490NRP25300

/ 4.9
1001 reviews | Need a Specific Revision?
Schneider Electric 490NRP25300 is a point-to-point fiber optic repeater that extends Modbus Plus communication over multimode fiber while helping maintain reliable data transmission in electrically noisy industrial environments.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 490NRP25300
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 490NRP25300

  • Manufacturer:
    Schneider Electric
  • Part Number:
    490NRP25300
  • Product Family:
    Modicon Quantum
  • Product Type:
    Fiber Optic Repeater
  • Stock:
    1
  • Modbus Plus bridges and repeaters characteristics:
    Repeater Between pins
  • Transmission support medium:
    Fiber optic
  • Accessory / separate part type:
    Point-to-point fibre optic repeater
  • Range of product:
    Modicon Premium/Quantum automation platform Modicon Quantum
  • Weight:
    2.9 kg
  • Estimated shipping dimensions:
    34x27x12cm
  • Tariff Code:
    8517623990
  • Country of origin:
    France
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Application Scenarios Communication Compatibility

Features:

  • Provides a point-to-point fiber optic communication link between Modbus Plus network sections.
  • Uses multimode fiber to extend communication paths while reducing exposure of the optical section to electromagnetic interference.
  • Combines an electrical Modbus Plus interface with a fiber optic transceiver for integration into Modicon Premium and Modicon Quantum automation networks.
Schneider Electric 490NRP25300 provides a practical communication link for industrial control systems where Modbus Plus devices are distributed across separate production areas, buildings, or process sections. Rather than keeping the entire network on electrical cable, the repeater introduces a fiber optic section between two Modbus Plus connections. The arrangement supports network expansion while maintaining communication between connected PLC equipment. Applications can include large manufacturing lines, electrical monitoring systems, transportation infrastructure, water treatment facilities, and process plants. Fiber transmission can be especially useful where conventional network cabling would pass through electrically demanding industrial environments.

A key application value of 490NRP25300 comes from the point-to-point network structure. One electrical Modbus Plus interface communicates through one fiber optic transceiver, creating a dedicated optical link between two network sections. The architecture allows separated network areas to remain part of the same industrial communication system without requiring continuous electrical cabling across the entire route. Optical path planning should consider cable attenuation, connector losses, splices, and available optical power margin. Schneider Electric documentation recommends graded-index multimode glass fiber for the repeater family.

For maintenance personnel, Schneider Electric 490NRP25300 also provides status indication for power, Modbus Plus activity, and the fiber port. Such indicators can assist during commissioning and fault isolation when communication is interrupted between network sections. Schneider Electric troubleshooting guidance uses two 490NRP25300 repeaters in a point-to-point configuration and identifies LED behavior as part of network diagnosis. Combined with the repeater's fiber optic communication function, the arrangement supports dependable operation in distributed automation systems where communication continuity is important to overall process availability.

The 490NRP25300 Schneider Electric Fiber Optic Repeater may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Schneider Electric 490NRP25300 Fiber Optic Repeater Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Schneider Electric 490NRP25300 Fiber Optic Repeater Specs

