Supplied with every order

  • Commercial invoice and packing list
  • Nameplate and packaging photographs
  • 12-month Apter Power warranty
Need a specific document format for your import process? Say so in the enquiry and we will confirm before you order.

Recommended to use with 6ES7422-1HH00-0AA0

All in stock · Add one and it is quoted together with the model, one shipping cost.

6ES7422-1HH00-0AA0

Siemens 6ES7422-1HH00-0AA0 is an S7-400 SM 422 relay output module that switches sixteen isolated AC or DC load circuits from controller output commands.

In Stock Ships by Thursday, November 26 Fast Shipping Available
Dispatched within 24 hours of a confirmed order.
Nameplate and packaging photographs supplied before dispatch.
ISO 9001:2015 certified

Industry compliance and certified quality in every part we supply.

View certificate

Get a price for 6ES7422-1HH00-0AA0

6ES7422-1HH00-0AA0Siemens S7-400 SM 422 16-Channel Relay Output Module
Edit or add anything — monitor type, cable length, other part numbers.

Tell us which and we will shape the quote around it.

Attach a nameplate photo and an engineer will confirm the exact part number before quoting.

Answered within 2 working hours, Mon–Fri 09:00–18:00 GMT+8. Used only for this quotation.

Your Quote Request Has Been Received

Thank you. Our sales team will review your request and contact you shortly.

Ordering, delivery and after-sales

Your account managerNamed, start to finish

Your enquiry is picked up by a named account manager who checks the configuration before pricing and stays with the order through dispatch and after-sales. You are not passed round a shared inbox.

  • Direct email and WhatsApp for that person
  • Quotation signed by whoever prepared it
  • Same contact if anything needs sorting later

Enquiries are answered within 2 working hours, Mon–Fri 09:00–18:00 GMT+8.

Warranty12 months from shipment

Twelve months from date of shipment against functional defects under normal operating conditions. Because Apter Power is an independent supplier, the manufacturer’s own warranty does not apply — ours stands in its place, which on a discontinued part is the only cover there is.

If it arrives faulty or does not fitReturn authorisation same day

A written procedure, not a negotiation.

  • Report the fault within the 12-month warranty period
  • We issue a return authorisation the same working day
  • Return the unit within 14 days of reporting, in antistatic packaging where applicable
  • Replacement, repair or refund at our option, confirmed in writing
  • Return shipping on a confirmed warranty defect is at our cost

If it turns out to be a configuration mismatch rather than a fault, we help you identify the correct part instead of leaving you with the wrong one.

Pre-dispatch inspectionWhat we check — and what we don’t

Checked:

  • Part number and revision read from the unit nameplate, and photographed
  • Outer packaging and seals inspected and photographed
  • Connector threads and mounting stud checked for damage
  • Quantity and accessory contents verified against the packing list

Not checked: no powered functional or calibration test is performed on this item; sensitivity and frequency response are not re-certified by Apter Power; no hazardous-area certification is issued by us. If you need a functional test report before shipment, ask when you request the quote and we will confirm whether it is possible and what it adds to the lead time.

Our quality management is certified to ISO 9001:2015. More usefully, the scope above is published rather than summarised as “tested and approved” — nothing is implied that we did not do.

Shipping, customs and documentsDispatch in 24h · 170+ countries

Dispatch within 24 hours of a confirmed order for items held in stock. DHL, FedEx and UPS express to 170+ countries, typically 3–6 working days door to door; tracking is emailed the day the order leaves us. Shipping method and cost are itemised on every quotation and never added afterwards.

Most delays on an international spare are paperwork rather than freight, so the documents are prepared before the parcel leaves:

  • Commercial invoice and packing list on every shipment
  • Certificate of Origin prepared on request — ask at enquiry stage
  • HS code stated on the quotation, not discovered at clearance
  • We work to your broker’s format if you tell us what it is
PaymentTelegraphic transfer only

We accept payment by telegraphic transfer (T/T) only. Bank details appear on the pro-forma invoice and nowhere else — we never send revised bank details by email after quoting. If you receive a message claiming our account has changed, call +86 15359408275 before paying.

How to orderSend the part number

Send the enquiry above, or email the part number, quantity and destination country. In-stock items show a live quantity; where a part is not held we show "Ask" and confirm availability from our supplier network before quoting, so you are never quoted a lead time we cannot meet.

