 KOBERLEIN POWER BOX may still be available for purchase and support from Apter Power beyond
End-Of-Life (EOL)by the manufacturer (OEM).
KOBERLEIN 107230 POWER BOX Manuals, Datasheets,Drivers,Link
Important Notice:Other accessories,manuals,cables,calibration data,software,etc.are not included with this equipment unless listed in the above stock item description.All prices are shown in USD.
KOBERLEIN 107230 POWER BOX Specs
General
- Manufacturer KOBERLEIN
- Model 107230
- Condition New Original ready stock
- Product Family
107231,107232,107233
Important Notice:Other accessories,manuals,cables,calibration data,software,etc.are not
included with this equipment unless listed in the above stock item description.All prices are
shown in USD.
- Mobile Construction Machinery: Power distribution and control for excavators, cranes, agricultural machinery, and special vehicles.
- Automated Industrial Systems: As a power node in distributed control systems, used for power distribution to sensors, actuators, and PLCs.
- Harsh Environment Operations: Due to its high protection rating (typically IP6k-9k), it is commonly used in mines, tunnels, and industrial sites with high humidity and high vibration.
- On-board Energy Management: Used in commercial vehicles or buses for precise management of air conditioning, lighting, and auxiliary power systems.
- Channel-based Current Monitoring: Real-time monitoring of current values for each output channel.
- Overload and Short Circuit Protection: Features rapid circuit breaking to prevent systemic circuit burnout due to abnormal external loads.
- Self-diagnostic Alarm: Supports fault code feedback via bus (e.g., CAN bus, J1939 protocol) to accurately pinpoint which sensor or actuator has an open circuit, short circuit, or grounding fault.
- Thermal Protection Mechanism: Integrated temperature sensor automatically derating or disconnecting the circuit when the module overheats due to continuous high-power output.
- Physical Mounting: Install on a well-ventilated surface with minimal vibration. Use M6 or M8 bolts to secure the device, ensuring proper grounding of the metal casing to reduce electromagnetic interference (EMI).
- Wiring Specifications: Select the appropriate wire gauge for the main input power cable based on the rated total current. Ensure the sealing ring is in place when connecting the plug to maintain its waterproof performance.
- Firmware Updates: Upgrade the firmware via the module's built-in communication interface (usually a CAN bus) using the manufacturer's Service Tool software or flash memory tool.
- Configuration Parameter Adjustment: Without replacing the hardware, the current limit threshold, soft-start time, and logic trigger conditions for each channel can be adjusted via software.