Features:
- Twenty-four output channels command safety actuators through coupling relays.
- One readback input per output lets the processor supervise the external path.
- Channel LEDs distinguish a high command from the documented flashing fault state.
The FUM360 belongs to the TELEPERM XP AS 620 F output architecture.
Command and feedback signals remain paired for channel-level monitoring.
The documented redundant layout uses two FUM360 modules with the specified MFX53 component.
The Siemens 6DP1360-8BA TELEPERM XP FUM360 Fail-Safe Output Module may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6DP1360-8BA FUM360 Module Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Relating actuator commands to coupling relays
- Channel command: Each processor command is assigned to one FUM360 output.
- Relay interface: The output drives the documented coupling-relay path rather than the actuator directly.
- Actuator circuit: The relay contact transfers the command into the external safety load circuit.
- Channel count: Twenty-four monitored output paths share the module assembly.
Comparing each command with its returned state
- Paired feedback: One readback input is associated with each output channel.
- State comparison: The AS 620 F logic can compare the command with the returned relay-circuit condition.
- Fault indication: A flashing channel LED identifies the documented discrepancy or fault state.
- Wiring inspection: Command and readback conductors must remain assigned to the same channel.
Using local LEDs during circuit diagnosis
- High output: A steady red LED shows the channel command in its high state.
- Fault pattern: A 2 Hz flashing red LED marks the stated channel fault behavior.
- Channel mapping: Twenty-four indicators correspond to the twenty-four output paths.
- Processor diagnosis: Local indication supports, but does not replace, evaluation in the AS 620 F system.
Reproducing the documented safety architecture
- Module pair: Two FUM360 assemblies form the specified paired output arrangement.
- MFX53 component: The documented MFX53 participates in the approved configuration.
- System responsibility: The safety function depends on the complete AS 620 F architecture.
- Exact article: The 8BA order code must be matched before module placement or wiring.