Supplied with every order

  • Commercial invoice and packing list
  • Nameplate and packaging photographs
  • 12-month Apter Power warranty
Need a specific document format for your import process? Say so in the enquiry and we will confirm before you order.

Recommended to use with 6ES7924-0CD00-0AB0

All in stock · Add one and it is quoted together with the model, one shipping cost.

6ES7924-0CD00-0AB0

Siemens 6ES7924-0CD00-0AB0 is a SIMATIC TPR relay terminal block that converts eight 24 V DC control signals into isolated normally open relay outputs for field loads.

In Stock Ships by Wednesday, November 25 Fast Shipping Available
Dispatched within 24 hours of a confirmed order.
Nameplate and packaging photographs supplied before dispatch.
ISO 9001:2015 certified

Industry compliance and certified quality in every part we supply.

View certificate

Get a price for 6ES7924-0CD00-0AB0

6ES7924-0CD00-0AB0Siemens SIMATIC TPR Relay Terminal Block
Edit or add anything — monitor type, cable length, other part numbers.

Tell us which and we will shape the quote around it.

Attach a nameplate photo and an engineer will confirm the exact part number before quoting.

Answered within 2 working hours, Mon–Fri 09:00–18:00 GMT+8. Used only for this quotation.

Your Quote Request Has Been Received

Thank you. Our sales team will review your request and contact you shortly.

Ordering, delivery and after-sales

Your account managerNamed, start to finish

Your enquiry is picked up by a named account manager who checks the configuration before pricing and stays with the order through dispatch and after-sales. You are not passed round a shared inbox.

  • Direct email and WhatsApp for that person
  • Quotation signed by whoever prepared it
  • Same contact if anything needs sorting later

Enquiries are answered within 2 working hours, Mon–Fri 09:00–18:00 GMT+8.

Warranty12 months from shipment

Twelve months from date of shipment against functional defects under normal operating conditions. Because Apter Power is an independent supplier, the manufacturer’s own warranty does not apply — ours stands in its place, which on a discontinued part is the only cover there is.

If it arrives faulty or does not fitReturn authorisation same day

A written procedure, not a negotiation.

  • Report the fault within the 12-month warranty period
  • We issue a return authorisation the same working day
  • Return the unit within 14 days of reporting, in antistatic packaging where applicable
  • Replacement, repair or refund at our option, confirmed in writing
  • Return shipping on a confirmed warranty defect is at our cost

If it turns out to be a configuration mismatch rather than a fault, we help you identify the correct part instead of leaving you with the wrong one.

Pre-dispatch inspectionWhat we check — and what we don’t

Checked:

  • Part number and revision read from the unit nameplate, and photographed
  • Outer packaging and seals inspected and photographed
  • Connector threads and mounting stud checked for damage
  • Quantity and accessory contents verified against the packing list

Not checked: no powered functional or calibration test is performed on this item; sensitivity and frequency response are not re-certified by Apter Power; no hazardous-area certification is issued by us. If you need a functional test report before shipment, ask when you request the quote and we will confirm whether it is possible and what it adds to the lead time.

Our quality management is certified to ISO 9001:2015. More usefully, the scope above is published rather than summarised as “tested and approved” — nothing is implied that we did not do.

Shipping, customs and documentsDispatch in 24h · 170+ countries

Dispatch within 24 hours of a confirmed order for items held in stock. DHL, FedEx and UPS express to 170+ countries, typically 3–6 working days door to door; tracking is emailed the day the order leaves us. Shipping method and cost are itemised on every quotation and never added afterwards.

Most delays on an international spare are paperwork rather than freight, so the documents are prepared before the parcel leaves:

  • Commercial invoice and packing list on every shipment
  • Certificate of Origin prepared on request — ask at enquiry stage
  • HS code stated on the quotation, not discovered at clearance
  • We work to your broker’s format if you tell us what it is
PaymentTelegraphic transfer only

We accept payment by telegraphic transfer (T/T) only. Bank details appear on the pro-forma invoice and nowhere else — we never send revised bank details by email after quoting. If you receive a message claiming our account has changed, call +86 15359408275 before paying.

How to orderSend the part number

Send the enquiry above, or email the part number, quantity and destination country. In-stock items show a live quantity; where a part is not held we show "Ask" and confirm availability from our supplier network before quoting, so you are never quoted a lead time we cannot meet.

