Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power confirms MXQ8-10P-M9BVL switch orientation and current supply at enquiry.

MXQ8-10P-M9BVL

/ 4.9
1001 reviews | Need a Specific Revision?
SMC MXQ8-10P-M9BVL is an MXQ air slide table with 8 mm bore, 10 mm stroke, axial piping and a perpendicular-entry 3 m two-wire solid-state auto-switch configuration.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for MXQ8-10P-M9BVL
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for MXQ8-10P-M9BVL

  • Manufacturer:
    SMC
  • Part Number:
    MXQ8-10P-M9BVL
  • Product Family:
    SMC
  • Product Type:
    MXQ Air Slide Table
  • Stock:
    1
  • Series:
    MXQ
  • Bore Size:
    8 mm
  • Stroke:
    10 mm
  • Piping:
    Axial
  • Auto Switch:
    M9BVL solid-state
  • Switch Wiring:
    2-wire
  • Switch Entry:
    Perpendicular
  • Lead Wire Length:
    3 m
  • Switch Voltage:
    24 VDC (10–28 VDC)
  • Estimated shipping dimensions:
    5.3x3.8x2.3cm
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    Japan
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Cable Clearance Port Integration Position Acceptance Product Applications

Features:

  • Perpendicular switch entry: The M9BVL lead exits across the sensor body to suit a different clearance envelope.
  • Short guided stroke: The integrated MXQ table provides controlled 10 mm travel.
  • Axial air connection: The P code fixes the pneumatic port orientation for machine routing.
This configuration exists for installations where the perpendicular sensor lead better clears surrounding tooling or machine covers.

The slide delivers compact guided pneumatic movement while the two-wire switch reports an accepted table position.

Selection should preserve both cable-exit geometry and the axial pneumatic route instead of matching only bore and stroke.

Apter Power can help source the SMC MXQ8-10P-M9BVL MXQ Air Slide Table after perpendicular switch entry and port orientation are matched to the machine.
SMC MXQ8-10P-M9BVL MXQ Air Slide Table Manuals,Datasheets,Link
Important Notice: No qualified exact-model English PDF is attached. Use the complete product model in every document request.
  • Perpendicular exit: Reserve side clearance for the M9BVL lead and connector transition.
  • Moving envelope: Observe the lead through repeated strokes before closing guards.
  • Strain relief: Support the 3 m cable without loading the switch body.
  • Variant control: Keep M9BVL and in-line M9BL spares separated by full order code.
  • Axial piping: Use fittings and tubing that preserve access to the P-oriented ports.
  • Tube movement: Keep the pneumatic line outside the table and sensor travel envelope.
  • Controlled speed: Commission flow so the short stroke stops without repeated end impact.
  • Leak check: Prove the circuit holds pressure before diagnosing position-signal behavior.
  • Mechanical first: Confirm the table reaches both accepted ends without binding.
  • Switch response: Check the two-wire signal changes at the intended sensing point.
  • Guard clearance: Verify the perpendicular cable remains free throughout operation.
  • Cycle proof: Run a controlled sequence with the final fixture and tubing installed.
  • Compact transfer stations: Moves small parts over a short guided path.
  • Side-clearance layouts: Uses perpendicular sensor cable entry where in-line routing is obstructed.
  • Pneumatic indexing: Provides two-position motion with controller feedback.
  • Integrated fixture motion: Carries a small tooling plate without a separate linear guide.
Description
Perpendicular sensor-cable routing distinguishes MXQ8-10P-M9BVL within the compact MXQ8 10 mm-stroke air slide family, helping the lead clear in-line obstacles.

The guided table and axial piping of MXQ8-10P-M9BVL support short pneumatic positioning while the M9BVL solid-state switch returns a two-wire position signal to the controller.

For MXQ8-10P-M9BVL, the final V in the switch code is operationally important: preserving that entry direction can avoid cable interference after a visually similar slide is replaced.
Alternative Names
MXQ810PM9BVL MXQ8 10P M9BVL
Technical notes
The M9BVL suffix on MXQ8-10P-M9BVL specifies a perpendicular cable entry. Installing the in-line M9BL variant can place the lead into tooling or guards even when the actuator body fits. Preserve the switch orientation, 3 m lead route and strain relief before the table is allowed to cycle.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
A replacement MXQ8-10P-M9BVL has the cable exiting in line with the switch. Should installation continue?
No. That geometry indicates a different switch entry; stop and compare the full M9BVL code before mounting the slide.
The two-wire input remains on while MXQ8-10P-M9BVL moves. Is the pneumatic circuit the first suspect?
Not necessarily. Check the M9BVL sensing position and input wiring before changing air flow, because the table can move normally while the signal path is mis-set.
Can MXQ8-10P-M9BL be used when MXQ8-10P-M9BVL is unavailable?
Only after confirming the in-line cable exit will clear the machine. The actuator size and stroke match, but the sensor routing decision changes.
Tubing contacts the sensor lead on MXQ8-10P-M9BVL. May the lead be tied against the moving table?
No. Reroute and support both systems outside the travel envelope so neither pneumatic tubing nor the switch cable loads the moving assembly.
MXQ8-10P-M9BVL stalls after a fixture change. What should be ruled out before replacing the slide?
Remove the new fixture load and check mounting distortion plus external moment; a sensor orientation change will not resolve mechanical binding.
How should a technician validate MXQ8-10P-M9BVL after installation?
Run a controlled full cycle and prove both mechanical end positions, M9BVL signal transitions, tubing clearance and perpendicular cable clearance before production release.