HMS01.1N-W0350-A-07-NNNN

/ 4.9
1001 reviews | Need a Specific Revision?
Bosch Rexroth HMS01.1N-W0350-A-07-NNNN is an air-cooled IP20 IndraDrive M HMS01 inverter power section for one axis, using a 254–750 V DC bus and delivering three-phase motor output.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for HMS01.1N-W0350-A-07-NNNN
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for HMS01.1N-W0350-A-07-NNNN

  • Manufacturer:
    Rexroth
  • Part Number:
    HMS01.1N-W0350-A-07-NNNN
  • Product Family:
    Rexroth
  • Product Type:
    High-Current Single-Axis Inverter Power Section
  • Stock:
    1
  • Cooling / protection:
    Forced-air cooling; IP20
  • Rated DC input voltage:
    254–750 V DC
  • Rated input current:
    290.0 A
  • Output voltage:
    3 × AC 0–500 V
  • Rated output current:
    250.0 A
  • Maximum output current at 4 kHz:
    350.0 A
  • Continuous output current at 4 kHz:
    250.0 A
  • Continuous output current at 8 kHz:
    170.0 A
  • Allowed switching frequencies:
    4, 8 and 12 kHz
  • Control voltage:
    24 V DC ±20%
  • Rated control-voltage power:
    218 W, excluding motor holding brake, control section and safety option
  • Forced-air capacity:
    1400.00 m³/h
  • Ambient temperature:
    0 to 40°C at nominal data; operation with reduced nominal data up to 55°C
  • Derating:
    2% per K above the nominal ambient range
  • Minimum clearance:
    80 mm top; 100 mm bottom
  • Required companion hardware:
    HAB01 external fan unit; separate identity and supply connection at X13
  • Dimensions:
    35.0 × 44.0 × 26.2 cm
  • Weight:
    31.7 kg
  • Tariff Code:
    8503009090
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Fan Integration Mechanical Support Duty Validation Application
  • Use the 250 A continuous-output value at 4 kHz and 170 A value at 8 kHz for thermal sizing
  • Install and power the required HAB01 fan unit; it is not an optional cooling accessory for this size
  • Account for the 350 A maximum-current class, 218 W control-power demand and 1400 m³/h airflow requirement

HMS01.1N-W0350-A-07-NNNN is a Bosch Rexroth IndraDrive M HMS01 single-axis inverter power section that requires an external HAB01 fan unit.

Its 254–750 V DC-bus input supports up to 350 A maximum output, with continuous current limited to 250 A at 4 kHz and 170 A at 8 kHz.

Before load operation, verify the HAB01 fan supply and airflow direction, mechanical support, DC-bus and motor connections, control section, firmware and temperature behavior throughout the duty cycle.

Availability, condition, price, and shipping time for HMS01.1N-W0350-A-07-NNNN are confirmed during quotation.

Bosch Rexroth HMS01.1N-W0350-A-07-NNNN High-Current Single-Axis Inverter Power Section Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • Install the documented HAB01 external fan arrangement
  • Verify X13 supply, fan direction and diagnostic condition
  • Keep cabinet inlet and exhaust paths clear at full airflow
  • Allow for the 350 mm width and 31.70 kg power-section mass
  • Support heavy bus and motor cables independently of terminals
  • Preserve service access to the control section and fan unit
  • Use only the published 4, 8 or 12 kHz operating data
  • Coordinate common-bus and regenerative energy for the full lineup
  • Test the worst-case thermal cycle with the HAB01 operating
  • Single-axis operation in a Rexroth IndraDrive M HMS01 system
  • Three-phase asynchronous motor operation
  • Three-phase synchronous motor operation
Description
HMS01.1N-W0350-A-07-NNNN is a Bosch Rexroth high-current single-axis inverter power section in the IndraDrive M HMS01 family.

Bosch Rexroth HMS01.1N-W0350-A-07-NNNN is an air-cooled IP20 IndraDrive M HMS01 inverter power section for one axis, using a 254–750 V DC bus and delivering three-phase motor output. The complete code identifies the IndraDrive M HMS01 power section, air cooling, current class and A-07-NNNN design. It is not a complete drive controller by itself: the control section, firmware and required system components are separate identities.

Before installation or replacement, confirm the complete HMS01.1N-W0350-A-07-NNNN type plate, separate control section, power and motor connections, cooling arrangement, firmware and commissioned parameters.
Alternative Names
HMS01.1N-W0350-A-07-NNNN HMS01 1N W0350 A 07 NNNN HMS011NW0350A07NNNN Bosch Rexroth HMS01.1N-W0350-A-07-NNNN Rexroth HMS01.1N-W0350-A-07-NNNN
Technical notes
HMS01.1N-W0350-A-07-NNNN is an inverter power section, not a complete drive controller; the control section and firmware remain separate. Match the full type plate, DC-bus supply, motor data, cooling and commissioned parameters before replacement.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Is the HAB01 fan unit optional for HMS01.1N-W0350-A-07-NNNN?
No for the documented arrangement shown in the manual. The W0350 dimensional drawing uses the external HAB01 fan unit, and its identity, mounting, power and condition must be verified separately.
Where is the fan supply connected for HMS01.1N-W0350-A-07-NNNN?
The official connection overview identifies X13 as the voltage connection for the fan unit. Follow the detailed connection instructions and never infer voltage or pinout from a smaller HMS01.
What should happen if the HAB01 fan stops while HMS01.1N-W0350-A-07-NNNN is operating?
The machine must follow its approved controlled-stop or drive-disable response before the power section exceeds its thermal limit. Do not continue operation by repeatedly resetting warnings; check the fan supply, rotation, airflow path and monitoring circuit first.
Why can HMS01.1N-W0350-A-07-NNNN overheat even though the HAB01 fan is running?
The fan may have the wrong airflow direction or insufficient delivery because of an incorrect variant, low supply voltage, blocked inlet, dirty filter, restricted ducting or hot-air recirculation. Verify airflow at the converter rather than relying only on fan noise or rotation.
Can HMS01.1N-W0350-A-07-NNNN replace W0300 without changing the cabinet?
No. The W0350 is wider, much heavier and uses the external fan arrangement; electrical ratings, cable routing, airflow and mechanical support all require review.
Can any HAB01 fan unit be paired with HMS01.1N-W0350-A-07-NNNN?
No. Confirm the approved HAB01 part number, supply voltage and frequency, airflow rating, mounting arrangement, connector and rotation direction. Similar appearance does not establish cooling or electrical compatibility.
When should the HAB01 fan start and stop relative to HMS01.1N-W0350-A-07-NNNN drive enable?
Establish the documented airflow before applying load or enabling torque, and maintain cooling for the required operating or post-run period. Where the machine design permits, interlock drive enable with confirmed fan operation rather than relying on manual switching.