Features:
- Clear-text screens present drive parameters and diagnostic messages.
- A dedicated OPM2 cable carries commands between panel and drive.
- The connected drive retains parameter storage and motor-control responsibility.
Siemens 6SE3290-0XX87-8BF0 provides a local interface to supported integrated drives.
Panel keys select and edit drive parameters while the display identifies the active value or fault.
Supply, cable, connector, and drive status define the communication path.
The Siemens 6SE3290-0XX87-8BF0 OPM2 Clear Text Operator Panel may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6SE3290-0XX87-8BF0 OPM2 Operator Panel Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Parameter and Fault Display
- Parameters: The panel shows selected drive settings as readable text.
- Diagnostics: Fault information appears through the same display interface.
- Languages: The operator selects from the supported clear-text languages.
- Boundary: Displayed information originates from the connected drive.
OPM2 Communication Path
- Cable: A dedicated OPM2 interface cable connects panel and drive.
- Commands: Key actions travel to the drive over that interface.
- Response: The drive returns parameter values and diagnostic states.
- Check: Connector seating and cable continuity precede parameter troubleshooting.
Local Drive Configuration
- Selection: Navigation keys choose the required drive parameter.
- Editing: Permitted values can be changed through the panel.
- Storage: The drive stores accepted parameter changes.
- Control boundary: Motor-control execution remains inside the drive.
Panel Supply and Current Limits
- Supply: The panel requires 6 V DC within ±0.5 V.
- With drive: Maximum current is 50 mA when connected to the drive.
- Without drive: Maximum current is 250 mA without the drive connection.
- Diagnosis: Verify supply and interface status when the display remains blank.