Discover the experience, people and global sourcing expertise behind Apter Power. About us »

Technical specifications

 set by the part-number suffix dotted  awaiting confirmation against the OEM datasheet

Part identification

Manufacturer
Siemens
Part Number
6ES7422-1HH00-0AA0
Product Family
Siemens Simatic S7-400
Product Type
S7-400 SM 422 16-Channel Relay Output Module
Stock
1
Weight
1.9379 lbs (0.879 kg)
Estimated shipping dimensions
23.10x29.90x3.80cm
Tariff Code
85389091
Country of origin
Germany
Place of shipment
Xiamen,Fujian,China

More information

Features:

  • Switches sixteen external AC or DC circuits through isolated relay contacts.
  • Organizes outputs as eight groups of two so each pair retains its load-voltage path.
  • Indicates each commanded output state with a dedicated green LED.
Controller output bits operate the relays while external sources provide the actual load energy.

Group current, ambient temperature and ventilation determine how many loads can switch simultaneously.

LED command, relay-contact voltage and device response are checked together during diagnosis.

The Siemens 6ES7422-1HH00-0AA0 S7-400 SM 422 16-Channel Relay Output Module may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6ES7422-1HH00-0AA0 S7-400 SM 422 16-Channel Relay Output Module Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Keeping each isolated relay pair with its load source

  • Eight pairs: Sixteen channels are divided into eight groups of two.
  • External source: Each pair switches the connected AC or DC load voltage.
  • Return path: The field return remains with the same group circuit.
  • Protection: Branch protection is coordinated with conductor and contact current.

Relating switching rate to the connected device

  • Resistive load: Resistive circuits use the documented higher switching-frequency limit.
  • Inductive load: Coils switch at the lower allowed rate and use suitable suppression.
  • Lamp load: Lamp inrush and wattage are checked against the relay-contact limit.
  • Minimum current: Very small loads remain above the documented reliable switching value.

Applying group-current limits inside the rack

  • At 40 degrees: Each output group can carry the documented higher combined current.
  • At 60 degrees: The limit drops without the specified fan condition.
  • Fan condition: Documented ventilation permits the higher group-current value at 60 degrees.
  • Load distribution: Simultaneous loads are spread so no relay pair exceeds its group limit.

Separating command, contact and field faults

  • Controller bit: The program command is checked first.
  • Green LED: The channel LED confirms the module received the output state.
  • Contact voltage: Measurement across the relay path shows whether the contact switched.
  • Field response: External supply, return and actuator are checked when the contact is correct.

Description

Siemens 6ES7422-1HH00-0AA0 is a SIMATIC S7-400 SM 422 relay output module with sixteen isolated switching channels. Controller output bits operate relay contacts that pass external AC or DC load power to field devices.

The channels of 6ES7422-1HH00-0AA0 are arranged as eight isolated groups of two outputs. Each group carries its own external load circuit, so voltage source, return path and protective device remain associated with the correct relay pair.

Contact duty on 6ES7422-1HH00-0AA0 depends on load type and operating rate. Resistive circuits can switch faster than inductive or lamp loads, while group-current limits decrease at higher ambient temperature unless the documented fan condition is provided.

A green LED for every output on 6ES7422-1HH00-0AA0 shows the commanded channel state, but the relay contact and external supply determine whether the load is energized. Commissioning therefore compares the LED, contact voltage and field-device response.

Case studies

Order from our published case studies. Each one names the customer situation, the parts involved and what changed.

Jim
ChinaSGS inspection

SGS Verification for Global Automation Procurement

Documented third-party inspection helps procurement teams evaluate supplier processes, product conformity and pre-shipment evidence before cross-border automation orders move forward.

SGS ReviewIndependent evidence
4 StepsClear verification process
“ Verification should show what was checked and how it matches the buyer’s requirements. — Jim ”
Jim · China · 2026
Read the full case study
May
Malaysia3500/22M

Malaysia Customer Collects Bently Nevada 3500/22-01-02-00 After On-Site Inspection

After equipment downtime, a Malaysian customer travelled to Xiamen to inspect and collect a Bently Nevada 3500/22-01-02-00. The unit could be tested and put into use the next day, helping shorten factory downtime and reduce associated losses.

5On-site checks
1 dayReady for testing
“ Apter responded quickly and had the right Bently Nevada module ready for us to inspect and collect. — Shah ”
May · Malaysia · October 2026
Read the full case study
May
ChinaBently Nevada

Bently Nevada Audit: Zero Discrepancies, USD 25,000 Order

A customer verified Bently Nevada accelerometers, cables and 3500/22M modules at Apter Power. Zero discrepancies led to a USD 25,000 order paid three hours later.

3 hrsOrder to payment
$25,000Follow-up order
“ Apter Power gave us the evidence to approve the expansion with confidence. — Customer procurement manager ”
May · China · 2026
Read the full case study

Where this item is used

The nine industries we publish solutions for. Each links through to that industry page.

