Features:
- Maintains independent programming for four dynamic and two speed channels.
- Offers standard, separate-circuit and safety architectures within the MPC4 family.
- Provides programmable Alert, Danger and OK behavior with visible front-panel indication.
The exact ordering reference is 200-510-078-115, within the six-channel VM600 MPC4 protection-card range.
The processor can pair order-tracked phase with amplitude, apply adaptive alarm limits and pass raw buffered signals to analysis equipment without interrupting the protection calculation.
Before installation, identify the required MPC4 variant from the full nameplate and project file. Validate IOC4T location, sensor bias and set-point ownership before any hot-swap action.
Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Vibro-Meter 200-510-078-115:
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Supervises shaft relative vibration and casing vibration in central VM600 racks.
- Uses tachometer references for phase-stable analysis of rotating components.
- Supports protective monitoring on turbines, motors, fans and balance-of-plant machinery.
- Integrated supplies support compatible IEPE accelerometers and proximity-measurement systems.
- The selected sensor chain must remain within the card’s configured power and signal limits.
- Channel health depends on matching sensor bias, polarity and conditioner type before enabling protection.
- Two programmable tachometer channels provide speed and phase references.
- Amplitude and phase are evaluated simultaneously against rotating orders.
- Tracked measurements remain associated with their configured dynamic channels during speed changes.
- Use the correct MPC4 architecture when a separate-circuits or safety application is specified.
- Alarm set points and channel bypasses must follow the approved machinery-protection procedure.
- Hot insertion is permitted only when VM600 rack conditions and site-safety controls are satisfied.