Discover the experience, people and global sourcing expertise behind Apter Power. About us »

Technical specifications

 set by the part-number suffix dotted  awaiting confirmation against the OEM datasheet

Part identification

Manufacturer
Siemens
Part Number
6ES7924-0CD00-0AB0
Product Family
Siemens Simatic S7-300
Product Type
SIMATIC TPR Relay Terminal Block
Stock
1
Tariff Code
85389099
Country of origin
Germany
Place of shipment
Xiamen,Fujian,China

More information

Features:

  • Maps eight 24 V DC control inputs to eight normally open relay contacts.
  • Keeps controller-side signals electrically separate from external load power.
  • Uses spring terminals to organize input and load conductors by channel.
Each input drives only its corresponding relay, making the channel relationship traceable from controller command to field load.

The contact path switches external AC or DC power and does not derive load voltage from the control input.

Contact rating, suppression and operating frequency are evaluated for the actual connected device.

The Siemens 6ES7924-0CD00-0AB0 SIMATIC TPR Relay Terminal Block may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6ES7924-0CD00-0AB0 SIMATIC TPR Relay Terminal Block Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Tracing eight commands to eight relay contacts

  • Input identity: Each 24 V DC input is labeled with its corresponding relay channel.
  • Relay action: An active input closes only the paired normally open contact.
  • Output identity: The load conductor and return path are recorded for the same channel number.
  • Proof test: Channels are energized one at a time before group operation.

Keeping field current within the relay rating

  • AC circuit: An AC load is checked against the documented 230 V and 2 A boundary.
  • DC circuit: A DC load follows the lower documented voltage and current limit.
  • Inrush: Coils, lamps and capacitive loads are assessed for starting current.
  • Suppression: Inductive energy is controlled at the load with the specified device.

Separating control and load conductors

  • Input side: Controller signals and their common remain on the designated input terminals.
  • Contact side: External supply and load wiring use the relay-contact terminals.
  • Spring clamp: Conductor preparation allows the clamp to hold without exposed strands.
  • Labeling: Both ends of every conductor carry the same channel and circuit identity.

Finding a missing field response efficiently

  • Input state: Measure whether the 24 V DC command reaches the intended channel.
  • Relay state: Listen or test for the corresponding contact change.
  • Load supply: Confirm external voltage and return continuity on the contact side.
  • Device condition: Check the connected load and suppression component before replacing the terminal block.

Description

Siemens 6ES7924-0CD00-0AB0 is a SIMATIC TPR relay terminal block that interfaces eight 24 V DC controller signals with eight field-load circuits. Each input energizes its corresponding relay, causing one normally open contact to switch the external load supply.

Control voltage enters 6ES7924-0CD00-0AB0 on the input side while AC or DC load power remains on the contact side. This separation lets low-voltage controller commands operate field circuits without routing the load current through the controller output channel.

The eight channels of 6ES7924-0CD00-0AB0 follow a one-to-one input-to-contact relationship. Spring terminals organize the conductor landing points, and each channel label links one control input with its corresponding load circuit.

Load selection for 6ES7924-0CD00-0AB0 depends on both voltage type and permissible current: the documented AC rating differs from the DC rating. Inductive loads also require the specified suppression so contact arcing does not shorten relay life or disturb adjacent control signals.

Case studies

Order from our published case studies. Each one names the customer situation, the parts involved and what changed.

Yuki
Sudan9 ABB models · 20 components

After Six On-Site Reviews, a Sudanese Integrator Selects Apter Power for 20 Scarce ABB Components

After a two-to-three-year evaluation and five to six on-site visits, a Sudanese system integrator selected Apter Power from more than ten global suppliers for nine scarce ABB models and 20 components.

9Scarce ABB models
20Components supplied
“ This gave us the confidence to consolidate the order with one supplier. — Nadia ”
Yuki · Sudan · August 2025
Read the full case study
Leonia
IndiaSiemens SIMATIC S7-400 PS 407 · 6ES7407-0DA01-0AA0

Siemens PS 407 Verified for an Indian Textile Plant

An Indian textile manufacturer asked Apter Power to verify Siemens SIMATIC S7-400 PS 407 module 6ES7407-0DA01-0AA0 by complete catalogue number, visible condition and packaging evidence before the next supply decision.

24/7Textile plant support
100%Inspected for Original & New product
“ Apter made our first overseas purchase of Siemens S7-1200 spares straightforward, with clear model confirmation and delivery arrangements. — Singh ”
Leonia · India · 9 October 2026
Read the full case study
Miya
ChinaQuality Inspection & Traceability

ISO 9001:2015 Quality Management Certification

Review the ISO 9001:2015 certificate for Apter Power, its certified scope, certificate number, validity, process-control purpose and the limits of management-system certification.

