Features:
- Moves the standard MASTERDRIVES PMU parameterizing unit to a cabinet door.
- Includes a 2 m cable between the door-mounted PMU and the drive equipment.
- Accepts an OP1S panel on the PMU after the adapter is installed.
Use the complete 6SX7010-0AA10 order number when selecting the cabinet-door adapter because it includes the PMU connection cable arrangement.
Set the cabinet cutout and mounting position so the parameter unit remains accessible while its cable reaches the drive without sharp bends.
After installation, confirm keypad communication and display operation before the door is closed and normal drive commissioning resumes.
The Siemens 6SX7010-0AA10 SIMOVERT MASTERDRIVES APMU Door-Mount Adapter may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6SX7010-0AA10 SIMOVERT MASTERDRIVES APMU Door-Mount Adapter Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Sizing the enclosure opening around the APMU frame
- Cutout: Prepare a 78.5 x 179.5 mm opening for the rear body.
- Front outline: Reserve the 84 x 186 mm area covered by the mounted frame.
- Sheet thickness: Use a door panel within the documented 0.5 to 4 mm range.
- Rear space: Keep at least 30 mm free behind the assembly for the connection.
Keeping the operator unit connected after it moves to the door
- PMU seat: The standard parameterizing unit fits into the APMU frame.
- Cable link: The supplied 2 m cable reaches back to the MASTERDRIVES equipment.
- Control path: Keys and display continue to serve the connected drive through that cable.
- No duplicate unit: The adapter relocates the PMU rather than adding a second parameterizing unit.
Adding the optional panel to the mounted PMU
- Front plug-in: The OP1S panel engages the PMU at the cabinet front.
- Mechanical stack: Both panel and PMU rely on the APMU frame for door support.
- Cable dependency: Communication still returns through the APMU cable.
- Clearance check: Verify the complete front and rear stack before closing the door.
Protecting the 2 m connection inside the enclosure
- Bend path: Route the cable without a sharp bend behind the door.
- Door movement: Leave enough controlled slack for the enclosure door to open.
- Separation: Keep the operator cable away from high-current conductors where practical.
- Connector seating: Secure both cable ends before testing PMU communication.