Features:
- Runs the S7-300 user program with 256 KB of integrated work memory.
- Separates MPI access from a configurable PROFIBUS DP master/slave channel.
- Extends the documented ambient range through the SIPLUS conformal-coated design.
Siemens 6AG1315-2AH14-7AB0 places CPU processing, communication coordination and station diagnostics in one S7-300 assembly.
Front indicators distinguish operating mode and bus-fault states, giving a local check before diagnostic-buffer entries are read through the engineering connection.
Integrated timers, counters and the hardware clock provide the execution resources used by the configured automation program.
The Siemens 6AG1315-2AH14-7AB0 SIPLUS S7-300 CPU 315-2 DP may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6AG1315-2AH14-7AB0 SIPLUS S7-300 CPU 315-2 DP Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
How Program Storage Is Organized
- Load Medium: The user program is held on the required SIMATIC Micro Memory Card before execution.
- Work Memory: Integrated work memory provides the active code and data area for CPU processing.
- Retention: Retentive behavior is assigned through the S7-300 memory configuration rather than a separate backup battery.
Programming and Station Access
- Programming Access: The MPI connector provides the programming-device path for 6AG1315-2AH14-7AB0.
- Station Communication: The same interface supports communication with other MPI nodes in the configured S7-300 station.
- Path Separation: Keeping MPI duties on the first port leaves distributed-I/O traffic available to the second interface.
Master and Slave Assignment
- Master Role: The second connector can be configured as a PROFIBUS DP master.
- Slave Role: A DP slave role is also available when the CPU must exchange data under another master.
- Configuration Effect: The selected role determines how distributed stations and cyclic data are organized in the hardware configuration.
SIPLUS Operating Boundaries
- SIPLUS Construction: Conformal coating is part of the SIPLUS construction for the complete order number.
- Temperature Range: The documented ambient operating range extends from -25 to 70 °C.
- Installation Boundary: Cabinet planning must retain the specified ventilation and IP20 installation boundary.