ISO 9001Certified quality system
TraceableDocumented order records
“ Certification matters only when the process is visible in everyday work—from the first requirement review to the final release. — Miya ”
Miya · China · August 2026
Read the full case study

Where this item is used

The nine industries we publish solutions for. Each links through to that industry page.

FAQs

Questions we actually get about this item. If yours is not here, put it in the message field above.

About this part

Why can Siemens 6ES7924-0CD00-0AB0 show an input voltage while the load stays off?

On Siemens 6ES7924-0CD00-0AB0, test the paired relay contact, external load supply, return conductor and field device.

Can 6ES7924-0CD00-0AB0 switch the same current at AC and DC voltages?

No. 6ES7924-0CD00-0AB0 has different documented AC and DC contact limits, so use the rating for the actual circuit.

How should a failed channel on Siemens 6ES7924-0CD00-0AB0 be isolated?

For Siemens 6ES7924-0CD00-0AB0, compare input voltage, relay continuity, load supply and field response with a working channel.

What prevents wiring errors when replacing 6ES7924-0CD00-0AB0?

Photograph and label every 6ES7924-0CD00-0AB0 input, contact, common and load conductor before removal.

Why does an inductive load shorten relay life on 6ES7924-0CD00-0AB0?

Without suitable suppression, 6ES7924-0CD00-0AB0 contacts interrupt stored coil energy that increases arcing and electrical wear.

Which identity details distinguish Siemens 6ES7924-0CD00-0AB0 from another relay block?

Confirm Siemens 6ES7924-0CD00-0AB0, eight 24 V DC inputs, eight normally open outputs and spring-terminal construction.

Can't find the part number you need?

We quote thousands of parts that never appear on this site — current, obsolete and hard to find. Send the number and we will tell you honestly whether we can get it.

Mon–Fri 09:00–18:00 GMT+8 · enquiries answered within 2 working hours

Talk to our team

An account manager works the enquiry through with you — checking the configuration before pricing, rather than sending a price list back.

Mon–Fri 09:00–18:00 GMT+8 · Xiamen, China

ISO 9001:2015 certified

Every part we supply meets industry standards and comes from a certified quality management system.

View certificate

You may also like

6ES7312-1AE13-0AB0
The 6ES7312-1AE13-0AB0 is a Siemens SIMATIC S7-300 CPU 312 with 32 KB work memory, 24V DC integrated power supply, MPI interface, and requires a micro memory card (MMC).
6GK7343-1GX31-0XE0
The Siemens 6GK7343-1GX31-0XE0 CP 343-1 Advanced links an S7-300 CPU to Industrial Ethernet as a PROFINET IO controller or device.
In stock
6ES7352-1AH02-0AE0
Siemens 6ES7352-1AH02-0AE0 is an FM 352 electronic cam controller that converts encoder position into high-speed track and digital-output switching for rotary or linear axes.
In stock
6ES7352-5AH01-0AE0
The Siemens 6ES7352-5AH01-0AE0 is an S7-300 FM352-5 Boolean processor that evaluates digital and encoder signals and drives eight high-speed current-sinking outputs.
In stock
6ES7352-1AH01-0AE0
Encoder position is evaluated by Siemens 6ES7352-1AH01-0AE0, an S7-300 FM 352 electronic cam controller that switches digital outputs at configured cam positions.
In stock
6ES7951-1KM00-0AA0
For SIMATIC S7-300 load-program storage, Siemens 6ES7951-1KM00-0AA0 is a 4 MB Flash EPROM memory card that retains controller software without power.
In stock
6ES7315-6TH13-0AB0
Siemens 6ES7315-6TH13-0AB0 is a CPU 315T-2 DP technology controller with 256 KB work memory, two PROFIBUS-capable interfaces, integrated technology I/O, and MMC load memory.
In stock
6ES7390-0AA00-0AA0
Siemens 6ES7390-0AA00-0AA0 is a SIMATIC S7-300 bus connector supplied as rack-bus connection hardware for an S7-300 module assembly.
In stock
6ES7953-8LF31-0AA0
Siemens 6ES7953-8LF31-0AA0 is a 3.3 V, 64 KB Flash-EPROM Micro Memory Card for compatible S7-300, C7, and ET 200 controllers.
In stock
6ES7313-1AD00-0AB0
Siemens 6ES7313-1AD00-0AB0 is an early SIMATIC S7-300 CPU 313 with 12 KB work memory and an integrated MPI communication interface.
In stock

Looking for a part-number suffix that is not listed? We quote thousands of Bently Nevada configurations that never appear on the site — send the part number.

Same kind of part from other manufacturers:

Product browsing history

Request a quote WhatsApp Chat