Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power supports 200-570-000-111 quotation, documentation, sourcing, and system-fit review.

200-570-000-111

/ 4.9
1001 reviews | Need a Specific Revision?
Vibro-Meter 200-570-000-111 is a VM600 RLC16 rear relay card providing sixteen configurable alarm relays with changeover contacts.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for 200-570-000-111
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 200-570-000-111

  • Manufacturer:
    Vibro-Meter
  • Part Number:
    200-570-000-111
  • Product Family:
    VM600 Machinery Protection System
  • Product Type:
    16-Relay Alarm Card
  • Stock:
    1
  • Module type:
    VM600 RLC16 relay card
  • Relay count:
    16
  • Relay labels:
    RL1 to RL16
  • Contacts per relay:
    COM, NC and NO
  • Contact rating:
    1250 VA, 250 VAC, 5 AAC
  • Typical operate time:
    8 ms
  • Typical bounce time:
    6 ms
  • Open-contact dielectric strength:
    1000 VAC
  • Contact-to-coil dielectric strength:
    4000 VAC
  • Mechanical life:
    15 × 10⁶ operations
  • Electrical life:
    >10⁵ operations
  • Relay state selection:
    Normally energized or de-energized by jumper
  • Field connectors:
    J1, J2 and J3 screw terminals
  • Rack location:
    Rear of VM600 rack
  • Backplane interface:
    Single rack backplane connector
  • Alarm source:
    VM600 backplane digital alarm signals
  • Primary function:
    Additional alarm relays
  • System family:
    VM600 machinery monitoring
  • Weight:
    0.705 lbs (0.32 kg)
  • Estimated shipping dimensions:
    2 x 12.5 x 26.1 cm
  • Tariff Code:
    8537101190
  • Country of origin:
    Switzerland
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Applications Control Configuration & Programming Protection

Features:

  • Supplies sixteen relays, each with COM, NC and NO field contacts.
  • Allows normally energized or normally de-energized operation by channel jumper.
  • Accepts alarm commands from the VM600 rack backplane in a rear-mounted card.
The current configuration is RLC16 ordering number 200-570-000-111 for additional VM600 alarm contacts.

Its relay bank separates rack alarm logic from external annunciators, interposing devices and shutdown circuits.

Before installation, compare contact voltage, VA, coil philosophy, terminal plan and all jumper positions with the approved cause-and-effect drawing.

Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Vibro-Meter 200-570-000-111: Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Adds plant alarm and trip contacts when the relays on protection-card pairs are insufficient.
  • Fans VM600 Alert, Danger or equipment-status signals into independent annunciation circuits.
  • Provides selectable fail-safe relay behavior for rotating-equipment protection cabinets.
  • Each of the sixteen relay channels presents common, normally closed and normally open contacts.
  • Contacts are rated to 1250 VA at up to 250 VAC and 5 AAC within the specified load envelope.
  • Mechanical life is specified at fifteen million operations, while electrical life depends on the switched load.
  • VM600 backplane alarm states can be assigned to relay channels through the system configuration.
  • Normally energized selection supports de-energize-to-trip philosophies where required by the design.
  • Terminal groups J1, J2 and J3 distribute the sixteen relay contact sets to field wiring.
  • Open-contact dielectric strength is specified at 1000 VAC.
  • Contact-to-coil insulation withstands 4000 VAC under the stated test conditions.
  • Inductive suppression must be selected externally so stored energy does not damage the contacts.
Description
Vibro-Meter 200-570-000-111 Sixteen isolated electromechanical channels convert VM600 backplane alarm states into field-ready relay contacts. Each channel provides common, normally closed, and normally open connections, giving protection logic a dedicated route to annunciators, interlocks, and external trip circuits.

Individual energization choices allow contact behavior to follow the plant fail-safe philosophy instead of imposing one common mode on the whole card. Alarm assignments can be distributed across terminal groups, supporting selective shutdown, alarm fan-out, or interface duties for different machine trains.

Contact life depends on what is switched, not only on mechanical endurance. Load voltage, current, inductive energy, suppression method, conductor separation, jumper position, and terminal numbering should be reviewed channel by channel before an existing relay map is transferred.
Alternative Names
200-570-000-111 200 570 000 111 200570000111 Vibro-Meter 200-570-000-111 Meggitt RLC16 200-570-000-111 VM600 RLC16 200-570-000-111 200-570-000-111 16-Relay Card
Technical notes
200-570-000-111 relay jumpers define normal energization; document all sixteen positions and isolate inductive loads before moving field wiring.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How many independent contacts does 200-570-000-111 provide?
The RLC16 card contains sixteen relays with COM, NC and NO connections for each channel.
What sets the fail-safe behavior of 200-570-000-111?
A channel jumper selects normally energized or normally de-energized relay operation.
Where does 200-570-000-111 fit in a VM600 alarm design?
It adds hardware contacts for plant annunciation and trip circuits when local card-pair relays are insufficient.
Which details are checked before quoting 200-570-000-111?
Apter Power confirms the exact code, contact-duty requirement, condition, quantity, destination and delivery schedule.
Can 200-570-000-111 replace a relay card without checking jumpers?
No. Reversing the normal-energization selection can invert the intended fail-safe action.
What drawings support a 200-570-000-111 field review?
Provide the cause-and-effect matrix, relay assignment list, terminal schedule, load type and suppression arrangement.