FAQs

Questions we actually get about this item. If yours is not here, put it in the message field above.

About this part

Why can Siemens 6ES7422-1HH00-0AA0 show a green LED while the actuator remains off?

Siemens 6ES7422-1HH00-0AA0 LEDs show commands; verify the external load supply, relay contact, return path and actuator circuit.

How should group current be checked on 6ES7422-1HH00-0AA0 in a hot cabinet?

For 6ES7422-1HH00-0AA0, total both outputs in each pair and apply the documented ambient and fan-dependent group limit.

What causes rapid relay wear on Siemens 6ES7422-1HH00-0AA0?

Siemens 6ES7422-1HH00-0AA0 relay life falls with excessive switching frequency, inductive energy, lamp inrush or unsuitable suppression.

Can different load voltages be mixed across 6ES7422-1HH00-0AA0?

The isolated pairs of 6ES7422-1HH00-0AA0 can use documented AC or DC circuits when each group keeps its own source and return.

Why might a very small load fail to switch reliably on Siemens 6ES7422-1HH00-0AA0?

Check whether the Siemens 6ES7422-1HH00-0AA0 load current remains above the documented 11 mA minimum and whether contacts are contaminated.

Which details should be preserved when rewiring 6ES7422-1HH00-0AA0?

Record 6ES7422-1HH00-0AA0 channel numbers, relay-pair groups, load voltages, protective devices, commons and suppression components.

Can't find the part number you need?

We quote thousands of parts that never appear on this site — current, obsolete and hard to find. Send the number and we will tell you honestly whether we can get it.

Mon–Fri 09:00–18:00 GMT+8 · enquiries answered within 2 working hours

Talk to our team

An account manager works the enquiry through with you — checking the configuration before pricing, rather than sending a price list back.

Mon–Fri 09:00–18:00 GMT+8 · Xiamen, China

ISO 9001:2015 certified

Every part we supply meets industry standards and comes from a certified quality management system.

View certificate

You may also like

6ES7414-4HJ04-0AB0
6ES7414-4HJ04-0AB0 is a SIMATIC S7-400H CPU 414H central unit for S7-400H and S7-400F/FH systems, featuring 4 interfaces (1 MPI/DP, 1 DP, and 2 for sync modules) and 1.4 MB memory (700 KB data / 700 KB program).
In stock
6ES7 964-2AA04-0AB0
The Siemens 6ES7964-2AA04-0AB0 is a DP master interface module designed specifically for the SIMATIC S7-400 series.
6ES7414-5HM06-0AB0
The 6ES7414-5HM06-0AB0 is a Siemens SIMATIC S7-400H series CPU 414-5H central processing unit, designed for high-availability fault-tolerant automation systems.
6ES7414-3EM07-0AB0
Siemens 6ES7414-3EM07-0AB0 CPU 414-3 PN/DP Central Processing Unit: 4 MB work memory, MPI/DP, two-port PROFINET, and one IF 964-DP option slot.
In stock
6ES7414-3FM07-0AB0
Siemens 6ES7414-3FM07-0AB0 CPU 414F-3 PN/DP Fail-Safe Central Processing Unit: 4 MB work memory with fail-safe CPU functions, MPI/DP, PROFINET, and IF 964-DP support.
In stock
6ES7407-0RA01-0AA0
The Siemens 6ES7407-0RA01-0AA0 PS 407 converts a wide-range AC or DC input into 5 VDC/20 A and 24 VDC/1 A rails for an S7-400 rack.
In stock
6GK7443-1GX20-0XE0
Using five Ethernet ports, Siemens 6GK7443-1GX20-0XE0 is a CP 443-1 Advanced communications processor that links an S7-400 CPU with Industrial Ethernet and PROFINET IO devices.
In stock
6ES7952-1AP00-0AA0
Siemens 6ES7952-1AP00-0AA0 is a long-format 8 MB RAM memory card that expands load memory for compatible SIMATIC S7-400 CPUs.
In stock
6ES7478-2CA00-0AC0
Siemens 6ES7478-2CA00-0AC0 is the SIMATIC M7-400 ATM478 expansion module for one short AT-format card. It supplies and monitors the AT rails while passing the M7 backplane through paired 120-pin connectors.
In stock
6GK7443-1EX41-0XE0
Siemens 6GK7443-1EX41-0XE0 is a CP 443-1 Advanced communications processor with four RJ45 ports, PROFINET IO controller services, and Industrial Ethernet protocols.
In stock

Looking for a part-number suffix that is not listed? We quote thousands of Bently Nevada configurations that never appear on the site — send the part number.

Same kind of part from other manufacturers:

Product browsing history

Request a quote WhatsApp Chat