Technical specifications for 6AV2128-3QB06-0AX1

  • Manufacturer:
    Siemens
  • Part Number:
    6AV2128-3QB06-0AX1
  • Product Family:
    Siemens Simatic HMI
  • Product Type:
    SIMATIC HMI MTP1500 Unified Comfort Panel
  • Stock:
    1
  • Design of display:
    TFT
  • Screen diagonal:
    15.6 in
  • Number of colors:
    16 777 216
  • Horizontal image resolution:
    1 366 pixel
  • Vertical image resolution:
    768 pixel
  • MTBF backlighting:
    50 000 h at 25 °C
  • Backlight dimmable:
    Yes; 10 ... 100%
  • Design as multi-touch screen:
    Yes
  • Mounting in portrait format possible:
    Yes
  • Rated value (DC):
    24 V
  • Permissible range (DC):
    19.2 ... 28.8 V
  • Current consumption (rated value):
    0.7 A
  • Current consumption, max.:
    1.3 A
  • Number of industrial Ethernet interfaces:
    2; 2 ports (switch) + independent port
  • Number of RS 485 interfaces:
    1; RS 422 / 485 combined
  • Number of USB interfaces:
    4; USB 3.1 Gen. 1 (type A)
  • Number of SD card slots:
    2
  • Supports protocol for PROFINET IO:
    No
  • Weight:
    9.48 lbs (4.3 kg)
  • Estimated shipping dimensions:
    30×46×14 cm
  • Tariff Code:
    85285210
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Touch Workflow Network Segmentation Unified Runtime Backup & Transfer

Features:

  • Multi-touch operation combines gesture input with onscreen numeric and alphanumeric keyboards.
  • A switched Ethernet pair and an independent Ethernet interface support separate network paths.
  • Role-based access is managed within the WinCC Unified runtime.
The hardware and software clocks of Siemens 6AV2128-3QB06-0AX1 can be synchronized, with a typically six-week retentive period.

A buzzer is installed in Siemens 6AV2128-3QB06-0AX1, while a speaker is not fitted; Ethernet status LEDs provide local network indication.

One Siemens 6AV2128-3QB06-0AX1 project can contain up to 32 runtime languages, 50 roles and 200 users.

The Siemens 6AV2128-3QB06-0AX1 SIMATIC HMI MTP1500 Unified Comfort Panel may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6AV2128-3QB06-0AX1 SIMATIC HMI MTP1500 Unified Comfort Panel Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

MTP1500 Operator Actions

  • Gesture handling: Multi-touch input lets configured screen objects respond to gesture-based operation.
  • Numeric entry: An onscreen numeric keyboard appears when the project requests number input.
  • Text entry: Alphanumeric fields use an onscreen keyboard instead of a fixed front keypad.
  • Access control: Project roles determine which users can operate protected runtime functions.

Ethernet and Serial Routing

  • Line-through path: Two Ethernet connectors share the integrated switch for one network segment.
  • Independent path: The additional Ethernet interface can be assigned to a separate network.
  • Serial route: The combined RS422/485 interface carries supported serial communication.
  • Role boundary: PROFINET communication is available, but PROFINET IO device operation is not supported.

Project Data Functions

  • Language set: A project can contain 32 runtime languages for configured operator screens.
  • Alarm records: Alarm archives retain configured event histories on supported storage media.
  • Process records: Process-value and short-term archives store selected runtime values.
  • User administration: Roles, users and password import or export are handled inside the Unified runtime.

Project Service Paths

  • Backup mode: Manual and automatic backup or restore functions preserve configured panel data.
  • Ethernet loading: Engineering projects can be transferred through the Ethernet connection.
  • External media: Project transfer from external media is available from WinCC Unified V17.
  • Device switchover: The service functions include switching a configured project to replacement panel hardware.
Description
Siemens 6AV2128-3QB06-0AX1 is the SIMATIC HMI MTP1500 Unified Comfort Panel, a multi-touch operator panel in the Unified Comfort family. It presents machine and process information while executing projects created with WinCC Unified Comfort Engineering.

Operator interaction on 6AV2128-3QB06-0AX1 combines gesture-capable touch input with onscreen numeric and alphanumeric keyboards. Configured screens can organize alarms, trends, recipes and process objects without a fixed front-key matrix.

Controller communication for 6AV2128-3QB06-0AX1 includes S7-1200, S7-1500, S7-300 and S7-400 connections, with as many as 16 S7 connections available to the project. The switched Ethernet path and the independent Ethernet interface allow separate network roles to be assigned.

Both landscape and portrait installation are supported by 6AV2128-3QB06-0AX1, with a lower permissible ambient limit in portrait orientation. The panel front and rear have different enclosure boundaries, so cabinet installation determines which protection level applies.
Alternative Names
Siemens 6AV2128-3QB06-0AX1 6AV21283QB060AX1 6AV2128 3QB06 0AX1 6AV2128-3QB06-OAX1 6AV2128-3QB06-0AXI SIMATIC HMI MTP1500 6AV2128-3QB06-0AX1 MTP1500 Unified Comfort Panel 6AV2128-3QB06-0AX1 6AV2128-3QB06-0AX1 HMI Panel
Technical notes
Siemens 6AV2128-3QB06-0AX1 supports hardware and software clocks, clock synchronization and a typically six-week retentive clock period.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why must the PROFINET role be checked before assigning 6AV2128-3QB06-0AX1 as an IO device?
Although 6AV2128-3QB06-0AX1 communicates over PROFINET, its PROFINET IO device protocol field is No, so the intended device role must be checked.
Which temperature limit applies when 6AV2128-3QB06-0AX1 is rotated into portrait format?
For 6AV2128-3QB06-0AX1, portrait installation is limited to 0 ... 40 °C, while landscape installation permits 0 ... 50 °C.
Can USB be selected as the direct project-transfer path for 6AV2128-3QB06-0AX1?
No. Direct USB transfer is not supported by 6AV2128-3QB06-0AX1; Ethernet transfer is supported, and external-media transfer is available from WinCC Unified V17.
How should the Ethernet connectors on 6AV2128-3QB06-0AX1 be divided between networks?
Two connectors on 6AV2128-3QB06-0AX1 belong to the integrated switch, while the remaining connector is an independent Ethernet interface.
What engineering baseline must be present before opening a project for 6AV2128-3QB06-0AX1?
A project for 6AV2128-3QB06-0AX1 requires WinCC Unified Comfort Engineering V16 or later, so conventional Comfort Panel project support should not be assumed.
Where can runtime archives from 6AV2128-3QB06-0AX1 be stored?
Alarm and process-value archives from 6AV2128-3QB06-0AX1 can be stored on a memory card or USB mass storage; Ethernet is not listed as an archive location.