General

  • Manufacturer Schneider Electric
  • Model 490NRP25300
  • Condition New Original ready stock
  • Product Family 490NRP25400,490NAA27103
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Mine Belt Conveyor: Deployed in underground or surface ore transportation networks spanning several kilometers, connecting various section control boxes.
  • Petrochemical Storage Tank Monitoring: Used for long-distance data communication between explosion-proof areas and the main control room, ensuring absolute electrical safety.
  • Cement Clinker Production Line: Acts as a communication relay in high-noise workshops filled with dust, ensuring real-time command delivery from the central control room.
  • Paper Mill Machinery Network: Distributed across various speed control sections of large paper mill units, resolving electromagnetic interference from frequency converters.
  • Sewage Pump Station Cascading: Connects sewage lifting pump stations scattered over several kilometers into a unified network via a fiber optic backbone.
  • Protocol Conversion: This repeater is specifically designed to seamlessly convert industrial bus data in electrical form to fiber optic signals.
  • Transmission Rate: Maintains a stable standard data throughput and clock synchronization rate of 1 Mbps in dedicated industrial networks.
  • Signal Isolation: Provides full-duplex electrical isolation based on the physical characteristics of optical signals, completely eliminating ground loop interference.
  • Long-Distance Transmission: Employs high-performance optoelectronic components, significantly extending the physical communication distance of a single bus segment to several kilometers.
  • Network Topology: Supports the construction of point-to-point straight-line links in complex industrial environments, expanding network coverage boundaries.
  • Network Protocol: The hardware is deeply optimized and proprietaryly matched for the Modbus Plus network architecture.
  • Fiber Optic Specification: Compatible only with multimode fiber standards; does not support single-mode fiber or plastic fiber media.
  • Physical Interface: Equipped with dedicated high-reliability fiber optic connectors to ensure low insertion loss during optical path connection.
  • Backplane Power Supply: Compatible with Modicon series-specific standard power inputs, allowing direct embedding within the system rack.
  • Hardware Collaboration: Plug-and-play communication with the Modicon Premium and Quantum controller master station.
Description
Schneider Electric 490NRP25300 is a fiber optic repeater for Modbus Plus networks within Modicon Premium and Modicon Quantum automation platforms. The unit provides a point-to-point optical connection between two Modbus Plus network sections, combining an electrical Modbus Plus interface with a fiber optic transceiver. Converting the communication path to optical fiber helps extend network connections beyond conventional electrical cable installations and provides a practical method for linking separated control areas.

In industrial plants, 490NRP25300 can be used where communication paths pass through areas affected by electromagnetic or radio-frequency interference. Fiber optic transmission does not depend on electrical signal conduction along the communication medium, making the repeater suitable for distributed PLC networks in power monitoring, heavy industry, metallurgy, transportation systems, water treatment, and process control installations. The repeater regenerates the communication signal between network sections so that attenuation along the transmission path can be managed more effectively.

Schneider Electric 490NRP25300 operates with multimode fiber rather than single-mode fiber. Schneider Electric specifically identifies multimode fiber for 490NRP25300, while the repeater guide recommends 62.5/125 µm graded-index multimode glass fiber for general applications. The documented optical interface uses ST-type connectors and an 820 nm optical wavelength, with point-to-point distances dependent on fiber size, attenuation, connectors, splices, and the total optical power-loss budget. The documented operating temperature range is 0°C to 60°C, while storage temperature extends from -40°C to +85°C with 10% to 95% non-condensing humidity.
Alternative Names
49ONRP253OO 490NRP25400 490NAA27103 140CPU43412A TSXCAP030 140XBE10000 140DDO35300 140DDI35300
Technical notes
Optimized for Modicon automation platforms, the Schneider 490NRP25300 repeater enables seamless multi-mode fiber optic bridging for long-distance topology expansions. Featuring an IP20 rated chassis, it provides robust 100% optical immunity against high-voltage electromagnetic surges in demanding process plants.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How does Schneider Electric 490NRP25300 help extend communication distance?
The repeater receives and retransmits communication through a fiber optic point-to-point link. Actual allowable distance depends on fiber attenuation, connectors, splices, and the total optical loss budget rather than a single universal cable-length value.
Can 490NRP25300 operate with single-mode fiber?
No. Schneider Electric specifies multimode fiber for 490NRP25300. The repeater documentation recommends graded-index multimode glass fiber, particularly 62.5/125 µm fiber for general installations.
What optical wavelength does 490NRP25300 use?
The fiber optic repeater specification identifies an optical wavelength of 820 nm. Fiber selection and attenuation calculations should therefore be based on the optical characteristics specified for the repeater and installed cable.
Does Schneider Electric 490NRP25300 support point-to-point communication?
Yes. Point-to-point operation is the defined Modbus Plus application for 490NRP25300. The repeater contains one fiber optic transceiver and one electrical Modbus Plus interface for connecting two network sections.